Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Getting Started
- 3 Basic Operation
- 4 Sonde Menu
- 5 PC6000 Software
- 6 Principles of Operation
- 7 Maintenance
- 8 Troubleshooting
- 9 Communication
- Appendix A Health and Safety
- Appendix B Require Notice
- Appendix C Warranty and Service Information
- Appendix D Accessories and Reagents
- Appendix E Application Note
- Appendix F Solubility and Pressure/Altitude Tables
- Appendix G Sensor and Sonde Storage Recommendations
- Appendix H Turbidity Measurements with the 6000UPG
- Appendix I System Errors and Warnings
5-11
Select the Scaling Info menu option
+------------------------------------------------------------------------------+
¦ Sonde File Setup Real-Time Exit YSI PC6000 ¦
¦------------------------------------------------------------------------------¦
¦ ¦
¦ ¦
¦ ¦
¦ +--------------------------------------------------------+ ¦
¦ ¦ Filename: SRUNS62O.DAT ¦ ¦
¦ ¦--------------------------------------------------------¦ ¦
¦ ¦ MODIFY ¦ VIEW ¦ SYSTEM ¦ ¦
¦ ¦------------------+------------------+------------------¦ ¦
¦ ¦ Parameters... ¦ Header ¦ Print Report ¦ ¦
¦ ¦ Control Info... ¦ Report ¦ Print Plot ¦ ¦
¦¦Scaling Info... ¦ Plot ¦ Definitions... ¦ ¦
¦ ¦ ¦ Statistics ¦ Export ¦ ¦
¦ +--------------------------------------------------------+ ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦------------------------------------------------------------------------------¦
¦ View or change scaling technique, minima, and maxima ¦
+------------------------------------------------------------------------------+
There are three scaling options.
+------------------------------------------------------------------------------+
¦ Sonde File Setup Real-Time Exit YSI PC6000 ¦
¦------------------------------------------------------------------------------¦
¦ Scaling technique: automatic ¦
¦ Copy default to manual ¦
¦ Copy automatic to manual Default Manual Automatic ¦
¦ Scaling Scaling Scaling ¦
¦ Parameter Units Minimum Maximum Minimum Maximum Minimum Maximum ¦
¦ ------------ -------- ------- ------- ------- ------- ------- ------- ¦
¦ Temperature C -5 45 -5 45 -5 45 ¦
¦ Specific Cond mS/cm 0 235 0 235 0 235 ¦
¦ DO mg/L 0 20 0 20 0 20 ¦
¦pH 214214214¦
¦ ORP mV -1000 1000 -1000 1000 -1000 1000 ¦
¦ Battery volts 0 30 0 30 0 30 ¦
¦ Turbidity NTU 0 1000 0 1000 0 1000 ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦ ¦
¦------------------------------------------------------------------------------¦
¦ Select scaling technique (default, manual, automatic) ¦
+------------------------------------------------------------------------------+
Default scaling offers fixed limits. These limits correspond to the range of each parameter as
defined by the sensor specifications, so your plot will always fit within these limits.
Manual scaling allows you to enter custom limits for each parameter.
Automatic scaling. The computer scans the data file and determines its limits, then displays those
limits on the plot.
NOTE: When entering a scaling technique, you need only type the first letter of the desired
technique and press Enter. PC6000 will fill in the rest.