Integrated Dell Remote Access Controller 9 Attribute Registry 2021 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: iDRAC Property Database Group and Object Descriptions...........................................83 New features added......................................................................................................................................................... 83 Firmware version 5.00.00.00................................................................................................................................... 83 Chapter 2: BIOS Attributes..............................
BIOS.BootSettings.SetBootOrderFqdd6 (Read or Write)................................................................................ 96 BIOS.BootSettings.SetBootOrderFqdd7 (Read or Write).................................................................................96 BIOS.BootSettings.SetBootOrderFqdd8 (Read or Write).................................................................................96 BIOS.BootSettings.SetBootOrderFqdd9 (Read or Write)........................................................
BIOS.DebugMenuSetting.BrowserOptionsRef (Read or Write).....................................................................108 BIOS.DebugMenuSetting.BugChecking (Read or Write).................................................................................108 BIOS.DebugMenuSetting.CETemperatureThresholdDebug (Read or Write)............................................. 108 BIOS.DebugMenuSetting.CEWarningThreshold (Read or Write).................................................................. 108 BIOS.
BIOS.DebugMenuSetting.RebootTestCount (Read or Write)........................................................................ 120 BIOS.DebugMenuSetting.RebootTestMode (Read or Write).........................................................................120 BIOS.DebugMenuSetting.RebootTestPoint (Read or Write).......................................................................... 121 BIOS.DebugMenuSetting.S4Support (Read or Write)..........................................................................
BIOS.HttpDev3Settings.HttpDev3Dns2 (Read or Write)................................................................................ 132 BIOS.HttpDev3Settings.HttpDev3DnsDhcpEnDis (Read or Write).............................................................. 132 BIOS.HttpDev3Settings.HttpDev3Gateway (Read or Write)......................................................................... 132 BIOS.HttpDev3Settings.HttpDev3Interface (Read or Write)..................................................................
BIOS.IntegratedDevices.EmbNicPort1BootProto (Read or Write)................................................................ 143 BIOS.IntegratedDevices.EmbNicPort2BootProto (Read or Write)............................................................... 143 BIOS.IntegratedDevices.EmbNicPort3BootProto (Read or Write)............................................................... 144 BIOS.IntegratedDevices.EmbNicPort4BootProto (Read or Write)...............................................................
BIOS.IntegratedDevices.UsbPorts (Read or Write).......................................................................................... 157 BIOS.IscsiDev1Con1Settings......................................................................................................................................... 158 BIOS.IscsiDev1Con1Settings.IscsiDev1Con1Auth (Read or Write).................................................................158 BIOS.IscsiDev1Con1Settings.IscsiDev1Con1ChapName (Read or Write).........
BIOS.IscsiDev1Con2Settings.IscsiDev1Con2VlanPriority (Read or Write)...................................................170 BIOS.IscsiDevice1Settings............................................................................................................................................. 170 BIOS.IscsiDevice1Settings.IscsiDev1Con1EnDis (Read or Write)................................................................... 170 BIOS.IscsiDevice1Settings.IscsiDev1Con1SettingsRef (Read or Write)....................
BIOS.MemSettings.DeviceLocator02 (Read or Write)..................................................................................... 181 BIOS.MemSettings.DeviceLocator03 (Read or Write)..................................................................................... 181 BIOS.MemSettings.DeviceLocator04 (Read or Write).....................................................................................182 BIOS.MemSettings.DeviceLocator05 (Read or Write)...................................................
BIOS.MemSettings.DimmSlot29 (Read or Write)..............................................................................................192 BIOS.MemSettings.DimmSlot30 (Read or Write)..............................................................................................192 BIOS.MemSettings.DimmSlot31 (Read or Write)...............................................................................................193 BIOS.MemSettings.DramRefreshDelay (Read or Write).......................................
BIOS.MemSettings.LockState19 (Read or Write).............................................................................................206 BIOS.MemSettings.LockState20 (Read or Write)............................................................................................206 BIOS.MemSettings.LockState21 (Read or Write).............................................................................................206 BIOS.MemSettings.LockState22 (Read or Write)..............................................
BIOS.MemSettings.NvdimmFirmwareVer3 (Read or Write)...........................................................................219 BIOS.MemSettings.NvdimmFirmwareVer4 (Read or Write).......................................................................... 220 BIOS.MemSettings.NvdimmFirmwareVer5 (Read or Write).......................................................................... 220 BIOS.MemSettings.NvdimmFirmwareVer6 (Read or Write).......................................................................
BIOS.MemSettings.NvdimmSize3 (Read or Write)........................................................................................... 231 BIOS.MemSettings.NvdimmSize4 (Read or Write)........................................................................................... 231 BIOS.MemSettings.NvdimmSize5 (Read or Write)...........................................................................................231 BIOS.MemSettings.NvdimmSize6 (Read or Write).................................................
BIOS.MemSettings.PmDimm08InfoRef (Read or Write)................................................................................ 242 BIOS.MemSettings.PmDimm09InfoRef (Read or Write)................................................................................ 243 BIOS.MemSettings.PmDimm10InfoRef (Read or Write)................................................................................. 243 BIOS.MemSettings.PmDimm11InfoRef (Read or Write)................................................................
BIOS.MemSettings.PmRegion07InfoRef (Read or Write).............................................................................. 257 BIOS.MemSettings.PmRegion08InfoRef (Read or Write).............................................................................. 258 BIOS.MemSettings.PmRegion09InfoRef (Read or Write).............................................................................. 258 BIOS.MemSettings.PmRegion10InfoRef (Read or Write)...............................................................
