Technical data
DANGER
Danger without protective separation!
The 24 VDC input voltage must comply with the requirements of the "Protective
separation"!
Plug and unplug the connector only if there is no voltage!
Interfering AC voltage components such as the ones resulting from an uncon‐
trolled three-phase bridge circuit without smoothing and with a ripple factor (see
DIN 40110/10.75, section 1.2) of 5 % are allowed.
That results in the greatest absolute value of 30.2 V as upper voltage limit. The
lowest absolute value of 18.5 V is the lower voltage limit.
For further information please refer to chapter 5.4 "Wiring" on page 29.
7.2.4 Serial Interface XCOM
XCOM – Serial interface
A serial standard interface is provided at the XCOM connection.
D-Sub male connector, 9-pin
Type RS232
Cable length 15 m max.
Cable type
Shielded, cross-section min. 0.14 mm
2
Transmission Rate Max. 115200 bits/s
Handshake Hardware and software handshake (XON, XOFF)
Interrupt (IRQ): 4
I/O address AUTO (or 3F8H)
BIOS presetting Enabled
Fig.7-5: Pin assignment COM
7.2.5 Settings of the Serial Interface
Control panel
For the transfer parameter settings of the serial interfaces, please refer to the
description of the installed operating system (for Windows under Start ▶ Set‐
tings ▶ Control Panel ▶ ...).
BIOS
The BIOS setting of COM (Serial Port A) is preset to AUTO (automatic param‐
eter assignment). Apply the following settings to assign the parameters directly:
Project Planning Manual | Rexroth IndraControl VSB 40.3 Electric Drives
and Controls
| Bosch Rexroth AG 39/101
PC Box