User Manual User guide

570 Security module dev port setup Inspect cable from main board assembly to the security module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, replace the security module.
571 Invalid default transaction
TBD
572 SPED key from pad cmd aborted by
user
Inspect cable from docking board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, it may be necessary to replace the main board, the
docking board, the SPED module or related cabling.
573 SPED keys from pad cmd verify failed
Inspect cable from docking board assembly to the SPED module for
damage. Make sure
that the cable is connected at both ends.
Restart ATM. Clear the error. If error persists, it may be necessary
to replace the main board, the docking board, the SPED module or
related cabling.
574 SNA comms error To be determined
575 Timeout waiting to send command to
dispenser
Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.
576 Timeout waiting to receive response
from dispenser
Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.
577 Card reader disabled Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.
578 Card reader present timeout Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.
579 SPED - Enable keypad command failed Inspect cable from docking assembly to the SPED Module for damage. Make
sure that the cable is connected at both ends. Verify that the DC operating
voltages are correct. Restart ATM. Clear the error. If error persists, replace
the SPED module.
580 SPED - Disable keypad command failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
581 SPED - Enable key from pad module
failed
Inspect cable from docking assembly to the SPED Module for
damage. Mak
e sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
582 SPED - Disable key from pad module
Inspect cable from docking assembly to the SPED Module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
583 SPED - Enable PIN entry mode failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
584 SPED - Disable PIN entry mode failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
35