How to Use This Reference Manual The CL5/CL3/CL1 Reference Manual (this document) allows you to search for terms and take advantage of links in the text. Searching for terms To search for a term, use the search function of the software you’re using to view this document. If you’re using Adobe Reader, enter the term in the search box and press the key of your computer keyboard to search for occurrences of that term.
Contents Contents EQ and Dynamics ..................................................................... 56 About EQ and dynamics ......................................................................................... Using EQ ................................................................................................................ Using dynamics ...................................................................................................... Using the EQ or Dynamics libraries ................
Contents Graphic EQ, effects, and Premium Rack ............................... 114 About the virtual rack .......................................................................................... Virtual rack operations ......................................................................................... Graphic EQ operations......................................................................................... About the internal effects...............................................................
Function Tree Function Tree SEND TO/SEND FROM TO STEREO/MONO Page numbers in parentheses ( ) are the page numbers of the Owner’s Manual (booklet).
Function Tree SETUP CH JOB 158 CH LINK MODE 71 CREATE KEY 160 DCA GROUP ASSIGN 64 SAVE KEY 165 MUTE GROUP ASSIGN 66 LOGIN 161 RECALL SAFE MODE 88 SAVE/LOAD 177 CH COPY MODE 73 WORD CLOCK/SLOT 198 CH MOVE MODE 74 CH DEFAULT MODE 76 USER LEVEL/CREATE USER KEY CASCADE IN/OUT PATCH OUTPUT PORT MIDI/GPI 200, 202 18 149, 221 MIDI SETUP 150 PROGRAM CHANGE 152 CONTROL CHANGE 155 GPI 222 FADER START 225 BUS SETUP 202 CONSOLE LOCK 175 DATE/TIME 204 NETWORK 205 DANTE SETU
SELECTED CHANNEL section 2. SELECTED CHANNEL section This chapter explains how to use the SELECTED CHANNEL section and the SELECTED CHANNEL VIEW screen to control the selected channel. Press one of the knobs in the SELECTED CHANNEL section. Press a knob in the SELECTED CHANNEL section to display the SELECTED CHANNEL VIEW screen for the currently-selected channel.
SELECTED CHANNEL section SELECTED CHANNEL VIEW screen If the destination bus channels are two mono channels: 1 2 3 1 SEND knob Sets the send level to the corresponding bus. 2 PRE indicator Indicates the send point of the corresponding bus. If the PRE button on the MIX SEND 8ch screen is turned ON, this PRE indicator will be turned on. 3 ON button Switches the send signal to the corresponding bus on or off.
SELECTED CHANNEL section ■ GAIN/PATCH field This field enables you to make HA (head amp) analog gain settings, and view the operational status of the head amp. 1 GAIN knob Sets the analog gain of the head amp. For a channel to which the head amp has not been patched, a gray circle appears, instead of the knob. Press the knob to open the GAIN/PATCH 1ch popup window. 1 If the Gain Compensation function is turned on, an indicator appears, showing the level of the signal output to the audio network.
SELECTED CHANNEL section ■ EQ parameter field This field displays the 4-band EQ parameter settings. ■ EQ graph field This field graphically indicates the approximate response of the EQ. Press this field to open the HPF/ EQ 1ch popup window, in which you can set the attenuator, HPF and EQ. 1 Q knob Specifies the Q for each band. If the HIGH band filter type is set to LPF or H. SHELF (highshelving), or the LOW band filter type is set to L. SHELF (lowshelving), the Q knob will not be displayed.
SELECTED CHANNEL section ■ INSERT field This field enables you to make insert settings. ■ FADER field This field enables you to view and make settings for the channel on/ off status and the level. 1 1 Popup button 2 ON button 4 Displays the current level. Use the faders on the top panel to set the levels. 3 Displays the current level setting by numerical value. If the signal is clipping at any point in the channel, the ΣCLIP indicator will light.
Centralogic section Centralogic section Operations in the Centralogic section Follow the steps below to perform operations in the Centralogic section. This chapter explains how to use the Centralogic section and the OVERVIEW screen to simultaneously control up to eight channels. 1. About the Centralogic section Use the Bank Select keys in the Centralogic section to select the channels or DCA groups that you want to control. When you press a Bank Select key, the LED of that key will light.
Centralogic section ■ GAIN/PATCH field This field enables you to make HA (head amp) analog or digital gain settings and view the operational status of the head amp. The view and the function of the controllers in this field vary depending on the type of the selected channel. OVERVIEW screen If the head amp is patched: 1 GAIN knob 2 3 4 1 Sets the analog gain of the head amp.
Centralogic section ■ INPUT DELAY field This field displays the delay status for the input channel. If an output channel has been selected, this field will be blank. Press this field to open the INPUT DELAY 8ch popup window. ■ SEND field This field displays the send level, send on/off status, and pre/post settings for 16 buses. To select the 16 destination buses, use the [MIX 1–16] or [MIX 17–24/MATRIX] key in the SELECTED CHANNEL section on the panel.
Centralogic section ■ TO STEREO/MONO field This field displays the on/off status and pan/balance setting of the signal sent to the STEREO/MONO bus. If you press this field, the knob will be assigned to the corresponding knob in the Centralogic section. If you press the field once again, the TO STEREO/MONO 8ch popup window will appear. This field varies depending on the type of the selected channel.
Input and output patching Input and output patching Input patching CL series consoles and I/O devices feature two types of patching: Dante audio network patching and CL console internal patching. For Dante audio network patching, you will use the DANTE INPUT PATCH popup window. In this window, you can patch CL console and I/O device inputs. Sixty-four (64) channels can be input from a Dante audio network to a CL series console.
Input and output patching Changing the output patch settings In the PATCH/NAME popup window you can change the channel name, icon, and output port assigned to each output channel. The window includes the following items. To change the patching, you can either select the output port that will be the output destination of each output channel, or you can select the output channel that will be the output source for each output port. 3 4 5 Selecting the output port for each output channel 1.
Input and output patching 5 Channel name edit box Selecting the output channel for each output port Indicates the currently-specified channel. Press the inside of this box to enable the NAME tab at the bottom of the screen. The SOFT KEYBOARD popup window will appear, enabling you to edit the channel name. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. OUTPUT PORT button 6 Category select list Selects the type of the port you want to display on the screen.
Input and output patching 6 DELAY button In the OUTPUT PORT popup window, you can assign the source channel for each output port. This popup window includes the following items. Switches the output port delay on or off. 2 7 Ø (Phase) button Switches the phase of the signal assigned to the output port between normal phase and reverse phase. 1 3 4 8 GAIN knob Adjusts the output gain of the output port.
Input and output patching 5. The CH SELECT popup window will appear. This popup window includes the following items. Use the channel select tabs and the channel select buttons to select the source channel, and press the CLOSE button. You will return to the OUTPUT PORT popup window. NOTE If PATCH CONFIRMATION is ON, a confirmation dialog box will appear when you attempt to change the patch settings.
Input and output patching In the PATCH/NAME popup window you can view and change the channel name, icon, channel color, and input port assigned to each input channel. 2 • EFFECT RACK......... FX1L(A)–FX8R(B) • PREMIUM RACK.... PR1L(A)–PR2R(B) 3 5 Input port select buttons Assign an input port to the currently-selected input channel. 6 Tabs 1 Enable you to switch between items. 3.
Input and output patching 3 INSERT ON/OFF button Inserting an external device into a channel Switches the insert on or off. To change the currently-selected insert point, press one of the three blocks that does not contain any buttons. If desired, you can insert an effect processor or other external device into the signal path of an INPUT, MIX, MATRIX, STEREO, or MONO channel.
Input and output patching 4. INSERT/DIRECT OUT popup window (8ch) 1 Access either the one-channel or the eight-channel INSERT/DIRECT OUT popup window, and then press the INSERT OUT button. The PORT SELECT popup window will appear, allowing you to select the output port used for insert-out. The window includes the following items. 2 3 4 2 1 1 Channel select button Selects the channel to set. The channel icon, color, and number appear on the button.
Input and output patching 5. 6. Directly outputting an INPUT channel Use the category and the output port select buttons to specify the output port that will be used as insert-out, and press the CLOSE button. You will return to the INSERT/DIRECT OUT popup window. The signal of an INPUT channel can be output directly from an OUTPUT jack on the I/O device, from the desired OMNI OUT jack, or from the output channel of a desired slot. Press the INSERT IN button.
Input and output patching 4. 2 DIRECT OUT PATCH button Press this button to open the PORT SELECT popup window, in which you can select a Direct Out output port. The name of the currently-selected port appears on the button. 3 DIRECT OUT ON button Access either the one-channel or the eight-channel INSERT/DIRECT OUT popup window, and press the DIRECT OUT popup button. The PORT SELECT popup window will appear, allowing you to select the output port used for direct output.
Input and output patching 6. Recording or playing back using DAW on a computer Press the DIRECT OUT ON/OFF button to turn it ON. In this state, direct output is enabled. Adjust the input level of your external device as necessary. NOTE If you plan to add DAW software, such as Steinberg Nuendo, to an audio network that includes a CL console and I/O devices, you must use Dante Virtual Soundcard (DVS) driver software.
Input and output patching Word clock settings Setting up Dante Controller In a Dante network, the master device supplies accurate word clock to other devices on the network. If the master device is removed from the network or breaks down, another device will automatically take over as the clock master. To make this setting, in the Function Access Area, press the SETUP button, then WORD CLOCK/ SLOT button to access the WORD CLOCK/SLOT popup window.
Input channels Input channels STEREO channel These channels are used to process stereo signals. When the CL series console is in the default state, the input signal from the EFFECT RACK 1–8 is assigned. This chapter explains various operations for input channels. MIX 1 2 Signal flow for input channels ST IN 1L–8R INPUT PATCH MONO channel These channels are used to process monaural signals. When the CL series console is in the default state, the input signal from the Dante connector is assigned.
Input channels • LCR (Left/Center/Right) Sends the input channel signal to the STEREO bus/MONO bus as a three-channel signal that consists of the L/R channel plus the center channel. Specifying the channel name, icon and channel color • MIX ON/OFF (MIX send on/off) This is an on/off switch for signals sent from the input channel to MIX buses 1–24. On the CL series unit, you can specify the on-screen name and icon for each input channel.
Input channels 3. This popup window contains the following items: 2 3 Press the desired channel icon button. The lower part of the popup window will change as follows. 1 1 2 3 4 1 Channel color select buttons 1 PATCH button Select a channel color. Pressing the button will immediately apply the change. Indicates the currently-patched port. Press this button to enable the PATCH tab at the bottom of the screen. The PORT SELECT popup window will appear, enabling you to select the network and port.
Input channels 6. Making HA (Head Amp) settings If you want to enter a channel name directly (or edit a sample name that has been entered), press the channel name field in the upper part of the window. The keyboard window will appear in the lower part of the screen, allowing you to enter or edit the characters. This section explains how to make HA (Head Amp) related settings (phantom power on/off, gain, phase) for each input channel. Setting the analog gain 1.
Input channels GAIN/PATCH popup window (1ch) 1 • Gain compensation meter Indicates the level of the signal output to the audio network after gain compensation. 8 3 INPUT PORT button Indicates the port that is assigned to the channel. Press the button to display the PATCH popup window, in which you can select a port to patch. 4 Icon/Channel name button Indicates the channel number, icon, and name.
Input channels 6 GC (Gain Compensation) button GAIN/PATCH popup window (8ch) Switches the Gain Compensation function on or off for that channel. 7 Ø (Phase) button Switches the phase of the input signal. 1 8 D. GAIN (digital gain) knob Indicates the digital gain value. Press this knob so that you will be able to use the multifunction knob to adjust the gain. 2 3 9 Digital gain meter Indicates the level after digital gain.
Input channels ■ If you press the PATCH parameter select button: ■ If you press the ANALOG GAIN parameter select button: 2 3 4 1 1 1 PATCH button 1 GAIN knob Press this button to open the PORT SELECT popup window, in which you can select an input port to patch to the channel. Indicates the analog gain setting for each channel. Press this knob to control the gain value using the multifunction knob.
Input channels Setting the Gain Compensation function Adjusting the digital gain If you are using an I/O device (such as an Rio3224-D) on a Dante network, you can maintain the constant level of signal output to the audio network by using the Gain Compensation function.
Input channels Relationship between analog and digital gain while Gain Compensation is on Sending a signal from an input channel to the STEREO/MONO buses If Gain Compensation is on, adjusting the analog gain by a specific amount will cause the I/O device to output to the audio network a signal that is attenuated by the same amount. Therefore, the signals on the audio network will maintain a constant corrected level in the digital domain.
Input channels 1. 2. TO STEREO/MONO popup window (8ch) Make sure that an input source is connected to the input channel you are adjusting. Set the phantom power, gain, and phase of the head amp to obtain the optimum input signal. Here you can control the on/off and pan/balance settings of signals sent from input channels to the STEREO (L/R) bus and MONO (C) bus, in groups of eight channels.
Input channels TO STEREO/MONO popup window (CH1-48, CH49-72/ST IN(CL5), CH49-64/ST IN(CL3), ST IN(CL1)) Adjusts the status of a signal sent from the corresponding input channel to the STEREO/MONO bus. You can also adjust the pan or balance setting in groups of eight selected channels. 7 1 2 3 4 7 PAN/BALANCE MODE button Switches the knob function of the TO ST PAN/TO ST BALANCE knob on the STEREO channel.
Input channels Use the MODE button to select either ST/MONO mode or LCR mode for each channel. 6. In the MASTER section on the top panel, make sure that the [ON] key for the STEREO channel/MONO channel is turned on, and then raise the fader to an appropriate level. 7. In the INPUT section on the top panel, make sure that the [ON] key is turned on for the input channel you want to control, and then raise the fader to an appropriate position. 10.
Input channels Sending a signal from an input channel to a MIX/ MATRIX bus If the CSR knob is set to 100%, operating the INPUT TO ST PAN knob will change the level of signals sent to the STEREO (L/R) bus and MONO (C) bus, as shown in the following diagram. This section explains how to send a signal from an input channel to MIX buses 1–24 and MATRIX buses 1–8. The MIX buses are used mainly for the purpose of sending signals to foldback speakers on stage, or to effect processors.
