User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Scene memory
Reference Manual
90
On-screen buttons and corresponding parameters apply to the following channels:
0 SAFE PARAMETER SELECT field (DCA)
Enables you to select parameters for a DCA group that will be affected by Recall Safe operations.
If the ALL button is on, all DCA master parameters will be subject to Recall Safe. If LEVEL/ON
is on, the DCA master level and on/off status will be subject to Recall Safe.
3. To select the channel or DCA group that will be affected by Recall Safe operations,
press the corresponding [SEL] key.
The corresponding channel or DCA group will be enclosed by a white frame in the CH RECALL
SAFE field. (However, this white frame does not mean that the Recall Safe setting is now enabled.)
The selected channel or DCA groups 1–8 or 9–16 will be recalled to the SAFE PARAMETER
SELECT field.
NOTE
If the CH RECALL SAFE field’s SET BY SEL button is on, Recall Safe will be enabled when you
press the [SEL] key, and the corresponding channel or DCA group will be highlighted in the CH
RECALL SAFE field. You can select parameters as described in step 4 even after turning Recall
Safe on.
4. If you want to enable Recall Safe for specific parameters of the selected channel or
DCA group, make the following settings in the SAFE PARAMETER SELECT field.
NOTE
• Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on or off,
you must also perform the operation described in step 5 (see page 91).
• While the APPLY TO ALL INPUT button (or the APPLY TO ALL OUTPUT button) is on, operations
in the SAFE PARAMETER SELECT field will apply to all input channels (or output channels).
• If an input channel is selected:
Use the buttons in the lower part of the SAFE PARAMETER SELECT field (except for the “ALL”
button) to select the parameters that will be subject to Recall Safe (multiple selections are
allowed). If you want all parameters to be subject to Recall Safe, turn on the ALL button (this is
the default setting).
• If a ST IN channel is selected:
Use the same steps as those for an input channel. (Different buttons will be displayed.)
• If a MIX channel is selected:
Use the buttons in the lower part of the SAFE PARAMETER SELECT field (except for the “ALL”
button) to select the parameters that will be subject to Recall Safe (multiple selections are allowed).
In addition, you can use the WITH MIX SEND button displayed in the lower left of the field to enable
Recall Safe for the on/off status and send level of signals sent from input channels to MIX buses.
If you want all parameters shown in the lower part of the field to be subject to Recall Safe, turn on
the ALL button (this is the default setting).
• If a MATRIX channel is selected:
Use the same steps as those for a MIX channel. (Different types of buttons will be displayed.)
• If a DCA group is selected:
If you press a [SEL] key for a DCA group, all parameters for the DCA groups (selected from DCA
groups 1–8 and DCA groups 9–16) will be displayed simultaneously. For the parameters that will
be subject to Recall Safe, you can select either “ALL” or “LEVEL/ON” (fader position and on/off
status of the [ON] key). Recall Safe will be enabled when you make this selection.
If you want all parameters of the DCA group to be subject to Recall Safe, turn on the ALL button.
Unlike when a channel is selected, Recall Safe will be enabled for that DCA group the moment
you turn on either the LEVEL/ON button or the ALL button.
Button name Corresponding parameter
Input
channel
MIX
channel
MATRIX
channel
STEREO/
MONO
channel
WITH MIX SEND Send level to the MIX bus O
WITH MATRIX SEND Send level to MATRIX bus O
ALL All parameters O O O O
HA HA-related settings O
HPF HPF settings O
EQ EQ settings O O O O
DYNA 1 Dynamics 1 settings O O O O
DYNA 2 Dynamics 2 settings O
MIX SEND Send level to MIX bus O
MATRIX SEND Send level to MATRIX bus O O O
FADER Fader settings O O O O
CH ON [ON] key settings O O O O
TO ST
On/off setting for STEREO bus
assignment, PAN, etc.
OO
MONO
On/off setting for MONO bus
assignment
OO
INPUT PATCH Input Patching O
DIGITAL GAIN Digital gain settings O
INSERT Insert on/off
O
*1
*1. ST IN channels do not feature these buttons.
OOO
INSERT PATCH Insert patch settings
O
*1
OOO
DIRECT OUT Direct Out settings
O
*1
MIX ON MIX Send On/Off O
MATRIX ON MATRIX Send On/Off O O O
DELAY Delay settings O
NAME Channel name O O O O
OUTPUT PATCH Output Patching O O O
BAL BLANCE parameter settings O
O
(stereo only)