User's Manual
Table Of Contents
- Introduction
- What's New
- What's New in Release J.3
- Avalon CL Transducer System
- Support For Use of Maternal Cableless Measurement Devices
- Maternal Temperature Measurement
- Manually Entered Maternal Temperature Measurements
- New Design for the User Interface
- New SmartKeys
- Coincidence INOP Tone
- Increased Internal Back-up Memory
- USB Interface
- Flexible Nurse Call Interface
- DHCP Support
- Data Export Support
- NBP Configurable Measurement Sequence
- Alarms Enhancements
- Alarm Reminder
- Auto Free
- What's New in Release G.0
- Battery Option and Patient Transport Improvements for the Avalon FM20 and FM30
- Maternal Pulse from Toco MP Transducer
- Non Stress Test (NST) Analysis as Clinical Decision Support (CDS) Application
- FHR Sound Source
- FHR Numeric Display
- Improved FHR and DFHR Label Concept
- New SmartKeys
- Trace Separation On/Off Operation
- NBP
- Alarms
- CCV INOP
- New Demographic Fields
- Recorder
- Stored Data Recording
- FHR Sound Volume
- Avalon CTS
- What's New in Release J.3
- Basic Operation
- Supported Measurements
- Avalon FM20 and FM30
- Avalon FM40 and FM50
- Avalon CL Transducer System
- Getting to Know Your Avalon FM20/FM30
- Getting to Know Your Avalon FM40/FM50
- Transducers
- Getting to Know Your Avalon CL
- Cableless Transducers
- Radio Range of CL Transducers
- The CL transducers have a operating range around the base station of at least 70 m in the line of sight. Obstructions as walls, metal doors, elevators and other environment structures can lead to signal loss. The Tele symbol indicator and the Tele In...
- Connector Cap for the CL Toco+ MP Transducer
- Cableless Transducer LED Indication
- CL Transducer Battery
- Audio Signal CL Transducers
- CL Pods
- Operating and Navigating
- Operating Modes
- Automatic Screen Layouts
- Settings
- Preparing to Monitor
- Switching the Monitor to Standby
- After Monitoring
- Disconnecting from Power
- Power On/Power Off Behavior
- Monitoring After a Power Failure
- Troubleshooting
- FM20/30 Battery Option
- Alarms
- Patient Alarms and INOPs
- Admitting and Discharging
- Non-Stress Test Timer
- Non-Stress Test Report
- Cross-Channel Verification (CCV)
- Monitoring FHR and FMP Using Ultrasound
- Technical Description
- Limitations of the Technology
- Misidentification of MHR as FHR
- What You Need
- Cableless Monitoring - Important Considerations
- Preparing to Monitor
- Selecting Fetal Heart Sound
- Changing the Fetal Heart Sound Volume
- Fetal Movement Profile
- Troubleshooting
- Additional Information
- Testing Ultrasound Transducers
- Monitoring Twin FHRs
- Monitoring Triple FHRs
- Fetal Heart Rate Alarms
- Monitoring Uterine Activity Externally
- Monitoring Uterine Activity Internally
- Monitoring FHR Using DECG
- Monitoring Noninvasive Blood Pressure
- Introducing the Oscillometric Noninvasive Blood Pressure Measurement
- Preparing to Measure Noninvasive Blood Pressure
- Starting and Stopping Measurements
- Enabling Automatic Mode and Setting Repetition Time
- Enabling Sequence Mode and Setting Up The Sequence
- Choosing the Alarm Source
- Assisting Venous Puncture
- Calibrating NBP
- Troubleshooting
- Monitoring Maternal Temperature
- Monitoring SpO2
- Monitoring Maternal Heart / Pulse Rate
- Printing the ECG Waveform
- Paper Save Mode for Maternal Measurements
- Recovering Data
- Care and Cleaning
- Maintenance
- Accessories and Supplies
- Specifications and Standards Compliance
- Environmental Specifications
- Physical Specifications
- Performance Specifications
- Recorder Specifications
- Compatible External Displays: FM40/FM50 Only
- Manufacturer's Information
- Trademark Acknowledgment
- Regulatory and Standards Compliance
- Safety and Performance
- Safety Tests Fetal Monitor
- Electromagnetic Compatibility (EMC)
- EMC Testing
- Reducing Electromagnetic Interference
- System Characteristics
- Electromagnetic Emissions and Immunity
- Electromagnetic Immunity
- Radio Compliance Notice
- Finding Recommended Separation Distances
- Recommended Separation Distances from Other RF Equipment
- Radio Frequency Radiation Exposure Information
- Environment
- Monitoring After a Loss of Power
- ESU, MRI and Defibrillation
- Cardiac Pacemakers and Electrical Stimulators
- Fast Transients/Bursts
- Symbols on the System
- Default Settings Appendix
19 Monitoring Maternal Temperature
213
Status Screens
The thermometer performs an internal test at every start-up to verify that the system components are
functioning properly. It measures the ambient temperature. During start-up and measurement, the
thermometer screens communicate the current status.
Making a Temperature Measurement
WARNING
Inaccurate measurement results can be caused by:
• incorrect application of the thermometer.
• anatomical variations in the ear.
• build up of earwax in the ear.
• excessive patient movement during the measurement.
• absent, defective or soiled probe covers.
• probe covers other than the specified probe covers.
1 Ensure that the base station is connected via the appropriate cable to the connector on the
monitor.
2 Remove the thermometer from the base station.
The thermometer is latched to the base station to avoid an accidental fall when the base station is
moved. To pick up the thermometer from the base station move it slightly up and then lift it from
the base station to release the latch.
3 Press the eject key on the thermometer to discard any probe that may have been left on the
thermometer from a previous use.
Images Description
Ambient Temperature above specified range
Ambient Temperature below specified range
System errors
System error 12 - there is a problem with the settings. Contact your
service personnel to have them check the settings and reset them, if
necessary.
If the display shows any other system error, then reset the thermometer by
picking up a probe cover. If the system error does not clear, contact your
service personnel.