Input channels 3. Press a knob in the SELECTED CHANNEL section to access the SELECTED CHANNEL VIEW screen. If necessary, you can specify two adjacent odd/even-numbered MIX/MATRIX buses as a stereo bus and link the main parameters. If the send-destination MIX/MATRIX bus is assigned as stereo, the left knob of the two adjacent TO MIX/MATRIX SEND LEVEL knobs will operate as the TO MIX/MATRIX PAN knob. (If BALANCE mode is selected in the TO STEREO/MONO popup window, it will operate as a BALANCE knob). 4.
Input channels 4. Using the Centralogic section You can use the multifunction knobs in the Centralogic section to adjust the send level of signals sent from eight consecutive input channels to a specific MIX/MATRIX bus. 1. 2. Make sure that an output port is assigned to each MIX/MATRIX bus to which you want to send signals, and that your monitor system, external effect, or other device is connected to the corresponding output port.
Input channels 6 Channel select button The knob for the mode selected here will appear. Selects the send-source channel that you wish to control. The current channel icon, number, and color appear on the button, and the channel name appears immediately below the button. 7 PRE/POST button Switches the send point of each send-source channel between PRE and POST. If the button is on, the send point is set to PRE. 8 SEND ON/OFF button Switches the send of each send-source channel on or off.
Input channels Using the faders (SENDS ON FADER mode) 3. Press the MIX1-16, MIX17-24/MATRIX switch button repeatedly to select MIX1-16 or MIX17-24/MATRIX. In this way, you can use the MIX/MATRIX bus select buttons to specify the destination MIX/ MATRIX buses. 4. Use the MIX/MATRIX bus selection buttons in the Function Access Area to select the send-destination MIX/MATRIX bus. You can use the faders on the top panel to adjust signals that are sent from all input channels to a specific MIX/MATRIX bus.
Input channels Correcting delay between channels (Input Delay) INPUT DELAY (8ch) 1 This section explains how to correct delay between input channels by using Input Delay function. This function is useful when you want to correct the phase variance, caused by microphone locations on the stage, to add depth to the sound by using phase variance, or to correct a delay (a gap) that may exist between video and audio that are sent from a site for broadcast on TV. 1.
Input channels Channel library operations INPUT DELAY (CH1-48, CH49-72/ST IN(CL5), CH49-64/ST IN(CL3), ST IN(CL1)) Channel libraries include “INPUT CHANNEL LIBRARY,” which enables you to store and recall various parameters (including the head amp settings) for input channels. To recall a library, press the corresponding LIBRARY button in the SELECTED CHANNEL VIEW screen. 1 2 3 LIBRARY button For details on using the library, refer to the “Using the library” section in the separate Owner’s Manual.
Output channels Output channels STEREO channel/MONO (C) channel Each of these channels processes the signal sent from the input channels to the STEREO bus or MONO (C) bus, and send it to the corresponding output port or MATRIX bus. If input channels are in LCR mode, the STEREO (L/R) channels and the MONO (C) channel can be used together as a set of three output channels. This chapter explains output channels (MIX channels, MATRIX channels, STEREO channels, MONO channels).
Output channels • MATRIX ON/OFF (MATRIX send on/off) This is an on/off switch for signals sent from the MIX channels, STEREO (L/R) channel, or MONO (C) channel to each MATRIX bus. Specifying the channel name, icon and channel color • MATRIX (MATRIX send level) Adjusts the send level of signals sent from the MIX channels, STEREO (L/R) channel, or MONO (C) channel to each MATRIX bus 1–8.
Output channels 2 Sending signals from MIX channels to the STEREO/ MONO bus 3 This section explains how to send a signal from a MIX channel to the STEREO bus or MONO bus. There are two ways to send signals to the STEREO bus or MONO bus: ST/MONO mode and LCR mode. You can select the mode individually for each channel. Features of each mode are the same as for input channels. 1 1.
Output channels TO STEREO/MONO popup window (8ch) If the ST/MONO/LCR mode select button is set to LCR mode, the following button and knob are displayed instead of the ST/MONO button (4). You can control the on/off and pan/balance settings of the signal sent from MIX channels to the STEREO (L/R) bus and MONO (C) bus, in groups of eight channels. 7 1 8 2 3 4 7 LCR button This button is an overall on/off button for signals sent from a channel to the STEREO bus and MONO bus.
Output channels TO STEREO/MONO popup window (CH1-48, CH49-72/ST IN(CL5), CH49-64/ST IN(CL3), ST IN(CL1), OUTPUT) 3. Access the eight-channel TO STEREO/MONO popup window. 4. Use the MODE button to select either ST/MONO mode or LCR mode for each channel. 5. In the MASTER section on the top panel, make sure that the [ON] key for the STEREO channel/MONO channel is turned on, and then raise the fader to an appropriate level. 6.
Output channels Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses 4. Press a knob in the SELECTED CHANNEL section to access the SELECTED CHANNEL VIEW screen. 5. Make sure that the TO MATRIX SEND ON/OFF button is turned on for the senddestination MATRIX bus. If this button is off, press the button on screen to turn it on. 6. In the SELECTED CHANNEL section, use the MIX/MATRIX SEND LEVEL knobs to adjust the send levels to the MATRIX buses.
Output channels 4. Using the Centralogic section This method lets you use the multifunction knobs (in the Centralogic section) to simultaneously adjust the send levels from the eight channels selected in the Centralogic section to the desired MATRIX bus. Use multifunction knobs 1–8 to adjust the send level of the signals sent from up to eight MIX channels or the STEREO/MONO channels to the selected MATRIX bus.
Output channels 5 Send destination select buttons The knob for the mode selected here will appear. Select MIX/MATRIX buses as the send destination. 6 Channel select button Selects the send-source channel that you wish to control. The current channel icon, number, and color appear on the button, and the channel name appears immediately below the button. 7 PRE/POST button Switches the send point of each send-source channel between PRE and POST. If the button is on, the send point is set to PRE.
Output channels 4. Using the faders (SENDS ON FADER mode) You can use the faders on the top panel to adjust signals that are sent from the MIX and STEREO/ MONO channels to a specific MATRIX bus. 1. Make sure that an output port is assigned to the MATRIX bus to which you want to send signals, and that your monitor system etc. is connected to the corresponding output port. 2. In the function access area, press the SENDS ON FADER button. The CL series unit will switch to SENDS ON FADER mode.
Output channels Correcting delay between channels (Output Delay) This section explains how to correct delay between output channels by using the Output Delay function. This Output Delay function is useful when you want to correct the timing of output signals sent to speakers that are located at a distance from each other. Output delay settings are made in the OUTPUT PORT popup window, which will appear when you press the OUTPUT PORT button from the SETUP screen.
EQ and Dynamics EQ and Dynamics HPF/EQ popup window (1ch) This lets you view and edit all EQ parameters of the currently-selected channel. This is convenient if you want to make detailed EQ settings for a specific channel. This chapter explains the EQ (equalizer) and dynamics that are provided on each channel of the CL series console. 8 D About EQ and dynamics Each input channel and output channel on a CL series console provides a four-band EQ and dynamics.
EQ and Dynamics 9 EQ FLAT button HPF/EQ popup window (8ch) Press this button to reset the GAIN parameters of all EQ band to 0 dB. This window displays the input channel or output channel EQ settings in groups of eight channels simultaneously. Use the knobs in the SELECTED CHANNEL section to edit the EQ settings. You can adjust the HPF settings of all eight channels displayed. 0 HIGH SHELVING ON/OFF button Turn on this button to select the shelving type filter for the HIGH band.
EQ and Dynamics 4. HPF/EQ popup window (CH1-48, CH49-72/ST IN(CL5), CH49-64/ST IN(CL3), ST IN(CL1), OUTPUT) This window displays the corresponding input channels (or output channels) simultaneously. This page is only for display, and does not allow the parameters to be edited. It is useful when you need to quickly check multiple EQ settings, or when you want to copy and paste EQ settings between distant channels.
EQ and Dynamics Using dynamics DYNAMICS 1/2 popup window (1ch) Input channels feature two dynamics processors; output channels feature one dynamics processor. This window displays only the currently-selected channel. All dynamics parameters can be viewed and edited. This is convenient if you want to make detailed dynamics settings for a specific channel. 1. 8 Use the Bank Select keys to access the OVERVIEW screen that includes the channel for which you want to control the dynamics.
EQ and Dynamics 7 Dynamics type buttons • GATE or DUCKING: Enable you to select the dynamics type. You can choose from the following dynamics types.
EQ and Dynamics DYNAMICS 1/2 popup window (8ch) If GATE is selected as the dynamics type, the indicator status means the following: This window displays the settings for eight channels, including the currently-selected channel. You can switch between eight-channel groups such as 1–8 and 9–16. Compared to the one-channel display, fewer parameters can be controlled.
EQ and Dynamics DYNAMICS 1/2 popup window (CH1-48, CH49-72/ST IN(CL5), CH49-64/ST IN(CL3), ST IN(CL1), OUTPUT) 3. Access the DYNAMICS 1/2 popup window (1ch), and press the DYNAMICS ON button to enable the dynamics processor. This window enables you to make settings of the global dynamics parameters for the corresponding channel. 4. To select a key-in signal, proceed as follows. 1 2 3 4 4-1.
EQ and Dynamics Using the EQ or Dynamics libraries You can use dedicated libraries to store and recall EQ and dynamics settings. EQ library LIBRARY button There is an “INPUT EQ LIBRARY” that lets you store and recall EQ settings for input channels, and an “OUTPUT EQ LIBRARY” that lets you store and recall EQ settings for output channels. To recall settings from a library, press the LIBRARY tool button in the HPF/EQ popup window.
Grouping and linking ■ Selecting channels to belong to a specific DCA group Grouping and linking 1. This chapter explains the DCA Group and Mute Group functions that enable you to control the level or muting of multiple channels together, the Channel Link function that links the parameters of multiple channels, and the operations that enable you to copy or move parameters between channels. About DCA groups and Mute groups 2.
Grouping and linking ■ Selecting the DCA groups to which a specific channel will belong 3 DCA group assign field This area displays the channels assigned to the currently-selected DCA group. While this window is displayed, press the [SEL] key for the channel that you want to assign to the DCA group. The on-screen fader for that channel will turn yellow and the channel will be assigned to the DCA group. Press the same [SEL] key once again if you want to remove the channel from the group. 1.
Grouping and linking Using mute groups Controlling DCA groups Use the faders in the Centralogic section to control DCA groups. 1. Assign input channels to DCA groups. 2. Using the faders in the Channel Strip section or Master section on the top panel, adjust the relative balance between the input channels that belong to the DCA group you want to use. 3. 4. This section explains how to assign channels to mute groups and use the USER DEFINED keys to control them.
Grouping and linking 6 MUTE GROUP MASTER button In this popup window you can select the channels that will be assigned to each mute group. The popup window includes the following items. Switches the corresponding mute group on or off. 7 DIMMER LEVEL knob 1 Sets the dimmer level for the corresponding mute group when the dimmer function is enabled. NOTE • In the case of the CL3/CL1, faders that do not exist on those models will not be shown.
Grouping and linking ■ Selecting the mute groups to which a specific channel will belong Using mute groups 1. Press the [SEL] key for the input channel/output channel that you want to assign. 2. Press a knob in the SELECTED CHANNEL section to access the SELECTED CHANNEL VIEW screen. In this screen you can view the mix parameters for the currently-selected channel. To control mute groups, you can use the MUTE GROUP MASTER buttons in the MUTE GROUP ASSIGN popup window.
Grouping and linking 3. Press the USER DEFINED KEYS tab to select the USER DEFINED KEYS page. The USER DEFINED KEYS page enables you to assign functions to USER DEFINED keys [1]– [16]. USER DEFINED key popup button 4. Press the popup button for the USER DEFINED key to which you want to assign the Mute On/Off function. The USER DEFINED KEY SETUP popup window will appear. 5.
Grouping and linking Channel Link function Using the Mute Safe function Specific channels that belong to a mute group can be temporarily excluded from mute group operations (Mute Safe). 1. In the Function Access Area, press the CH JOB button. 2. Press the MUTE GROUP button to access the DCA/MUTE GROUP ASSIGN MODE popup window. 3. Press the MUTE SAFE button. 4. Press a [SEL] key to select the channel(s) that you want to exclude from mute groups (multiple selections are allowed).
Grouping and linking 1 Channel display field Linking the desired input channels When you create a link group, the corresponding channels will be highlighted. If there are two or more link groups, each group is shown in a different color. This section explains how to link specific parameters of input channels. NOTE NOTE Channel link settings are saved as part of the scene. 1. 2. Left and right of the ST IN channel are always linked. In the Function Access Area, press the CH JOB button.
Grouping and linking 4. If you turned on the MIX ON, MIX SEND, MATRIX ON, or MATRIX SEND buttons in step 3, use the buttons in the SEND PARAMETER field to specify the bus(es) for which you want operations to be linked (multiple selections are allowed). The table below lists the buttons you can select in the SEND PARAMETER field. MIX 1–24 MIX buses 1–24 MATRIX 1–8 MATRIX buses 1–8 You can also perform the operations from step 5 on screen. 5. To link channels, press the channel display field.
Grouping and linking 1 SOURCE CH field Copying, moving, or initializing a channel This field displays the copy-source channel. While this window is displayed, press a [SEL] key on the top panel to select a channel. The field will indicate the selected channel. You can copy or move mix parameters between channels, or restore the parameters of a specific channel to their default settings.
Grouping and linking 3. Moving the parameters of a channel To select the copy-source channel, press the corresponding [SEL] key to make it light. The corresponding channel is highlighted in the SOURCE CH field of the window. When you choose the copy-source channel, the DESTINATION CHs field is automatically bolded, allowing you to select the copy-destination. If you want to re-select the copy-source channel, press the SOURCE CH field.
