User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Graphic EQ, effects, and Premium Rack
Reference Manual
133
6 LMF/MF/HMF IN button
Turn LMF/MF/HMF EQ on or off respectively.
7 LF/HF IN button
Turn LF and HF EQ on or off simultaneously.
8 Graph
Indicates the graphical EQ response.
■ Portico 5043
Portico 5043, like Portico 5033, is a processor that emulates RND’s analog compressor.The actual 5043
Compressor is equipped with the same input/output transformer as that of the 5033 EQ, delivering a
natural, analog-like tonality and effect. It enables you to obtain a range of results from hard
compression to natural sound, and is suitable for a broad range of audio sources ranging from drums
to vocals. The most notable feature of this model is that you can switch the gain reduction type. You can
choose either an FF (Feed-Forward) circuit type (which is the current mainstream), or an FB (Feed-
Back) circuit which was typically used in vintage compressors. This allows you to create sounds with
various characteristics as appropriate for your applications.
1 IN button
Turns the compressor’s bypass on or off. When the compressor is bypassed, the button indicator
will turn off. However, even if the compressor is bypassed, the signal will pass through the input/
output transformer and amp circuits.
2 INPUT meter
Indicates the input signal level.
One meter appears in DUAL mode, and two meters appear in STEREO mode.
3 FB button
Switches the gain reduction method between FF (Feed-Forward) circuit and FB (Feed-Back)
circuit. The button will light when FB circuit is selected.
The FF circuit is used in most contemporary compressors. This type is useful when you want to
apply compression thoroughly while maintaining a consistent tonal color.
The FB circuit is used in vintage compressors. This type is suitable when you want to apply a
smooth compression while adding a tonal color that is characteristic to the device.
4 GAIN REDUCTION meter
Indicates the amount of gain reduction.
5 THRESHOLD knob
Adjusts the threshold at which compression starts to be applied.
6 RATIO knob
Adjusts the compression ratio. Fully rotate the knob clockwise to switch to the limiter.
7 ATTACK knob
Adjusts the compressor’s attack time.
8 RELEASE knob
Adjusts the compressor’s release time.
9 GAIN knob
Adjusts the output gain.