Technical data
This program enables or disables only the USB interface on the
front panel.
9.8 Autologin
If "mkautolg.vbs" (in the C:\Support\IPCMaintenance\ directory) is called, the
user "Rexroth" is entered as Autologin with his password. Please observe that
the user "Rexroth" has administrator rights.
9.9 Analog VGA Monitor
Calling "InstallVSAnalogMonSupport.cmd" on VS devices allows the connec‐
tion of an analog monitor to the VGA interface of the basis device at any time
and the immediate display of the screen contents.
9.10 M-Key-UpperClassFilter
9.10.1 General Information
From firmware version 02VRS and higher, the M-Key-UpperClassFilter driver
is installed and active ex works. The M-Key-UpperClassFilter driver is used for
maintaining the downward compatibility of the M-Key-Code when existing soft‐
ware products are used on devices of the Vxx.3 generation. The incoming
keyboard data stream is analyzed and as soon as a M-key-code (F13-F24,...)
is detected, the corresponding Ctrl-LRShift-Alt-<n> code is inserted in the data
stream. This is done in the kernel level of the operating system.
If a USB special keyboard is used, it may be required to deactivate
the M-Key-UpperClassFilter, see chapter 9.10 "M-Key-Upper‐
ClassFilter" on page 82.
9.10.2 Activating and Deactivating the M-Key-UpperClassFilter
For activating and deactivating use the batch files mkeyfilter-acti-
vate.cmd and mkeyfilter-deactivate.cmd. After the execution of the
batch files the system restarts. The batch files are in the Support ▶ MKey-Filter
Driver directory.
9.11 RAID
9.11.1 General Information
The RAID system can be used either for better data security or for fast access.
RAID means "Redundant Array Of Independent Disks".
If the VSx.3 device was ordered as RAID1 system, no further settings are to be
made in the BIOS.
The values in the "Default settings" of the BIOS refer to a VSx.3 device with
one hard disk (HDD or SSD). If the "Default settings" are loaded at an existing
RAID1 system, the RAID1 system can be recovered with the following meas‐
ures.
9.11.2 Installing RAID1 System in the BIOS
To install a RAID1 system in a VSx.3 device, the following BIOS entries are
required:
1. Start the BIOS during booting with the <Del> key.
82/101 Bosch Rexroth AG | Electric Drives