Grouping and linking 3 MOVE button This popup window lets you move channel settings. Executes a move operation. After selecting the move-source channel and move-destination channel, press this button to execute the move. 4 CLOSE button Press this button to close the popup window and return to the previous screen. 3. 1 2 3 To select the move-source channel, press the corresponding [SEL] key to make it light. The corresponding channel is highlighted in the SOURCE CH field of the window.
Grouping and linking Initializing the parameters of a channel 3. To select the channel(s) to be initialized, press the corresponding [SEL] key to make it light (multiple selections are allowed). The corresponding channel(s) are highlighted in the TARGET CHs field of the window. If you want to de-select all of the selected channels, press the TARGET CHs field. 4. To execute the initialization, press the DEFAULT button. The parameters of the selected channel(s) will be initialized.
Scene memory Scene memory Using scene memories This chapter explains how to perform scene memory operations. Storing and recalling scenes To store the current mix settings as a scene in memory and recall it later, you can use the keys in the SCENE MEMORY/MONITOR section on the top panel, or you can use the SCENE LIST window.
Scene memory NOTE 5. Press the SCENE MEMORY [STORE] key or the STORE button located in the lower part of the SCENE STORE popup window. The SCENE STORE popup window will close, and a dialog box will ask you to confirm the Store operation. 6. To execute the Store operation, press the OK button. The current mix settings will be stored to the scene number you selected in step 2. When the Store operation is complete, the scene number in the Function Access Area will stop blinking.
Scene memory ■ Using the SCENE LIST window 5 Write-protect 1. Use the controllers on the top panel or the buttons on the touch screen to set the mix parameters as desired. 2. Press the SCENE field in the Function Access Area. The SCENE LIST window will appear, in which you can perform various scene-related operations. The window includes the following items. Indicates the Write Protect on/off status. Press this button to write-protect the scene. A lock icon will appear.
Scene memory 3. 12. To store a scene, rotate one of the multifunction knobs to select the storedestination scene number. NOTE • You can select multiple scene numbers as the store-destination. To do so, press the MULTI SELECT button to turn it on, and then rotate a multifunction knob. Alternatively, rotate the multifunction knob while pressing and holding it down. • If you selected multiple scenes as the store-destination, the same contents will be stored in all selected scene numbers.
Scene memory 3. 5. Press the USER DEFINED KEYS tab to select the USER DEFINED KEYS page. The USER DEFINED KEYS page enables you to assign functions to USER DEFINED keys [1]– [16]. In the FUNCTION column, select “SCENE.” Proceed as follows, depending on the function you want to assign. • To assign INC RECALL or DEC RECALL Choose “INC RECALL” or “DEC RECALL” in the PARAMETER 1 column.
Scene memory 1 COMMENT sort button Editing scene memories Sorts scenes in alphabetical order of the comments in the COMMENT field. Each time you press this button, the list will alternate between ascending and descending order. This section explains how to sort the scenes stored in scene memory, edit their titles, and copy and paste them. 2 COMMENT field Press this field to open the SCENE COMMENT EDIT popup window, in which you can enter comments for the scene. Sorting scene memories 1.
Scene memory 4 TIME STAMP 4 CUT button Sorts the list in order of date of creation. Press this button to delete the selected scene and copy it to buffer memory. The numbers of the subsequent scenes will be decremented by one. NOTE By pressing the same location again, you can change the sorting order (ascending or descending). 5. 5 INSERT button Press this button to insert the scene copied to buffer memory into the selected scene number. The numbers of the subsequent scenes will be incremented by one.
Scene memory 4. Cutting a scene Rotate one of the multifunction knobs to select the paste-destination scene number, and then press the PASTE button. A dialog box will ask you to confirm the Paste operation. This section explains how to cut a scene. When you cut a scene, the numbers of the subsequent scenes will be decremented accordingly. You can paste or insert a cut scene at the desired location. 1. Press the SCENE field in the Function Access Area. The SCENE LIST window will appear. 2.
Scene memory Using the Global Paste function Inserting a scene You can insert a scene held in buffer memory at a desired scene number location. 1. Press the SCENE field in the Function Access Area. The SCENE LIST window will appear. 2. Perform the Copy operation (see page 83) or Cut operation so that the scene you want to insert is placed in buffer memory.
Scene memory 3. Use the tabs to select one of the following as the type of item you want to copy. INPUT OUTPUT RACK PATCH/NAME DCA 4. DYNA 1 INSERT INSERT PATCH FADER CH ON TO ST/BAL MONO MATRIX SEND MATRIX ON WITH SEND FROM SOURCE CHs Input channel and its parameters Output channel and its parameters GEQ/effect/Premium rack Input/output patch, channel name DCA group Select the copy-source channel or parameter. The view will vary depending on the tab you select.
Scene memory Using the Focus function 3 FOCUS PARAMETER indicators “Focus” is a function that lets you specify the scene parameters that will be recalled (loaded) when you recall a scene. You can specify these settings for each scene. This function is useful if you want to recall only the input channel settings of a specific scene. 4 CURRENT SETTING field These indicators show the focus recall settings that are specified for each scene.
Scene memory ■ Channel focus parameter display field Enables you to select parameters for each channel that will be affected by Recall operations. You can use the same procedure as that in the RECALL SAFE popup window. Using the Recall Safe function “Recall Safe” is a function that excludes only specific parameters/channels (DCA groups) from Recall operations. Unlike the Focus settings (see page 87), which you can apply to individual scenes, the Recall Safe settings are globally applied to all scenes.
Scene memory 2 CH RECALL SAFE field 9 SAFE PARAMETER SELECT field (excluding DCA groups) Indicates the channels currently specified for the Recall Safe function. Selects Recall Safe parameters for the selected channel. The button indication varies depending on the channel type, as follows: 3 SET BY SEL button • Input channel Enables you to use the [SEL] keys on the panel to select channels that will be affected by the Recall Safe function.
Scene memory 3. On-screen buttons and corresponding parameters apply to the following channels: Button name WITH MIX SEND Corresponding parameter Input channel Send level to the MIX bus MIX channel MATRIX channel STEREO/ MONO channel O WITH MATRIX SEND Send level to MATRIX bus O To select the channel or DCA group that will be affected by Recall Safe operations, press the corresponding [SEL] key. The corresponding channel or DCA group will be enclosed by a white frame in the CH RECALL SAFE field.
Scene memory 5. 6. Using the Fade function To enable Recall Safe for the selected channel, turn on the SAFE button in the SAFE PARAMETER SELECT field. (If you have selected a DCA group, turn on either the LEVEL/ON button or the ALL button.) Channels or DCA groups for which Recall Safe is enabled will be highlighted in the CH RECALL SAFE field. “Fade” is a function that smoothly changes the faders of specified channels and DCA groups to their new values over a specified duration when you recall a scene.
Scene memory 3 FADE TIME display 4. Press the [SEL] keys for the desired channels or DCA groups to select the channels or DCA groups to which the Fade effect will be applied (multiple selections are allowed). The [SEL] keys for the selected channels or DCA groups will light, and those channels or DCA groups will be highlighted green in the channel display field of the popup window. You can cancel the selection by pressing the lit [SEL] key once again to turn it off. 5.
Scene memory 1 GPI OUT CONTROL buttons Outputting a control signal to an external device in tandem with scene recall (GPI OUT) These specify the control signal will be output from each GPI OUT. Pressing a button repeatedly will switch between the following functions. • –––– (OFF) ................ Nothing will be output. • TRIGGER .................. A trigger will be output when the scene is recalled. • TALLY ........................ A tally will be output when the scene is recalled.
Scene memory Playing back an audio file that links to a scene recall The PLAYBACK LINK field is shown in the right half of the SCENE LIST window. You can also specify an audio file that you want to play back from a USB flash drive when a specific scene is recalled. This can be convenient if you want an effect sound or BGM to be played automatically in a specific scene. Follow the steps below to link a scene recall with audio file playback.
Scene memory 4. 7 OFFSET knob Press the song select popup button for a scene to which you want to link the audio file. The SONG SELECT popup window will appear. In this popup window, you can select an audio file you want to link with the scene, and set the offset time. 2 You can use the multifunction knob to set the time duration from scene recall until the start of audio file playback. 8 Scroll knob 3 Use the multifunction to scroll the list. 5.
Scene memory Using Preview mode Functions in Preview mode The current scene will be modified by the following software and external operations. • CL Editor • Stage Mix • MIDI Rx • GPI IN Preview mode lets you view or edit the settings of a scene stored in memory without affecting the signal processing of the current scene.
Monitor and Cue functions Monitor and Cue functions • MONITOR SELECT Selects the monitor source. This chapter explains the Monitor and Cue functions of CL series consoles. • METER Detects and indicates the level of the monitor signal or cue signal. About the Monitor and Cue functions • DIMMER Attenuates the monitor/cue signal by a fixed amount. • MONITOR LEVEL Adjusts the output level of the MONITOR OUT L/R/C channels.
Monitor and Cue functions 2 SOURCE SELECT field Using the Monitor function Selects the monitor source. If DEFINE has been selected in this field, access the MONITOR popup window to specify the source channel. This section explains how to select the desired monitor source, and monitor it from the PHONES Out jack or external monitor speakers. 1. 2. 3 DIMMER field Connect your monitor system to the OMNI OUT jacks or 2TR OUT DIGITAL jack on the rear panel.
Monitor and Cue functions 3. • DIMMER ON button Switches the Dimmer function on or off. The monitor signal will be attenuated if this button is on. Press the popup button or the meter field to open the MONITOR popup window. In the MONITOR popup window you can make detailed settings for monitoring. The popup window includes the following items. 3 5 4 TALKBACK DIMMER field 6 7 Enables you to make settings for the Dimmer function, which temporarily attenuates monitor signals when TALKBACK is on.
Monitor and Cue functions 5. 0 MONITOR DELAY field This field enables you to specify the monitor delay setting by which the monitor out signal is delayed. • AUTO BYPASS button Turn this on to automatically bypass monitor delay when the cue is on. To specify a port as the output destination for monitor signals L, C, and R, press one of the MONITOR OUT PATCH buttons (L/R/C) in the meter field to open the PORT SELECT popup window.
Monitor and Cue functions 8. 9. Using the Cue function To adjust the monitor level, use the MONITOR LEVEL knob located in the SCENE MEMORY/MONITOR section of the top panel. If PHONES LEVEL LINK is ON, use the MONITOR LEVEL knob and the monitor fader, as well as the PHONES LEVEL knob to adjust the monitor level when monitoring through headphones. About CUE groups Cue signals on the CL series console can be categorized into the following four groups.
Monitor and Cue functions Operating the Cue function This section explains how to use the [CUE] key for a channel or DCA group to monitor cue signals. NOTE Be aware that if you turn CUE INTERRUPTION off in the MONITOR popup window, the cue signal will not be sent to the connected monitor speakers. However, the front panel PHONES jack will always output the cue signal regardless of the Monitor on/off setting. See “Using the Monitor function” on page 98 for details about the Monitor function.
Monitor and Cue functions 4 CUE OUTPUT button 3 DCA CUE field Switches the cue out on or off. This section enables you to make settings related to DCA cue. • Cue point select button Sets the cue point for the DCA group to PRE PAN (immediately before PAN) or POST PAN (immediately after PAN). 5 CLEAR CUE button Cancels all cue selections simultaneously. If the CUE MODE setting is MIX CUE, all of the selected channels will be cleared. 2.
Monitor and Cue functions 3. 6. Use the CUE MODE button to select either the mode in which channels are mixed for auditioning, or the mode in which only the last-selected channel is auditioned. Select the MIX CUE button or LAST CUE button. NOTE The cue signal is sent to the monitor output and PHONES output jacks regardless of whether the CUE OUTPUT button is on or off. However, be aware that the cue signal will no longer be sent to monitor output if CUE INTERRUPTION is turned off.
Monitor and Cue functions 8. If you’re auditioning the CUE signal in the monitor, adjust the Cue signal level by using the MONITOR LEVEL knob located in the SCENE MEMORY/MONITOR section of the top panel. Also adjust the MONITOR FADER LEVEL in conjunction with this. If PHONES LEVEL LINK is ON, the cue signal level when monitoring through headphones can be adjusted in three ways: the CUE LEVEL knob, the MONITOR FADER, and the PHONES LEVEL knob.
Talkback and Oscillator Talkback and Oscillator Using Talkback The Talkback function sends the signal (that is input at the input jacks) to the desired bus. About the Talkback and Oscillator functions 1. Talkback is a function that sends the signal of a mic connected to the TALKBACK jack to the desired bus. This is used mainly to convey instructions from the operator or sound engineer to the performers and staff.
Talkback and Oscillator 3 INPUT TO TALKBACK field 2 INPUT TO TALKBACK field This field allows a mic connected to a conventional input port to be used as a talkback input. • INPUT TO TALKBACK patch button .......................... Press the button to open the PORT SELECT popup window, in which you can patch a desired input port to an input port to patch to talkback. The selected port name will appear on the button. • +48V indicator ..........................
Talkback and Oscillator 4. Using the Oscillator function If you want to use an input jack other than the TALKBACK jack as supplementary input for talkback, follow the steps below. You can send a sine wave or pink noise from the internal oscillator to the desired bus. 4-1. Press the INPUT TO TALKBACK patch button in the INPUT TO TALKBACK field to open the PORT SELECT popup window. 1. 4-2. Press the button for the input that you want to use for talkback to turn the button indicator on.
Talkback and Oscillator 4 OSCILLATOR ASSIGN field Mode = SINE WAVE An indicator lights to indicate the currently-selected oscillator output destination (input channels or buses). Use the tabs on the left to select channels or buses to display. NOTE In the case of the CL3/CL1, channels that do not exist on those models will not be shown. • LEVEL knob.............. Indicates the output level of the sine wave. • FREQ knob................ Indicates the frequency of the sine wave.
