4.4.9 PEF
Platform Event Filtering (PEF)
provides a mechanism for conguring the BMC to take
selected actions on event messages that it receives or has internally generated. These
actions include operations such as system power-off, system reset, as well as triggering the
generation of an alert. A PEF implementation is recommended to provide at least 16 entries
in the event lter table. A subset of these entries should be pre-congured for common
system failure events, such as over-temperature, power system failure, fan failure events, etc.
To open PEF Management Settings page, click
Configurations > PEF
from the main menu.
A sample screenshot of PEF Management Settings Page is shown in the screen shot below.
1. PEF ID: This eld displays the ID for the newly congured PEF entry (read-only).
2. Filter configuration: Check box to enable the PEF settings.
3. Event Filter Action: Check box to enable PEF Alert action. This is a mandatory eld.
4. Event Severity: To choose any one of the Event severity from the list.
5. Sensor Name: To choose the particular sensor from the sensor list.
6. Add: To add the new event lter entry and return to Event lter list.
7. Modify: To modify the existing entries.
8. Cancel: To cancel the modication and return to Event lter list.