Technical data

7 PC Box
7.1 View on the Connector Panel
Fig.7-1: Position of the connections
7.2 Interfaces
7.2.1 General Information
Malfunctions due to insufficient shielding! Use only shielded cables
and metallic or conductive connector/coupling covers with large-
area shield support.
CAUTION
Material damages to electronics due to missing functional earth ground
connection!
Please ensure that the functional earth ground is connected, because other‐
wise the electronics can be destroyed by a potential difference between the
VDP xx.3 and the VSB 40.3 if the voltage supply is interrupted to only one device
and established again.
7.2.2 Overview
Labeling of
the housing
Connection type Connector type (inte‐
grated)
Mating connector or
cable (from outside)
X10 PC supply voltage: 24
VDC
Screw terminal See chapter chapter
7.2 "Interfaces" on
page 37
XCOM Serial interface:
RS232
D-Sub male connec‐
tor, 9-pin
D-Sub female con‐
nector, 9-pin
XUSB 1 to 8 8 USB interfaces USB female connec‐
tor, 4-pin, type A
USB male connector,
4-pin
Project Planning Manual | Rexroth IndraControl VSB 40.3 Electric Drives
and Controls
| Bosch Rexroth AG 37/101
PC Box