Talkback and Oscillator 3 ASSIGN section Enables you to select a channel to which the oscillator signal will be sent. Press one of the three tabs located at the bottom of the screen, then press the button(s) for the channel(s) in this section (multiple selections are allowed). The “ASSIGNED” indicator is lit green for a tab that contains a selection. You can press the CLEAR ALL button to defeat all selections. NOTE In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
Meters Meters INPUT METER screen This screen shows the meters and faders for all input channels. This chapter explains the METER screen that shows the input and output level meters for all channels, and operations related to the optional MBCL meter bridge. Operations in the METER screen By accessing the METER screen, you can view the input and output levels of all channels on the screen, and switch the level meter’s metering points (the points in the signal route at which the level is detected). 1.
Meters INPUT/OUTPUT tabs Centralogic fader display Use these tabs to switch between the INPUT METER screen and OUTPUT METER screen. This area displays the level of the faders currently set in the Centralogic section. Fader level and meter display METERING POINT field This area displays the meter, fader, and level value for each channel. 1 Select one of the following as the metering point at which the level will be detected. 2 3 4 ■ For INPUT METER • PRE HPF....................
Meters Using an MBCL meter bridge (optional) on the CL3 or CL1 console If the optional meter bridge (MBCL) is installed on the CL3 or CL1 console, you will always be able to view the output levels of MIX, MATRIX, STEREO, MONO, and CUE channels. The MBCL meters indicate the output levels in 12-segment steps (OVER, –3 dB, –6 dB, –9 dB, –12 dB, –15 dB, –18 dB, –24 dB, –30 dB, –40 dB, –50 dB, –60 dB). You can select the metering point (the point at which the level is detected) from the following choices.
Graphic EQ, effects, and Premium Rack Graphic EQ, effects, and Premium Rack MIX INSERT OUT 1-24 STEREO INSERT OUT L,R,MONO(C) This chapter explains how to use the built-in graphic EQ, effects, and Premium Rack. MATRIX INSERT OUT 1-8 About the virtual rack CL series consoles enable you to use the built-in graphic EQ (subsequently abbreviated as “GEQ”) and effects/processors to modify signals.
Graphic EQ, effects, and Premium Rack 2 Rack mount popup button Virtual rack operations Press this button to open the RACK MOUNTER popup window, in which you can select the type of the rack you want to mount. This section explains how to mount a GEQ or effect in the virtual rack, and patch the input and output of the rack as an example. 1. In the Function Access Area, press the RACK button to access the VIRTUAL RACK window. 3 SAFE toggle button Switches Recall Safe on or off for the rack.
Graphic EQ, effects, and Premium Rack 3. • If nothing is mounted: To mount a GEQ or effect in the rack, press the rack mount button for that rack. The RACK MOUNTER popup window will appear. 1 2 1 2 Press this area to open the RACK MOUNTER popup window, in which you can select the GEQ or effect that will be mounted in the rack. • If 31BandGEQ is mounted: 3 4 5 3 4 5 1 Rack number This area indicates the settings for each band, GEQ on/off status, and input/output level.
Graphic EQ, effects, and Premium Rack 4. 5. Use the MODULE SELECT buttons to select the item you want to mount, and press the OK button. 2 Channel select buttons To select the input source for a rack, press the INPUT PATCH button for that rack. The CH SELECT popup window will appear, allowing you to select the input source for the rack. Switch the list as necessary, and select the input source channel that you want to patch.
Graphic EQ, effects, and Premium Rack • • • • • • CH 65–72.................................... CH 65–72 *1, *2 INSERT IN 1–32 ....................... CH 1–32 *1 INSERT IN 33–64..................... CH 33–64 *1 INSERT IN 65–72..................... CH 65–72 *1 INSERT IN MIX/MATRIX..... MIX 1–24, MATRIX 1–8 INSERT IN ST/MONO............
Graphic EQ, effects, and Premium Rack 2. 3. In the GEQ field or the EFFECT field, press the rack in which you mounted the GEQ. The GEQ popup window will appear, allowing you to edit the GEQ parameters. NOTE The popup windows for the 31BandGEQ and the Flex15GEQ are nearly identical. However, the Flex15GEQ individually displays two GEQ units (A and B) mounted in a single rack. 2 3 4 5 If you are using a stereo source, link the two GEQ units.
Graphic EQ, effects, and Premium Rack Using the 31BandGEQ The buttons in the FADER ASSIGN field correspond to the following groups of bands. You will use the Centralogic section’s faders 1–8 and [ON] keys to control the 31BandGEQ. 1. 2. Refer to steps 1–6 in the “Virtual rack operations” section on page 115 to mount a 31BandGEQ in a rack and set its input source and output destination. The rack in which the 31BandGEQ is mounted will show the approximate settings and input and output levels.
Graphic EQ, effects, and Premium Rack Using the Flex15GEQ When you press one of these buttons, the faders for the bands selected on the touch screen will turn white, and the numbers of the corresponding faders in the Centralogic section will be displayed. Now you can use the faders in the Centralogic section to control the band. You will use the Centralogic section’s faders 1–8 and [ON] keys to control the Flex15GEQ. 1.
Graphic EQ, effects, and Premium Rack About the internal effects ■ STEREO type effects The internal effects of the CL series console can be mounted in EFFECT racks 1–8, and patched to an output channel’s output or input channel’s input, or inserted into a channel. For each effect mounted in a rack, you can choose one of 54 types of effect. With the default settings, the signals from MIX channels 17–24 are input to racks 1–8, and from the racks are then output to ST IN 1–8 (L/R).
Graphic EQ, effects, and Premium Rack 2. 3. 2 OUTPUT PATCH buttons Press the INPUT PATCH L button to open the CH SELECT popup window, and select a MIX channel as the input source for the rack. For details on the CH SELECT popup window, refer to step 5 of “Virtual rack operations” on page 115. The output of the MIX channel you are using as the effect send is now assigned to the L input of the effect.
Graphic EQ, effects, and Premium Rack 7. Use the MIX1-16, MIX17-24 and MATRIX keys of the SELECTED CHANNEL section (top panel) so that the SEND field shows the MIX bus that is patched as the effect send. You can also use the MIX1-16, MIX17-24 and MATRIX buttons in the SELECTED CHANNEL VIEW screen to switch the displayed bus. 2. Press the L side of the INPUT PATCH button to open the CH SELECT popup window, and select the insert-out of a channel as the input-source.
Graphic EQ, effects, and Premium Rack 1 INPUT PATCH buttons Editing the internal effect parameters Press these buttons to open the CH SELECT popup window. This section explains how to change the effect type and edit the parameters. 1. 2 OUTPUT PATCH buttons Follow steps 1–3 described in “Virtual rack operations” on page 115, to mount an effect in a rack. A rack in which an effect is mounted will show the following information. 1 Press these buttons to open the CH SELECT popup window.
Graphic EQ, effects, and Premium Rack 3. ■ TEMPO This field appears if a tempo-type or modulation-type effect is selected. To change the effect type, press the effect type field to open the EFFECT TYPE popup window. Press a new effect type to select it. 1 MIDI CLK button If you turn this button on, the BPM parameter of that effect will be set to match the tempo of the MIDI timing clock being input from the MIDI port. 1 ■ PLAY/REC This field appears if FREEZE is selected as the effect type.
Graphic EQ, effects, and Premium Rack ■ Type This field is displayed when Equalizer601 is selected as the effect type. 1 DRIVE button/CLEAN button Using the Tap Tempo function “Tap tempo” is a function that lets you specify the delay time of a delay effect or the modulation speed of a modulation effect by striking a key at the desired interval. To use the Tap function, you must first assign Tap Tempo to a USER DEFINED key, and then operate that USER DEFINED key.
Graphic EQ, effects, and Premium Rack This window includes several pages, which you can switch between using the tabs located at the bottom of the window. 3. 4. Press the popup button for the USER DEFINED key to which you want to assign the Tap Tempo function. The USER DEFINED KEY SETUP popup window will appear. 5. Select “TAP TEMPO” in the FUNCTION column, select “CURRENT PAGE” in the PARAMETER 1 column, and press the OK button.
Graphic EQ, effects, and Premium Rack 8. Using the Freeze effect Press the effect type field to open the EFFECT TYPE popup window, and select an effect type that includes the BPM parameter. The BPM parameter is included in delay-type and modulation-type effects, and can be used to specify the delay time or modulation speed. This section explains how to use the “FREEZE” effect type, which provides the functionality of a simple sampler.
Graphic EQ, effects, and Premium Rack 5. Using the Premium Rack To begin recording (sampling), press the REC button and then press the PLAY button. The signal being input to the effect will be recorded. The bar reflects the current recording progress. When a fixed time has elapsed, the buttons will automatically turn off. The procedure to set up the I/O patches for the rack are the same as those for the effect rack. (see page 122) For the premium rack, only racks 1–2 can be used via send/return.
Graphic EQ, effects, and Premium Rack 3. 4. To mount a Premium Rack in the rack, press the RACK MOUNT button for that rack. The PREMIUM RACK MOUNTER popup window will appear. Use the MODULE SELECT buttons to select the type you want to mount, and press the OK button. There are two ways to mount each processor: • DUAL ..........................The processor is used on two mono channels. • STEREO......................The processor is used on one stereo channel. 5.
Graphic EQ, effects, and Premium Rack 12. ■ Portico 5033 Portico 5033 is a processor that emulates a 5-band analog EQ developed by Rupert Neve Designs (RND). 5033EQ features a unique tone control response. It inherited the history of the “1073,” which was praised as one of the greatest devices developed by Mr. Rupert Neve. Yamaha’s VCM technology has modeled the EQ to the last detail, including the input/output transformer that was designed by Mr. Rupert Neve himself.
Graphic EQ, effects, and Premium Rack 6 LMF/MF/HMF IN button 3 FB button Turn LMF/MF/HMF EQ on or off respectively. Switches the gain reduction method between FF (Feed-Forward) circuit and FB (Feed-Back) circuit. The button will light when FB circuit is selected. The FF circuit is used in most contemporary compressors. This type is useful when you want to apply compression thoroughly while maintaining a consistent tonal color. The FB circuit is used in vintage compressors.
Graphic EQ, effects, and Premium Rack ■ U76 U76 is a processor that emulates a popular vintage compressor used in a wide range of situations. This processor does not provide the threshold parameter that is found on conventional compressors. Instead, the intensity of compression is determined by the balance between the input gain and the output gain. The “All mode” setting for the RATIO parameter allows you to create a heavily-compressed sound that is typical of this model.
Graphic EQ, effects, and Premium Rack ■ EQ–1A EQ-1A is a processor that emulates a famous passive-type vintage EQ. It features a unique style of operation, allowing you to individually boost and attenuate (cut) each of two frequency ranges (high and low). The frequency response is utterly unlike that of a conventional EQ, and is a uniquely distinctive characteristic of this model. The input/output circuits and vacuum tubes produce a tonal character that is highly musical and well-balanced.
Graphic EQ, effects, and Premium Rack 2 SIDECHAIN CUE button B THRESHOLD meter Press this button on to monitor the sidechain signal sent to the CUE bus. At this time, the graph indicates the filter response for the sidechain. Indicates the sidechain signal level in relation to the threshold level. C Graph area 3 SIDECHAIN LISTEN button Displays the equalizer response.
Graphic EQ, effects, and Premium Rack ■ Premium Rack library For the premium rack, there are six library items for each module type. You’ll use the library of each module type to store and recall Premium Rack settings. The libraries are numbered 000–100, and 000 is read-only data for initialization. All library items other than #000 can be freely read and written.
I/O device and external head amp 3. I/O device and external head amp This chapter explains how to use an I/O device or an external head amp that is connected to the CL series console. Before you proceed, use DANTE SETUP to specify the I/O devices that will be mounted. For details, refer to “Mounting an I/O device on the Dante audio network” on page 217. In the upper part of the I/O DEVICE screen, press the DANTE PATCH tab to access the DANTE PATCH field.
I/O device and external head amp 1 NOTE 2 • If you’ve connected a device other than an I/O device supported by the CL series, the upper line of the button will show the first four letters of the Device Label, a dash “-”, and the channel number (decimal). • If no Dante Audio Channel Label has been specified, the lower row will indicate nothing. • You can set the Dante Audio Channel Label using Audinate’s “Dante Controller” software. For the latest information, refer to the Yamaha pro audio website.
I/O device and external head amp 7. 2 Port select buttons To assign the output ports of the I/O device, select and press the I/O device in the DANTE PATCH field of the I/O device screen to access the OUTPUT PATCH popup window. The OUTPUT PATCH popup window will appear. Select the Dante port (DANTE 1–64) to which the signal you want to output is assigned. 3 CLOSE button Completes the settings and closes the popup window. 9.
I/O device and external head amp 2. 3 DANTE SETUP button Press this button to open the DANTE SETUP popup window, in which you can make settings for the audio network. ■ HA display This shows the HA settings of the I/O device. Press this area to open the I/O DEVICE HA popup window, in which you can make detailed head amp settings. To remotely control the head amp of an I/O device, press the I/O device in the HA display. The I/O DEVICE HA popup window will appear.
I/O device and external head amp 3. To remotely control the I/O device’s head amp from an input channel of the CL series console, use the bank select keys in the Centralogic section to access the OVERVIEW screen that includes the channel for which you want to control the head amp. 6. If you press a rack in which an output I/O device is mounted, the OUTPUT PATCH popup window will appear.
I/O device and external head amp 2. Remotely controlling an amp Press a displayed I/O device to open the OUTPUT PATCH popup window. Here’s how to remotely control an amp that’s connected to the Dante connector. 1 2 3 If you need to make output port settings, make these settings as described in step 7 and following of the I/O device patching procedure (see page 140). 1. In the upper part of the I/O DEVICE screen, press the AMP tab to access the AMP field. The AMP field includes the following items.
I/O device and external head amp Using an external head amp CL5 Audio signal If an I/O card (such as an MY16-ES64 card) supports the remote protocol of an external head amp in the CL’s slot, you will be able to remotely control from the CL console some parameters of the external head amp (Yamaha SB168-ES or AD8HR), such as phantom power (+48V) on/off status, gain, and HPF. For details on the I/O card settings, refer to the owner’s manual for the I/O card.
