6 Display and Operating Components
6.1 Power Button
Next to the connector panel (see fig. 7-1 "Position of the connections" on page
37), a button labeled with "PWR" is provided.
Due to the default setting of the BIOS, the control cabinet PC starts when volt‐
age is applied. If you have changed this setting in the BIOS, the control cabinet
PC can be started via the "PWR" power button.
In order that the control cabinet PC starts again when a voltage is applied,
proceed as follows:
1. Start the BIOS setup by pressing <Del> while booting.
2. Change to the "Chipset" menu.
3. Select the setting "[Power On]" in "Restore on AC Power loss" under
"South Bridge Chipset + Configuration".
6.2 Display, Monitor and Keyboard
6.2.1 Display
To display and operate the VSB 40.3 we recommend the displays VDP 16.3
and VDP 40.3, especially designed for industrial applications by Bosch
Rexroth . The displays are connected with the VSB 40.3 via the CDI interface.
The VDP operator displays are equipped with a foil keyboard AND/or with a
touch screen.
Operate the touch screen only with a touch pen or your finger.
You can also connect mouse and keyboard to these displays.
6.2.2 VGA Monitor
A standard monitor (female connector XVGA) can be connected to the VSB
40.3.
6.2.3 Selection of the Graphics Driver
When the VSB device is delivered, the settings allow to trigger a connected
monitor and a connected VDP.
Activating the VDP or an external
monitor
If the VDP connected to the CDI interface, the external monitor operated at the
VGA connection or both are addressed, can be selected as follows:
1. Select "Intel(R) Extreme Graphics" in the task bar.
Fig.6-1: Intel® Extreme Graphics
2. Select Graphics Options ▶ Graphics Properties.
Project Planning Manual | Rexroth IndraControl VSB 40.3 Electric Drives
and Controls
| Bosch Rexroth AG 33/101
Display and Operating Components