User Manual User guide

615 ERR SPED TAMPER STATUS GRID
Inspect cable from main board assembly to the SPED module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
616 ERR SPED TAMPER STATUS
VOLTAGE
Inspect cable from main board assembly to the SPED module for
damage. Mak
e sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
617 ERR SPED SERIAL NUMBER
CHANGE
Inspect cable from main board assembly to the SPED module for
damage. Mak
e sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
618 SPED serial number change
Inspect cable from main board assembly to the SPED module for
damage. Make sure
that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
619 NMD 100 shutter failed after reset
Inspect cable from Dispenser CMC assembly to the Shutter
Assembly
for damage. Make sure that the cable is connected at
both ends. Verify that the DC operating voltages are correct.
Restart ATM. Clear the error. If the Error persists consider replacing
the cable between the Dispenser CMC Board and The Shutter
Assembly, the Shutter Assembly PCB, the Shutter Assembly or the
Dispenser CMC Assembly.
620 NMD 100 shutter OK after reset To be determined
38