I/O device and external head amp ■ Ring connection Connecting the CL series console to an SB168-ES CL5 To remotely control the SB168-ES from the CL series console, install an MY16-ES64 EtherSound card in Slot 1 on the CL, then use an Ethernet cable to connect the CL to the SB168-ES. This connection enables you to remotely control the SB168-ES from the CL series console.
I/O device and external head amp Remotely controlling an external head amp The EXTERNAL HA field includes the following items. 5 You can remotely control from the CL series console an external head amp (“external HA”) connected via MY16-ES64 or NAI48-ES. 1. Connect the CL series console to an external HA. For details, refer to the “Using an external head amp” on page 144 section and the owner’s manual of your external HA. 2.
I/O device and external head amp 6 COMM PORT switch buttons Specifies whether the external HA connected to the slot will be controlled remotely. Select “SLOT1” if you want to remotely control the external HA. 4. 5. 1 2 Press the “SLOT1” COMM PORT switch button. The external HA units that can be controlled will appear in the virtual rack. 3 To specify the input ports for an external HA, press the EXTERNAL HA PORT SELECT popup button for that rack. The EXTERNAL HA PORT SELECT popup window will appear.
I/O device and external head amp 8. To remotely control the external HA from an input channel of the CL series console, use the Bank Select keys to access the OVERVIEW screen that includes the channel on which you want to control the HA. GAIN/PATCH field 9. Press the GAIN/PATCH field of the channel on which you want to control the external HA. The GAIN/PATCH popup window will appear. 10. Press the PATCH button, and select the input port assigned to the external HA.
MIDI MIDI Basic MIDI settings You can select the type of MIDI messages the CL series console will transmit and receive, the MIDI port that will be used, and the MIDI channel. This chapter explains how to transmit MIDI messages from an external device to the CL series console to control the CL console’s parameters, and how to send out MIDI messages from the CL console as you operate the unit. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2.
MIDI 3. Press the MIDI SETUP tab to access the MIDI SETUP page. In the MIDI SETUP page you can select the type of MIDI messages that will be transmitted and received, and choose the port that will be used. This page includes the following items. • OMNI ......................... If this button is on, Program Changes on all MIDI channels will be transmitted and received in Single mode. Multi mode transmission/ reception and Single mode transmission are disabled. • BANK .........................
MIDI 4. 6. To specify the port that will be used to transmit or receive each type of MIDI message, press the transmit (Tx) or receive (Rx) port select popup button. The MIDI SETUP popup window for selecting the port will appear. Operations in this window are the same for both transmission (Tx) and reception (Rx). This window includes the following items. 1 1 2 1 CH field 1 TERMINAL field Enables you to select CH1–CH16 as the channel that will transmit or receive MIDI messages.
MIDI Using Program Changes to recall scenes and library items This page includes the following items. The CL series console lets you assign a specific event (scene recall or effect library recall) to each Program Change number, so that when this event is executed on the CL console, a Program Change message of the corresponding number will be transmitted to an external device. Conversely, the corresponding event can be executed when a Program Change message is received from an external device. 1.
MIDI • When the BANK button is on: The CH indication in the list will change to BANK (bank number), and Bank Select (Control Change #0, #32) and Program Change messages can be transmitted and received. This can be convenient if you want to control more than 128 events on a single MIDI channel. When Bank Select and then Program Change messages (in that order) are received on the Rx channel, the event assigned to that bank number and program number in the list will be executed.
MIDI 8. 9. To change the event assignment for each program number, press the desired event in the list. The MIDI PROGRAM CHANGE popup window will appear. In this window, you can specify the event assigned to each program number. This popup window includes the following items. 1 2 3 Use the TYPE field to select the type of event to assign. If the type is other than SCENE, use the DESTINATION field to select the rack number into which you want to recall the item.
MIDI Using Control Changes to control parameters You can use MIDI Control Change messages to control specified events (fader/knob operations, [ON] key on/off operations etc.) on the CL series console. This capability can be used to record fader and key operations on a MIDI sequencer or other external device, and play back this data later. You can use Control Changes to control events in either of the following two ways.
MIDI 6. 1 MODE field Use the buttons in the CONTROL CHANGE MODE field to select the Control Change transmission/reception mode. You can choose one of the following two modes for Control Change transmission/reception. Enables you to select the type of event. 2 PARAMETER 1/2 field • NRPN mode (when the NRPN button is on): Various mix parameters on the CL series console will be transmitted and received on a single MIDI channel as NRPN messages.
MIDI Using Parameter Changes to control parameters On the CL series console, you can use a type of system exclusive messages called “Parameter Changes” to control specific events (fader/knob operations, [ON] key on/off operations, system and user settings, etc.) as an alternative to using Control Changes or NRPN messages. For details on the Parameter Changes that can be transmitted and received, refer to “MIDI data format” in the Appendices. 1. Connect the CL series console to an external device. 2.
User settings (Security) User settings (Security) Privileges for each user are as follows. This chapter explains the following settings and operations: the User Level settings that restrict access to the parameters by certain users, the Console Lock function that temporarily denies access to the console, the Preference settings that customize the operating environment, and Save/Load operations using a USB flash drive.
User settings (Security) 2. 3. Creating a user authentication key Press the PASSWORD CHANGE button. A keyboard window will appear, allowing you to enter a password. You can create a user authentication key and save it on a USB flash drive or in the console’s internal memory. A user authentication key can be created only by an Administrator or Power User.
User settings (Security) The CREATE USER KEY popup window will appear. 2 3 4. When you have specified the user name, comment, password, power user privileges on/off, and user rights, press the CREATE button. The CREATE KEY popup window will appear. 5. If you want to create a user authentication key in the console’s internal memory, press a button in the CREATE TO INTERNAL STORAGE field. You can store ten keys in the console’s internal memory. 6.
User settings (Security) Logging-in 2. Press the log-in button to open the LOGIN popup window. 3. Press the ADMINISTRATOR button, and then press the LOGIN button. If no Administrator password has been set, you will simply be logged-in. If a password has been set, a keyboard window will appear, allowing you to enter the password. 4. Enter the password and press the OK button. If the password was incorrect, a message of “Wrong Password!” will appear near the bottom of the screen.
User settings (Security) ■ Logging-in as Guest 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the log-in button to open the LOGIN window. ■ Logging-in as a User To log-in as a User, you will use a user authentication key saved in the console or on a USB flash drive. If using a USB flash drive, you may also log-in using a user authentication key created on a different CL series console. With a user authentication key stored in the console 3. 1.
User settings (Security) If no password has been set, you will simply be logged-in. If a password has been set, a keyboard window will appear, allowing you to enter the password. 4. Enter the password and press the OK button. If the password was incorrect, a message of “Wrong Password!” will appear near the bottom of the screen. 3. Press the log-in button to open the LOGIN window. 4. In the LOAD FROM USB STORAGE field, click the (LOAD .CLU FILE) popup button.
User settings (Security) 5. 6. Changing the password Rotate the multifunction knob to select the user authentication key for the user as whom you want to log in. For details about loading files from the USB flash drive, refer to “Loading a file from the USB flash drive” on page 178. Follow the steps below to change the password of the logged-in user. A change in the Administrator password is updated immediately.
User settings (Security) Editing a user authentication key The SAVE KEY popup window will appear. If you are logged-in as a user, you can edit your preference settings, USER DEFINED keys, USER DEFINED knobs, assignable encoders, custom fader banks, master fader, comments, and password, and save (overwrite) them onto your user authentication key. If you are logged-in as a Power User, you can also change the user level. 1.
User settings (Security) 2. Changing the user level Press the USER SETUP button to access the USER SETUP popup window. 8 You can view or change the user level. • Administrator ...........The Administrator does not have a user level setting, but can change the user level setting of the Guest account. • Guest ...........................The Guest can view the user level setting of the Guest account, but cannot change it. • Normal user ...............
User settings (Security) 5 FILE LOAD • HA................................................ Restricts operation of the HA (Head Amp) patched to that channel. • PROCESSING ........................... Restricts operation of all signal processing parameters for that channel (excluding the fader, channel on/off, and send level). • FADER/ON ................................ Restricts operation of that channel’s fader, channel on/off, and send level. • WITH SEND .............................
User settings (Security) 2 PATCH field Preferences Enables you to turn on or off options related to patch operations. Follow the steps below to make various settings for the CL console operating environment, such as how popup windows appear, and whether [SEL] key operations will be linked. These settings are changed for the user who is logged-in, but if you are logged-in as the Administrator, you will also be able to change the Guest settings.
User settings (Security) USER DEFINED keys • POPUP APPEARS WHEN KNOB(S) PRESSED Specifies whether pressing a knob in the SELECTED CHANNEL section while the SELECTED CHANNEL VIEW screen is displayed will cause a popup window (1ch) to appear. If the ON button is lit, a popup window (1ch) will open (or close) whenever you press a knob.
User settings (Security) 4. Using the Alternate function Press the button corresponding to the USER DEFINED key to which you want to assign a function. The USER DEFINED KEY SETUP window will appear. In this window, you can select a function to assign to the USER DEFINED key, and select the parameters.
User settings (Security) USER DEFINED knobs This section explains how to assign the desired functions to the USER DEFINED knobs in the USER DEFINED KNOBS section on the top panel, and press these knobs to execute the defined function. This assignment procedure will define the USER DEFINED knobs for the user who is currently loggedin, but if you are logged-in as the Administrator, you can also make USER DEFINED knob settings for the Guest account. 1.
User settings (Security) Assignable encoders 4. Press the button in the ASSIGNABLE ENCODER field. The ASSIGNABLE ENCODER SETUP popup window will appear. 5. Use the / buttons in the lower part of the field or the multifunction knobs on the top panel to select the function you want to assign. For details on the assignable functions and their parameters, refer to “Functions that can be assigned to the assignable encoders” on page 263.
User settings (Security) 2 MASTER FADER field Custom fader bank • MASTER button Press this button to set channels that will be controlled by the faders in the Master fader section. Groups that organize channels routed to the top-panel faders are called “fader banks.” There are input and output channel banks, as well as custom fader banks. Custom fader banks enable you to select various combinations of channels, regardless of channel types. This section explains how to set up a custom fader bank. 1.
User settings (Security) 8. To assign channels to other faders, repeat steps 4 through 7. Master fader 9. If necessary, select channels by pressing the channel select popup buttons. You can set channels that will be controlled by the two faders in the Master fader section. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the USER SETUP button to access the USER SETUP popup window. 3.
User settings (Security) Console Lock You can temporarily prohibit console operations in order to prevent unwanted operation. This setting completely disables operations of the panel and touch screen, so that controllers cannot be operated by an accidental touch or by an unauthorized third party while the operator is taking a break. If a password is set for the currently logged-in user, that password will be used for the Console Lock function.
User settings (Security) Unlocking the console If you are logged-in as a user for whom a password is set, a keyboard window will appear, allowing you to enter the password. 1. Press the CONSOLE LOCK screen. If you are logged-in as a user for whom no password is set, the console will be unlocked. If you are logged-in as a user for whom a password is set, a keyboard window will appear, allowing you to enter the password. 2.
User settings (Security) Saving and loading setup data to and from a USB flash drive 2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window. 3. If necessary, press the directory icon and change the directory. To move to the next higher level, press the arrow button in the PATH field. 4. Press the SAVE button. A keyboard window will appear, allowing you to enter a file name and comment. 5. Enter a file name or comment, and press the SAVE button.
User settings (Security) 6. Loading a file from the USB flash drive Follow the steps below to load CL settings file (extension .CLF) from the USB flash drive into the CL series console. You can use the same procedure to load the following files as well as setting files. Extension .CLF Type ALL Contents of file Press the OK button to begin loading the file. When the file has finished loading, the PROCESSING popup window that shows the progress of the loading operation will close.
User settings (Security) 4 MAKE DIR button NOTE The DANTE SETUP settings SECONDARY PORT and CONSOLE ID will not be changed even if the WITH DANTE SETUP AND I/O DEVICE button is on. Creates a new directory. 5 PATH 3. Indicates the name of the current directory. Press the arrow button to move to the next higher level. If the current directory is the top level, the arrow button is dimmed. 6 VOLUME NAME/FREE SIZE Perform the desired editing operation.
User settings (Security) ■ Copying and pasting a file Follow the steps below to copy a desired file into buffer memory, and then paste it with a different file name. 1. Formatting a USB flash drive Follow the steps below to format a USB flash drive. A USB flash drive with a capacity of 4GB or larger will be formatted in FAT32, and a USB flash drive with a capacity of 2GB or smaller will be formatted in FAT16. Turn the multifunction knob to select the copy-source file, and press the COPY button.
Recorder Recorder Assigning channels to the input and output of the recorder This chapter explains the functionality and operation of the recorder. Follow the steps below to patch the desired channels to the input and output of the USB memory recorder. You can patch any desired output channel or the direct output of an INPUT channel to the recorder input, and you can patch the recorder output to any desired input channel.
Recorder 4 RECORDER INPUT meters • • • • Indicate the level of the signals input to the recorder. 5 PLAYBACK OUT popup buttons (L/R) Press these buttons to open the CH SELECT popup window, in which you can select the signals patched to the recorder’s L/R output channels for playback. NOTE In the case of the CL3/CL1, channels that do not exist on those models will not be shown. 6 PLAYBACK OUT GAIN knob Sets the level of the recorder playback output signal. 4.
Recorder 2 Channel select buttons Recording audio to a USB flash drive Select the channels that will be patched to the USB memory recorder’s playback outputs, from the following choices. • CH1–72....................................... INPUT channels 1–72 • STIN 1L/1R–STIN 8L/8R ........ ST IN channels 1–8 L/R You can record the signal of the desired output channels as an audio file (MP3) onto the USB flash drive inserted in the USB connector located to the right of the display. 1.
Recorder ■ PLAY MODE field This field enables you to specify how the recorder will behave when playback of the current song is complete. 3 Remaining time display Indicates the remaining playback time of the current song during playback. 4 Current song format B SINGLE button Indicates the file format and bit rate of the current song (the file being played back). If this button is on, only the current song will play.
