Technical data

Fig.9-10: Configuration dialog of the UPS NT software
Enable VPx Simple Mode
VPx.3 devices can be operated in a "simple UPS mode" without communication
interface. During simple UPS operation the UPS receives only the command
for switching off the control. Further functions are not available in this mode and
therefore they are hidden in this dialog.
Com Port
With "Select COM Port" the (virtual) serial communication interface to be con‐
nected to the UPS can be selected. The delivery setting is COM3. This setting
corresponds to the USB port XUSB2.
In new systems the UPS can be connected to any interface as the
software automatically identifies this interface. There is a defined
assignment of the UPS to the USB interface for firmware version
01VRS.
Advanced Controls
Shutdown Delay Time
With "Shutdown Delay Time" the delay time for the shutdown is defined.
During this period of time the user can backup his data. If the data is not
saved, the applications end after the specified time without any confirma‐
tion dialog!
Enable Startup Accu Test
If "Enable Startup Accu Test" is selected, the UPS battery is tested during
each system restart. If an error occurs during the test, a corresponding
message is displayed.
Disable UPS
If "Disable UPS" is selected, the UPS function is switched off. Only rea‐
sonable for testing and installation purposes.
Default