Recorder 5. Playing back audio files from a USB flash drive To monitor the signal being recorded, raise the fader for the channel(s) that are patched to the input of the recorder. The level of the input signal to the recorder is shown by the RECORDER INPUT field’s level meter in the RECORDER screen. If necessary, use the GAIN knob in the RECORDER INPUT field to adjust the input level to the recorder. You can play back audio files that have been saved on your USB flash drive.
Recorder 2 Status indicator • The folders that can be selected are restricted to the SONGS folder inside the YPE folder, and folders located below the SONGS folder. • The CL series console can recognize a file name that is a maximum of 64 single-byte characters. If the file name is longer than this, the desired file may not play correctly. • A maximum of 300 songs can be managed in a single directory. A maximum of 64 subdirectories can be managed.
Recorder 6 SONG TITLE/FILE NAME button Editing the title list Enables you to select either song title or file name to be displayed in the SONG TITLE/FILE NAME field. You can change the order of the audio files shown in the title list, and edit the titles or artist names. 1. Connect a USB flash drive containing audio files to the USB connector. 3. 2. In the Function Access Area, press the RECORDER button to access the RECORDER screen (USB tab). In the screen, you can use the folder icon in the NO.
Recorder Using the CL console with Nuendo Live The following example shows Dante Controller settings for patching I/O device channels 1–16 to DVS. The CL series consoles can operate in an integrated manner with Steinberg’s Nuendo Live DAW software.
Recorder 6 Location information display Recording into a project 1. In the Function Access Area, press the RECORDER button to access the RECORDER screen. 2. Press the Nuendo Live tab in the upper right of the screen. The Nuendo Live screen will appear. This displays information for the current location of the Nuendo Live project. You can press the button at the right to switch the time display format. 7 GO TO PROJECT START button Returns the location to the start of the project.
Recorder 3. Press the EASY RECORDING button to start recording. 4. When you have finished recording, press the record lock button and then the STOP button. ■ When setup method selection button = DVS To choose from a list of the I/O devices on the Dante audio network, press the DVS button to display the DEVICE LIST field. Specifying DVS or DANTE-ACCEL 1. In the Nuendo Live screen, press the NUENDO Live SETUP button. The NUENDO LIVE SETUP popup window will appear.
Recorder ■ When setup method selection button = SPECIFIED IP ADDRESS If you’re using DANTE-ACCEL, use the SPECIFIED IP ADDRESS field to specify the IP address of the PC. Since the IP address of DANTE-ACCEL will differ from the IP address used by CL Extension, you must specify the IP address manually. NOTE Depending on the firmware version, DANTE-ACCEL might not support redundant networking.
Recorder Playing a multi-track project 1. In the Nuendo Live screen, press the DANTE INPUT PATCH button. 2. Assign the signals from Nuendo Live to the desired DANTE1–DANTE64 ports. For example, press the PORT SELECT button for DANTE1. The PORT SELECT popup window will appear. 3. In the list at the left, select the DVS you’re using with Nuendo Live, and select the port that you want to assign to DANTE1. 4.
Help function Help function 4. To select the Help file (file extension: .xml) that you want to load, press one of the Help files in the file list, or turn the multifunction knob on the panel. You can view Help files provided by Yamaha, or display any user-created text file. 5. Press the LOAD button. A confirmation dialog box will appear. We accept no responsibility for any damage that may occur as a result of using Help files created by a third party other than Yamaha. 6.
Help function Viewing Help Using USER DEFINED keys to recall Help directly 1. Before you proceed, load the Help file or text file from your USB flash drive. 1. Before you proceed, load the Help file from your USB flash drive. 2. In the Function Access Area, press the popup window. 2. In the Function Access Area, press the SETUP button to access the SETUP screen. 3. By turning multifunction knobs 1–2 you can scroll the index area at the left.
Help function 4. ■ Recalling the HELP popup window using only a USER DEFINED key Press the USER DEFINED KEYS tab to select the USER DEFINED KEYS page. 9. Press the USER DEFINED key to which the Help function is assigned. The HELP popup window will appear. 10. To close the window, once again press the USER DEFINED key to which the Help function is assigned. ■ Directly recalling the Help for a specific panel controller 5.
Other functions 3 COMMENT EDIT popup button Other functions Press this button to open the USER COMMENT EDIT popup window, in which you can enter comments. This chapter explains various functions of CL series consoles that are not covered in other chapters. 4 PASSWORD CHANGE popup button Press this button to open the PASSWORD CHANGE popup window, in which you can change the password.
Other functions ■ CONTRAST/BRIGHTNESS field This field enables you to set the LCD brightness and contrast. B MIDI/GPI popup button Press this button to open the MIDI/GPI popup window, in which you can make MIDI and GPIrelated settings. H BANK A/BANK B buttons C DANTE SETUP button Select a bank to which you want to save the brightness and contrast settings. You can save two different settings in bank A and B, and switch between them if desired. Press this button to open the DANTE SETUP popup window.
Other functions 2. Word clock and slot settings “Word clock” refers to the clock that provides the basis of timing for digital audio signal processing. To send and receive digital audio signals between devices, those devices must be synchronized to the same word clock. If digital audio signals are transferred in an unsynchronized state, the data may not be transmitted or received correctly, and noise may be present in the signal, even if the sampling rates are the same.
Other functions ■ SLOT SETUP field This field enables you to make various settings related to the MY slots on the rear panel of the console. • DANTE 48 k • DANTE 44.1 k The word clock supplied from the Dante jack on the rear panel of the console will be used as the clock source. 3 2 4 1 • SLOT 1–3 The word clock supplied via a digital I/O card installed in a console slot will be used as the clock source. Word clock can be selected in pairs for each slot.
Other functions Using cascade connections Operations on a cascade slave CL unit Using multiple CL series consoles, or a CL console and an external mixing console (such as a Yamaha PM5D) in a cascade connection enable buses to be shared among the devices. This can be convenient if you want to use an external mixer to increase the number of inputs. This section explains cascade connections and operation, using an example in which two CL units are connected in a cascade configuration. 1.
Other functions 4. 7. Press the port select popup button for the bus for which you want to assign the port. The PORT SELECT popup window will appear. If you want to use the Cascade Link function to link parameters and events between two CL consoles, proceed as follows. 7–1. Use the CASCADE COMM PORT field to select the port that will transmit and receive control signals for cascade link. You can choose from the following items. • NONE .......... No link operation • MIDI............
Other functions Operations on the cascade master CL unit Basic settings for MIX buses and MATRIX buses 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. In the SYSTEM SETUP field located in the center of the SETUP screen, press the CASCADE button to open the CASCADE popup window.
Other functions 3 Send point select buttons (MATRIX bus only) Switching the entire phantom power supply on/ off Select the pre-fader send point from the input channel. These buttons correspond to the following parameters. Button Pre-fader send point PRE EQ Immediately before the EQ PRE FADER Immediately before the fader 1. In the function access area, press the SETUP button to access the SETUP screen. 2. In the center of the SETUP screen, press the +48V MASTER field’s ON button or OFF button.
Other functions Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps Setting the date and time of the internal clock This section explains how to set the date and time of the CL console’s internal clock, and how to select the date and time display format. The date and time you specify here will affect the time stamp used when saving a scene.
Other functions 3. Setting the network address This section explains how to set the network address that will be required when you use the NETWORK connector on the CL series console to connect it to a computer. NOTE Only the Administrator can change network settings. 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. In the center of the SETUP screen, press the NETWORK button to access the NETWORK popup window.
Other functions Initializing the unit to factory default settings If an error occurs in the CL console internal memory, or if you forget the password and cannot operate the unit, you can use the following procedure to initialize the internal memory. 3. A dialog box will ask you to confirm the initialization. Press the INITIALIZE button. A dialog box will ask you to reconfirm the operation. 4. Press the OK button in the confirmation dialog box. The Initialization operation starts.
Other functions 2. Adjusting the detection point of the touch screen (Calibration function) Press the TOUCH SCREEN CALIBRATION button. The TOUCH SCREEN CALIBRATION MODE screen will appear, allowing you to calibrate the touch screen. Follow the steps below to correctly align the positions of the LCD display and the touch screen. 1. While holding down the SCENE MEMORY [STORE] key on the panel, turn on the power to the CL unit. After the opening screen, the following startup menu screen will appear.
Other functions Adjusting the faders (Calibration function) 2. Press the FADER CALIBRATION button. The FADER CALIBRATION MODE screen will appear, enabling you to adjust the faders. The specified faders in the channel strip section, Centralogic section, and Master section will be semi-automatically calibrated. This window will also appear if a problem is detected in the fader settings while the CL is starting up. 3. Press a [SEL] key to specify the faders that you want to calibrate.
Other functions 8. Repeat steps 6–7 to adjust the faders for positions 1 through 4. After the positions are corrected, automatic motorized calibration will start. Fine-tuning the input and output gain (Calibration function) 9. When calibration is complete and if the RESTART button has not appeared, press the APPLY button. The calibration settings will be saved in internal memory. If the RESTART button appears, calibration has failed. Press the RESTART button to execute calibration once again.
Other functions • INPUT PORT TRIM (Fine adjustment of the analog input gain) Access the INPUT PORT TRIM window, and make fine adjustments to the gain of the specified analog input port in 0.1 dB steps. • SLOT OUTPUT TRIM (Fine adjustment of the slot output port gain) Access the SLOT OUTPUT TRIM window, and make fine adjustments to the gain of the output ports of the specified slot in 0.01 dB steps.
Other functions 2. Adjusting the channel color (Calibration function) If necessary, you can adjust the channel color. 1. Press the CHANNEL COLOR CALIBRATION button. The CHANNEL COLOR CALIBRATION MODE screen will appear, allowing you to adjust the channel color. While holding down the SCENE MEMORY [STORE] key on the panel, turn on the power to the CL unit. After the welcome screen, the following startup menu screen will appear.
Other functions 6. Adjusting the brightness of the channel name display When you have finished adjusting the color, press the APPLY button located on the right of the window to confirm the change. If necessary, you can adjust the brightness of the channel name display. NOTE 1. While holding down the SCENE MEMORY [STORE] key of the panel, turn on the power. After the welcome screen, the following startup menu screen will appear. 2. Press the CHANNEL COLOR CALIBRATION button.
Other functions Adjusting the contrast of the channel name display Dante audio network settings You will use the CL series console to make Dante audio network settings for the console itself and the I/O devices connected to the Dante connector of the CL series console. This section explains how to make Dante audio network settings. If necessary, you can adjust the contrast of the channel name display. 1. While holding down the SCENE MEMORY [STORE] key of the panel, turn on the power.
Other functions 3. 5 BIT select buttons In the upper part of the DANTE SETUP popup screen, press the SETUP tab to access the SETUP field. Enable you to set the audio bit depth to 24-bit or 32-bit. NOTE 1 24bit: Use this when transmitting and receiving data to or from an Rio unit. When using a CL series system, you will normally use this setting.
Other functions Switching the CONSOLE ID and SECONDARY PORT 1. In the SETUP field, select the CONSOLE ID and the SECONDARY PORT. Setting the Dante audio network latency An appropriate latency setting for signals sent and received via a Dante audio network varies depending on the network connection method and size. This section explains how to set an appropriate latency setting depending on the connection method of Dante-enabled devices that are connected to the CL series console.
Other functions Daisy chain connections FOH and monitor consoles are sharing 64-in/48-out. Redundant connections FOH and monitor consoles are sharing 64-in/48-out. 4 3 2 3 2 4 3 1 1 2 1 4 hops = 0.5 ms 4 hops = 0.5 ms 3 hops = 0.25 ms Redundant connections Simple 64-in/48-out Daisy chain connections 256-ch HA remote (maximum size) 9 3 8 3 4 7 6 4 5 4 1 2 2 3 2 4 hops = 0.5 ms 1 9 hops = 1.0 ms 216 1 4 hops = 0.
Other functions Mounting an I/O device on the Dante audio network Redundant connections Two consoles are sharing 256-ch HA remote (maximum size) Here’s how to select which of the multiple I/O devices on the Dante audio network will be mounted so that they can be used. Up to 24 units can be mounted for one CL series console. 1. In the lower part of the DANTE SETUP popup screen, press the DEVICE MOUNT tab to access the DEVICE MOUNT field. 1 4 2 5 3 1 2 5 hops = 0.
Other functions 2. ■ When the setup method select button is DEVICE LIST To mount by choosing from a list of the I/O devices on the Dante audio network, press the DEVICE LIST button to display the DEVICE LIST field. Press an I/O device select button to access the DEVICE SELECT popup window. 1 3 1 2 1 Setup method selection buttons Choose one of the following methods for mounting the I/O device. • NO ASSIGN............................... Not mounted • DEVICE LIST............................
Other functions ■ When the setup method select button is SUPPORTED DEVICE If you want to select and mount an I/O device that is supported by the CL series, press the SUPPORTED DEVICE button to see the SUPPORTED DEVICE field. These settings can be made even when not connected to a Dante audio network. NOTE • If there is one I/O device, set the I/O device’s UNIT ID to “1”. • If multiple devices are connected, assign the ID numbers so that there is no conflict between devices.
Other functions ■ When setup method selection button = DVS REMOTE HA settings ■ When setup method selection button = MANUAL If you want to enter the device label of an I/O device and mount it, press the DVS or MANUAL button to access the DVS/MANUAL field. Here’s how to select which of the multiple HA devices on the Dante audio network will be mounted so that they can be used. Up to 8 units can be mounted for one CL series console. 1.
Other functions 2. Using GPI (General Purpose Interface) Press a HA device select button to access the REMOTE HA SELECT popup window. The rear panel GPI (General Purpose Interface) connector can be used as an input/output connector. This connector provides five GPI IN ports and five GPI OUT ports. For example you can use an external switch to control internal parameters of the CL series console or to switch scenes.
Other functions 3. 4. Press the MIDI/GPI button. The MIDI SETUP screen will appear. Press the GPI tab. The GPI page will appear. 3 1 2 1 GPI IN status indicator This indicates the status of the voltage being input to the GPI IN port. 2 POLARITY MODE select button This button selects the polarity of the GPI IN port. ............ (Low active) When operating an on/off-type parameter, it will become active when the switch is grounded. ............
Other functions 6. Using GPI OUT To assign the function or parameter that you want to control, press the GPI IN SETUP popup button. The GPI IN SETUP popup window will appear. The GPI OUT ports of the GPI OUT connector allow you to control an external device by performing operations on the CL series console. 1. Connect an external device to the CL series console’s GPI connector. 2. In the function access area, press the SETUP button to access the SETUP screen. 3. Press the MIDI/GPI button.
Other functions 3 GPI OUT SETUP popup button Press this button to open the GPI OUT SETUP popup window. The button shows the name of the currently selected function or parameter. 4 TEST button 7. In each field, select the desired function or parameter. 8. When you have finished making settings, press the OK button. 9. Repeat steps 5 through 8 to specify functions and parameters for other ports. While this is on, the corresponding GPI OUT port will be active and will output a control signal. 5. 6.
Other functions 4. 4 THRESHOLD field Press the FADER START tab to access the FADER START page. The following items are displayed. • UPSTROKE/DOWNSTROKE knobs These specify the level that will be the threshold for outputting a trigger signal. A trigger signal will be output when the fader exceeds the UPSTROKE level, or when the fader falls below the DOWNSTROKE level. If FADER TALLY is selected as the fader mode, UPSTROKE and DOWNSTROKE specify the level range for which a trigger signal will be output.
Other functions The following illustration shows how the signal that is output from the GPI OUT port will change in each fader mode when a fader is operated. In this example, UPSTROKE in the THRESHOLD field is set to –60.00, and DOWNSTROKE is set to –∞. (This illustration shows the case in which is selected as the polarity of the GPI OUT port. If the polarity is , the polarity of the output signal will be reversed.
Appendices Appendices # EQ Library List # 01 Bass Drum 1 LOW L-MID H-MID HIGH PEAKING PEAKING H.SHELF G +3.5 dB –3.5 dB 0.0 dB +4.0 dB F 100 Hz 265 Hz 1.06 kHz 5.30 kHz 1.25 10.0 0.90 — PEAKING PEAKING PEAKING LPF G +8.0 dB –7.0 dB +6.0 dB ON F 80.0 Hz 400 Hz 2.50 kHz 12.5 kHz Q 03 Snare Drum 1 0.0 dB +3.0 dB +4.5 dB 132 Hz 1.00 kHz 3.15 kHz 5.00 kHz 1.25 4.5 0.11 — L.SHELF PEAKING PEAKING PEAKING G +1.5 dB –8.5 dB +2.5 dB +4.
Appendices # 32 Total EQ 3 34 Snare Drum 3 36 Piano 3 38 Piano High 40 Narrator HIGH PEAKING PEAKING H.SHELF +0.5 dB +2.0 dB +4.0 dB F 67.0 Hz 850 Hz 1.90 kHz 15.0 kHz — 0.28 0.70 — PEAKING PEAKING PEAKING PEAKING G +3.5 dB –10.0 dB +3.5 dB 0.0 dB F 118 Hz 315 Hz 4.25 kHz 20.0 kHz Q 2.0 10.0 0.40 0.40 PEAKING L.SHELF PEAKING PEAKING G 0.0 dB +2.0 dB +3.5 dB 0.0 dB F 224 Hz 560 Hz 4.25 kHz 4.00 kHz — 4.5 2.8 0.10 L.SHELF PEAKING PEAKING H.
Appendices # Title Type 18 E. B. Slap COMPRESSOR 19 Syn. Bass COMPRESSOR 20 Piano1 COMPRESSOR 21 Piano2 COMPRESSOR 22 E. Guitar COMPRESSOR 23 A.
Appendices ■ DUCKING Ducking is commonly used for voice-over applications in which the background music level is reduced automatically when an announcer speaks. When the KEY IN source signal level exceeds the specified THRESHOLD, the output level is attenuated by a specified amount (RANGE). Dynamics Parameters Input channels provide DYNAMICS section 1 and DYNAMICS section 2. Output channels provide DYNAMICS section 1.
Appendices ■ EXPANDER An expander attenuates signals below a specified THRESHOLD by a specified RATIO. ■ COMPRESSOR The COMP processor attenuates signals above a specified THRESHOLD by a specified RATIO. The COMP processor can also be used as a limiter, which, with a RATIO of ∞:1, reduces the level to the threshold. This means that the limiter’s output level never actually exceeds the threshold.
Appendices ■ COMPANDER HARD (COMPANDER-H), COMPANDER SOFT (COMPANDER-S) The hard and soft companders combine the effects of the compressor, expander and limiter. Effect Type List Output Level Title Type Description REV-X Hall REV-X HALL REV-X Room REV-X ROOM REV-X Plate REV-X PLATE New reverb algorithm that delivers dense and rich reverberation, smooth decay, and provides a spaciousness and depth that enhances the original sound.
Appendices Title Delay+Rev Type Effects Parameters Description DELAY+REV Delay and reverb in parallel DelayRev DELAYREV Delay and reverb in series DistDelay DISTDELAY Distortion and delay in series Multi Filter MULTI FILTER 3-band parallel filter (24 dB/octave) Freeze FREEZE Simple sampler Distortion DISTORTION Distortion Amp Simulate AMP SIMULATE Guitar amp simulation Comp276 COMP276 This compressor emulates the characteristics of an analog compressor that has become a sought-
Appendices ■ STEREO REVERB Two input, two output stereo reverb. Parameter ■ GATE REVERB, REVERSE GATE One input, two output early reflections with gate, and early reflections with reverse gate. Range Description Parameter Range 0.3–99.0 s Reverb time TYPE REV TYPE Hall, Room, Stage, Plate Reverb type ROOMSIZE 0.1–20.0 INI. DLY 0.0–100.0 ms Initial delay before reverb begins LIVENESS 0–10 Early reflections decay characteristics (0 = dead, 10 = live) HI. RATIO 0.1–1.
Appendices ■ MOD.DELAY One input, two output basic repeat delay with modulation. Parameter ■ ECHO Two input, two output stereo delay with crossed feedback loop. Range Description Parameter Range Description DELAY 0.0–2725.0 ms Delay time DELAY L 0.0–1350.0 ms Left channel delay time FB. GAIN –99 to +99% Feedback gain (plus values for normal-phase feedback, minus values for reverse-phase feedback) DELAY R 0.0–1350.0 ms Right channel delay time FB.DLY L 0.0–1350.
Appendices ■ FLANGE Two input, two output flange effect. Parameter ■ PHASER Two input, two output 16-stage phaser. Range FREQ. 0.05–40.00 Hz DEPTH MOD. DLY Description Parameter Range Description Modulation speed FREQ. 0.05–40.00 Hz Modulation speed 0–100% Modulation depth DEPTH 0–100% Modulation depth 0.0–500.0 ms Modulation delay time FB. GAIN –99 to +99% FB.
Appendices ■ DYNA.PHASER Two input, two output dynamically controlled phaser. Parameter ■ DUAL PITCH Two input, two output pitch shifter. Range SOURCE INPUT, MIDI SENSE DIR.
Appendices ■ RING MOD. Two input, two output ring modulator. ■ AUTOPAN Two input, two output autopanner. Parameter FREQ. Range 0.05–40.00 Hz Description Parameter Range Modulation speed SOURCE OSC, SELF Description Modulation source: oscillator or input signal DEPTH 0–100% Modulation depth OSC FREQ 0.0–5000.0 Hz Oscillator frequency DIR. *1 Panning direction FM FREQ. 0.05–40.
Appendices ■ REV+CHORUS One input, two output reverb and chorus effects in parallel. Parameter Range REV TIME 0.3–99.0 s INI. DLY HI. RATIO ■ REV+FLANGE One input, two output reverb and flanger effects in parallel. Description Parameter Range Description Reverb time REV TIME 0.3–99.0 s Reverb time 0.0–500.0 ms Initial delay before reverb begins INI. DLY 0.0–500.0 ms Initial delay before reverb begins 0.1–1.0 High-frequency reverb time ratio HI. RATIO 0.1–1.
Appendices ■ REV+SYMPHO. One input, two output reverb and symphonic effects in parallel. Parameter Range ■ REVPAN This is a 1-in/2-out series-connected reverb and auto-pan effect. Parameter Description Range Description Reverb time REV TIME 0.3–99.0 s 0.0–500.0 ms Initial delay before reverb begins INI. DLY 0.0–500.0 ms Initial delay before reverb begins 0.1–1.0 High-frequency reverb time ratio HI. RATIO 0.1–1.0 High-frequency reverb time ratio DIFF. 0–10 Spread DIFF.
Appendices ■ DELAYER. One input, two output delay and early reflections effects in series. Parameter Range ■ DELAY+REV One input, two output delay and reverb effects in parallel. Parameter Description Range Description Left channel delay time DELAY L 0.0–1000.0 ms Left channel delay time 0.0–1000.0 ms Right channel delay time DELAY R 0.0–1000.0 ms Right channel delay time 0.0–1000.0 ms Feedback delay time FB. DLY 0.0–1000.0 ms Feedback delay time FB.
Appendices ■ DISTDELAY One input, two output distortion and delay effects in series. Parameter ■ FREEZE One input, two output basic sampler. Range Description Parameter Range Description DST TYPE DST1, DST2, OVD1, OVD2, CRUNCH Distortion type (DST = distortion, OVD = overdrive) DRIVE 0–100 Distortion drive MASTER 0–100 Master volume TONE –10 to +10 Tone control N. GATE 0–20 Noise reduction SYNC OFF/ON Tempo parameter sync on/off DLY.
Appendices ■ AMP SIMULATE One input, two output guitar amp simulator. Parameter Range ■ COMP276S This effect emulates the characteristics of analog compressors that are widely used in recording studios. It produces a thick, strong frame sound suitable for drums and bass. You can link and control the L and R channel parameters.
Appendices ■ OPENDECK It emulates the tape compression created by two open reel tape recorders (a recording deck and a playback deck.) You can change the sound quality by adjusting various elements, such as the deck type, tape quality, playback speed, etc. ■ EQUALIZER601 This effect emulates the characteristics of 70’s analog equalizers. Re-creating the distortion of typical analog circuits will add drive to the sound. Parameter Range Description LO TYPE HPF-2/1, LSH-1/2 Type of EQ1 LO F 16.
Appendices Parameter Range Premium Rack Processor Parameters Description LIM.REL *1 Release time of the limiter LIM.KNEE 0–5 Knee of the limiter LIM.BYP OFF/ON Bypasses the limiter PRESENCE –10 to +10 Positive (+) values lower the threshold of the high band and raise the threshold of the low band. Negative (–) values do the opposite. If this is set to 0, the high, mid, and low bands will be affected in the same way. ■ Portico5033 This models an analog 5-band EQ made by the RND company.
Appendices ■ U76 This models a well-known vintage compressor/limiter used in a wide range of situations. Parameter Range ■ Dynamic EQ This is a newly developed equalizer that dynamically changes the EQ gain in response to the input signal, controlling the amount of EQ cut or boost in a way similar to a compressor or expander. Description Parameter Range Description INPUT –96.0 to 0.0 dB Input level OUTPUT –96.0 to 0.
Appendices Effects and tempo synchronization Example 2: When SYNC=ON, DELAY=250 ms, NOTE=8th note, you change TEMPO from 120 to 121 DELAY = NOTE x 4 x (60 / new TEMPO) = (1/8) x 4 x (60/121) = 0.2479 (sec) = 247.9 (ms) Thus, the TEMPO will change from 250 ms to 247.9 ms. *a Rounded values are used for the calculation results. Some effects of the CL series can be synchronized with the tempo. There are two such types of effect; delay-type effects and modulation-type effects.
Appendices Parameters that can be assigned to control changes Mode Parameter 1 Parameter 2 MATRIX 1 POINT – MATRIX 8 POINT Mode NO ASSIGN Parameter 1 INPUT MATRIX 1 LEVEL L – MATRIX 8 LEVEL L MATRIX 1 POINT – MATRIX 8 POINT OUTPUT MIX 1–MIX 24 MATRIX 1–MATRIX 8 STEREO L–MONO(C) INPUT CH 1–CH 72*1 STIN1L–STIN8R OUTPUT MIX 1–MIX 24 MATRIX 1–MATRIX 8 STEREO L–MONO(C) MATRIX 1 ON – MATRIX 8 ON STEREO TO MATRIX MATRIX 1/2 PAN – MATRIX 7/8 PAN ON LOW Q LOW FREQ OUTPUT MIX 1–MIX 24 MATRIX 1–MATRI
Appendices Mode OUTPUT ATT Parameter 1 OUTPUT Parameter 2 Mode MIX1-MIX24 MATRIX1-MATRIX8 STEREO L-MONO(C) GEQ ON PREMIUM RACK A THRESHOLD RANGE PREMIUM RACK B HOLD H INPUT DYNAMICS1 DECAY/RELEASE H CH 1–CH 72*1 STIN1L–STIN8R ON B GAIN A 1 – GAIN A 31 BYPASS PARAM 1 H – PARAM 64 L BYPASS PARAM 1 H – PARAM 64 L MUTE MASTER KNEE/WIDTH FADER H Rack1–8 DCA 1–DCA 16 ON MASTER 1–MASTER 8 ON CH 1–CH 72*1 STIN1L–STIN8R MIX 1–MIX 24 MATRIX 1–MATRIX 8 STEREO L–MONO(C) GEQ RACK 1A–16B EFFECT RACK
Appendices NRPN parameter assignments Parameter INPUT FADER MIX1-20, MATRIX, STEREO LR MIX9 SEND MIX10 SEND MIX11 SEND MIX12 SEND INPUT to MIX9-16 LEVEL MIX13 SEND MIX14 SEND MIX15 SEND MIX16 SEND MATRIX1 SEND MATRIX2 SEND INPUT to MATRIX1-4 LEVEL MATRIX3 SEND MATRIX4 SEND MATRIX1 SEND MATRIX2 SEND MATRIX3 SEND MATRIX4 SEND MIX1-20, STEREO LR to MATRIX LEVEL MATRIX5 SEND MATRIX6 SEND MATRIX7 SEND MATRIX8 SEND INPUT ON MIX1-20, MATRIX, STEREO LR MIX9 SEND MIX10 SEND MIX11 SEND MIX12 SEND INPUT to MIX9-16 ON
Appendices Parameter MIX9/10 INPUT to MIX9/10-15/16 MIX11/12 PAN MIX13/14 MIX15/16 MATRIX1/2 INPUT to MATRIX1/2, 3/4 PAN MATRIX3/4 MATRIX1/2 MATRIX3/4 MIX1-20, STEREO LR to MATRIX PAN MATRIX5/6 MATRIX7/8 MIX1-8 to STEREO PAN MIX TO ST MIX1-20, MATRIX, BALANCE STEREO LR MATRIX1 SEND MATRIX2 SEND MATRIX3 SEND MIX, STEREO LR, MONO MATRIX4 SEND to MATRIX PRE/POST MATRIX5 SEND MATRIX6 SEND MATRIX7 SEND MATRIX8 SEND MATRIX1 SEND MATRIX2 SEND MATRIX3 SEND MATRIX4 SEND MIX21-24, MONO to MATRIX ON MATRIX5 SEND MATRI
Appendices Parameter MATRIX1 SEND MATRIX2 SEND MATRIX3 SEND MATRIX4 SEND MIX21-24, MONO to MATRIX LEVEL MATRIX5 SEND MATRIX6 SEND MATRIX7 SEND MATRIX8 SEND ON MIX21-24, MONO MIX1 SEND MIX2 SEND MIX3 SEND MIX4 SEND INPUT1-56, STIN1-4 to MIX1-8 ON MIX5 SEND MIX6 SEND MIX7 SEND MIX8 SEND MATRIX5 SEND MATRIX6 SEND INPUT1-56, STIN1-4 to MATRIX5-8 ON MATRIX7 SEND MATRIX8 SEND MIX9-24 to STEREO ON MIX TO ST INSERT MIX21-24, MONO MIX1 SEND MIX2 SEND MIX3 SEND MIX4 SEND INPUT1-56, STIN1-4 to MIX1-8 PRE/POST MIX5 SEN
Appendices Parameter EXTERNAL GAIN1 INPUT GAIN 1 EXTERNAL GAIN2 INPUT GAIN 2 EXTERNAL GAIN3 INPUT GAIN 3 EXTERNAL GAIN4 INPUT GAIN 4 EXTERNAL GAIN5 INPUT GAIN 5 EXTERNAL GAIN6 INPUT GAIN 6 EXTERNAL GAIN7 INPUT GAIN 7 EXTERNAL GAIN8 INPUT GAIN 8 EXTERNAL +48V 1 INPUT +48V 1 EXTERNAL +48V 2 INPUT +48V 2 EXTERNAL +48V 3 INPUT +48V 3 EXTERNAL +48V 4 INPUT +48V 4 HA EXTERNAL +48V 5 INPUT +48V 5 EXTERNAL +48V 6 INPUT +48V 6 EXTERNAL +48V 7 INPUT +48V 7 EXTERNAL +48V 8 INPUT +48V 8 EXTERNAL HPF1 INPUT HPF1 EXTERNA
Appendices Mixing parameter operation applicability This table indicates which settings affect the behavior of each input channel and output channel parameter. It also indicates whether or not they can be linked as stereo, and whether or not they are relevant to the RECALL SAFE, GLOBAL PASTE, and USER LEVEL settings, and a channel library.
Appendices Parameter Stereo*1 CHANNEL LINK RECALL SAFE, FOCUS RECALL, GLOBAL PASTE*8 ALL Parameter Select button USER LEVEL Channel Library Pan/balance O*11 O INPUT TO ST INPUT FADER/ON O Pan Mode O O *5 INPUT PROCESSING O On O TO STEREO O *5 INPUT PROCESSING O CSR O TO STEREO O *5 INPUT PROCESSING O Mode O TO STEREO O *5 INPUT PROCESSING O On O INPUT CH ON O INPUT CH ON INPUT FADER/ON O Fader O*10 INPUT FADER*10 O INPUT FADER INPUT FADER/ON O LCR Mute
Appendices ■ MIX Channels Parameter Linked for a stereo pair RECALL SAFE, FOCUS RECALL, GLOBAL PASTE *8, *12 ALL Parameter Select button USER LEVEL Name, Icon, Color O MIX NAME, GLOBAL OUTPUT NAME OUTPUT NAME Output Patch O MIX OUTPUT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH Out Patch O MIX INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH In Patch O MIX INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH +48V, Gain, Gain Compensation O MIX INSERT PATCH, GLOBAL HA MIX PROCESSING Insert Cha
Appendices ■ MATRIX Channels Parameter Linked for a stereo pair RECALL SAFE, FOCUS RECALL, GLOBAL PASTE *8, *12 ALL Parameter Select button USER LEVEL Name, Icon, Color O MATRIX NAME,GLOBAL OUTPUT NAME OUTPUT NAME Output Patch O MATRIX OUTPUT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH Insert Out Patch O MATRIX INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH In Patch O MATRIX INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH +48V, Gain, Gain Compensation O MATRIX INSERT PATCH, GLOBAL HA MA
Appendices ■ STEREO, MONO Channels Linked for a stereo pair Parameter RECALL SAFE, FOCUS RECALL, GLOBAL PASTE *8, *12 ALL Name, Icon, Color O STEREO, MONO NAME, GLOBAL OUTPUT NAME Output Patch O STEREO, MONO OUTPUT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH Out Patch O STEREO, MONO INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH In Patch O STEREO, MONO INSERT PATCH, GLOBAL OUTPUT PATCH OUTPUT PATCH Insert +48V, Gain, Gain Compensation Channel Library USER LEVEL Parameter Select button OUT
Appendices Functions that can be assigned to USER DEFINED keys FUNCTION PARAMETER 1 PARAMETER 2 Explanation DYNAMICS LIBRARY FUNCTION NO ASSIGN PARAMETER 1 PARAMETER 2 Explanation INPUT EQ LIBRARY — — No assignment. LATCH — Toggle ALTERNATE FUNCTION each time it is pressed. UNLATCH — Switch to ALTERNATE FUNCTION only while pressed. BRIGHTNESS BANK CHANGE — Toggle between the brightness settings stored in A and B. CH ON SPECIFIC CH *4) Switch the CH ON/OFF.
Appendices FUNCTION PARAMETER 1 PARAMETER 2 Explanation FUNCTION PARAMETER 1 OUTPUT EFFECT RACK1–8 PARAMETER 2 Switch MONITOR on/off. — While holding down this key, press the SEL key of a MIX or MATRIX channel to switch the assignment on/off. During this time, the [SEL] LED will be lit if assign is ON, or dark if OFF. The assignment setting made while holding down this key will be stored. Pressing the key again will recall the stored setting.
Appendices FUNCTION PARAMETER 1 PARAMETER 2 BOOKMARK PAGE CHANGE NEXT PAGE CLOSE POPUP TRANSPORT RECORDER — Display the previous/next page. — Close the displayed popup window. PLAY/PAUSE, STOP, FF/NEXT, REW/PREVIOUS, REC Display the previous/next page. AUTO REC Shortcut function for STOP → REC → PLAY. Recording will be initiated in a single action. If this is executed during recording, the file being recorded will first be closed, and then recording will continue with a new file.
Appendices Functions that can be assigned to USER DEFINED knobs FUNCTION PARAMETER 1 FUNCTION PARAMETER 2 NO ASSIGN LAMP *10) HPF FREQUENCY *4) I/O DEVICE GAIN1–GAIN32 *11) INPUT DELAY DELAY TIME *3) INPUT GAIN MIDI CONTROL CHANGE DCA TRIM MONITOR OUTPUT PFL TRIM RATIO OSCILLATOR ATTACK OUTPUT PORT OUTGAIN KNEE *13) THRESHOLD RATIO FREQUENCY *4) DELAY TIME GAIN *12) TO MIX LEVEL MIX1–MIX24 *3) TO MATRIX LEVEL MATRIX1–MATRIX8 *7) TO MIX PAN MIX1/2–MIX23/24 *3) TO MATRIX
Appendices Functions that can be assigned to the assignable encoders PAN GAIN ASSIGN O FUNCTION PAN/BALANCE PARAMETER 1 *1 PARAMETER 2 PAN *2 *3 BAL O ANALOG GAIN A.GAIN *1 O DIGITAL GAIN D.
Appendices MIDI Data Format This section explains the format of the data that the CL series is able to understand, send, and receive. STATUS DATA 0vvvvvvv vv Control Value (0-127) 1011nnnn Bn Control change 20 Control number (32) 0vvvvvvv vv Control Value (0-127) If [TABLE] is selected 1 CHANNEL MESSAGE 1.1 NOTE OFF STATUS DATA (8n) Reception These messages are echoed to MIDI OUT if [OTHER COMMAND ECHO] is ON. They are received if [Rx CH] matches, and used to control effects.
Appendices 2 SYSTEM REALTIME MESSAGE < MMC DEFERED PLAY > 2.1 SONG SELECT Reception If the [DEVICE NO.] matches or is 7F, receives this message and starts playback. (F3) Reception Select the track number shown in the TITLE LIST screen of the USB memory recorder. STATUS 11110011 F3 Song select Song number 0sssssss ss Song number (0-127) 2.2 TIMING CLOCK (F8) Reception This message is used to control effects. This message is transmitted twenty-four times per quarter note.
Appendices [Conversion from actual data to bulk data] d[0-6]: actual data b[0-7]: bulk data b[0] = 0; for( I=0; I<7; I++){ if( d[I]&0x80){ b[0] |= 1<<(6-I); } b[I+1] = d[I]&0x7F; } [Recovery from bulk data to actual data] d[0-6]: actual data b[0-7]: bulk data for( I=0; I<7; I++){ b[0] <<= 1; d[I] = b[I+1]+(0x80&b[0]); } 3.3 PARAMETER CHANGE Reception This message is echoed if [PARAMETER CHANGE ECHO] is ON.
Appendices 4.2.
Appendices 4.4 FUNCTION CALL – LIBRARY ATTRIBUTE – 4.4.2 Format (PARAMETER REQUEST) 4.5 EXIST LIBRARY RANGE 4.4.1 Format (PARAMETER CHANGE) Receive The PARAMETER CHANGE will be sent with Device number [Rx CH] immediately the data is received. 4.5.1 Format (PARAMETER CHANGE) Receive Data will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [PARAMETER CHANGE ECHO] is on.
Appendices 4.5.2 Format (PARAMETER REQUEST) 4.6 FUNCTION CALL – COLLECTION STORE – Receive The PARAMETER CHANGE will be sent with Device number [Rx CH] immediately the data is received. 4.6.1 Format (PARAMETER CHANGE) STATUS ID No.
Appendices 4.8 FUNCTION CALL – CHANNEL – 4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE) Receive Data will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [PARAMETER CHANGE ECHO] is on. STATUS ID No.
Appendices Warning/Error Messages Message Message Meaning Meaning File Already Exists! The USB flash drive already contains a file/directory with the same name as the one you are attempting to save, rename, or create. File Error [xx]! Internal file access error File Protected! Overwriting was not possible because the file on the USB flash drive is write-protected. xxx Parameters Copied. Parameter xxx was copied to the copy buffer. xxx Parameters Initialized. Parameter xxx was initialized.
Appendices Message Meaning Message Meaning STAGEMIX: Tx Buffer Full! Too much data is being transmitted from the StageMix output port. Storage Full! The file could not be saved because there is insufficient space on the USB flash drive. Storage Not Found! The USB flash drive could not be recognized. Storage Not Ready! Access is not possible because the USB flash drive is not ready. Sync Error! [xxx] The CL series console is not synchronized to the [xxx] signal. Tap Operation Ignored.
Appendices ■ Dynamic Range. Electrical characteristics Input All faders are nominal when measured. Output impedance of signal generator:150ohms OMNI IN 1-8 — ■ Frequency Response. Input OMNI IN 1-8 Fs= 44.1 kHz or 48 kHz @20 Hz–20 kHz, referenced to the nominal output level @1 kHz Output RL OMNI OUT 1-8 600 Ω PHONES Conditions GAIN: +66dB 8Ω ■ Gain Error.
Appendices Mixer Basic Parameters Function Parameter ■ Output Function Type: Gate/Ducking/Comp/Expander Threshold= Gate: –72 dB to 0 dB Others: –54 dB to 0 dB ■ Libraries Name Number Total Ratio= Preset 1 + User 300 301 Attack= 0 msec to 120 msec Input CH Library Preset 1 + User 199 200 Hold= Output CH Library Preset 1 + User 199 200 Input EQ Library Preset 40 + User 159 199 Output EQ Library Preset 3 + User 196 199 Dynamics Library Preset 41 + User 158 199 Effect Library Prese
Note On Note Off Key’s Ch’s Velocity After Touch 275 O: Yes X: No Mode 2: OMNI ON, MONO Mode 4: OMNI OFF, MONO Effect Control Mode 1: OMNI ON, POLY Mode 3: OMNI OFF, POLY Aux Messages X X X X O O IDI Implementation Chart Recorder Control Assignable Bank Select Data Entry NRPN LSB,MSB Assignable Cntrl Effect Control *1 Bulk Dump/Request and Parameter Change/Request.
Appendices Index F M R Factory set........................................................ 206 Fade function..................................................... 91 Focus function................................................... 87 Function Tree...................................................... 4 Recall Safe function.......................................... 88 Recall scenes.............................................. 80, 152 Gain ..............................................................
Yamaha Pro Audio Global Web Site http://www.yamahaproaudio.com/ Yamaha Manual Library http://www.yamaha.co.jp/manual/ C.S.G.