BIOS.MemSettings.RemainingRatedWriteEndurance7 (Read or Write)..................................................... 269 BIOS.MemSettings.RemainingRatedWriteEndurance8 (Read or Write)..................................................... 269 BIOS.MemSettings.RemainingRatedWriteEndurance9 (Read or Write)..................................................... 270 BIOS.MemSettings.RemainingRatedWriteEndurance10 (Read or Write)....................................................270 BIOS.MemSettings.
BIOS.MemSettings.SecureErase09 (Read or Write)....................................................................................... 282 BIOS.MemSettings.SecureErase10 (Read or Write)........................................................................................ 283 BIOS.MemSettings.SecureErase11 (Read or Write)......................................................................................... 283 BIOS.MemSettings.SecureErase12 (Read or Write).................................................
BIOS.MemSettings.SpeedMHz05 (Read or Write).......................................................................................... 294 BIOS.MemSettings.SpeedMHz06 (Read or Write).......................................................................................... 294 BIOS.MemSettings.SpeedMHz07 (Read or Write).......................................................................................... 294 BIOS.MemSettings.SpeedMHz08 (Read or Write).......................................................
BIOS.NetworkSettings.IscsiDev1EnDis (Read or Write)................................................................................. 306 BIOS.NetworkSettings.IscsiInitiatorName (Read or Write)............................................................................306 BIOS.NetworkSettings.PxeDev1EnDis (Read or Write).................................................................................. 306 BIOS.NetworkSettings.PxeDev2EnDis (Read or Write).......................................................
BIOS.ProcSettings.L2UpDownPrefetcher (Read or Write)............................................................................ 319 BIOS.ProcSettings.LmceEn (Read or Write)...................................................................................................... 319 BIOS.ProcSettings.LogicalProc (Read or Write)............................................................................................... 319 BIOS.ProcSettings.MadtCoreEnumeration (Read or Write)..................................
BIOS.ProcSettings.ProcBusSpeed (Read or Write)......................................................................................... 333 BIOS.ProcSettings.ProcCcds (Read or Write).................................................................................................. 333 BIOS.ProcSettings.ProcConfigTdp (Read or Write)........................................................................................ 333 BIOS.ProcSettings.ProcCores (Read or Write)............................................
BIOS.PxeDev4Settings.PxeDev4Protocol (Read or Write)............................................................................ 345 BIOS.PxeDev4Settings.PxeDev4VlanEnDis (Read or Write)......................................................................... 345 BIOS.PxeDev4Settings.PxeDev4VlanId (Read or Write)................................................................................ 346 BIOS.PxeDev4Settings.PxeDev4VlanPriority (Read or Write).........................................................
BIOS.SataSettings.SataPortIModel (Read or Write)....................................................................................... 358 BIOS.SataSettings.SataPortJ (Read or Write)..................................................................................................359 BIOS.SataSettings.SataPortJCapacity (Read or Write)................................................................................. 359 BIOS.SataSettings.SataPortJDriveType (Read or Write)......................................
BIOS.SlotDisablement.Slot1 (Read or Write)......................................................................................................374 BIOS.SlotDisablement.Slot2 (Read or Write)..................................................................................................... 374 BIOS.SlotDisablement.Slot3 (Read or Write).....................................................................................................375 BIOS.SlotDisablement.Slot4 (Read or Write)...........................
BIOS.SysProfileSettings.Proc3TurboCoreNum (Read or Write).................................................................. 390 BIOS.SysProfileSettings.Proc4TurboCoreNum (Read or Write)................................................................... 391 BIOS.SysProfileSettings.ProcC1E (Read or Write)........................................................................................... 391 BIOS.SysProfileSettings.ProcCStates (Read or Write).............................................................
BIOS.SysSecurity.TpmSecurity (Read or Write)...............................................................................................405 BIOS.SysSecurity.TpmStatus (Read or Write).................................................................................................. 406 BIOS.SysSecurity.UefiVariableAccess (Read or Write)...................................................................................406 BIOS.TpmAdvancedSettings..............................................................
FC.HBAConfig.EighthNVMeTargetWWNN (Read or Write)...........................................................................418 FC.HBAConfig.EighthNVMeTargetWWPN (Read or Write)........................................................................... 418 FC.HBAConfig.EighthNVMeTgtCntlrID (Read or Write)................................................................................. 418 FC.HBAConfig.EighthNVMeTgtConn (Read or Write)..........................................................................
FC.HBAConfig.SixthNVMeTargetWWPN (Read or Write).............................................................................429 FC.HBAConfig.SixthNVMeTgtCntlrID (Read or Write)................................................................................... 429 FC.HBAConfig.SixthNVMeTgtConn (Read or Write)...................................................................................... 430 FC.HBAConfig.SixthNVMeTgtNSID (Read or Write)..................................................................
iDRAC.ADGroup.Domain (Read or Write)........................................................................................................... 443 iDRAC.ADGroup.Name (Read or Write).............................................................................................................. 443 iDRAC.ADGroup.Privilege (Read or Write)......................................................................................................... 443 iDRAC.APSTable....................................................
iDRAC.CurrentIPv6.Address15 (Read Only)....................................................................................................... 454 iDRAC.CurrentIPv6.Address2 (Read Only).........................................................................................................454 iDRAC.CurrentIPv6.Address3 (Read Only).........................................................................................................454 iDRAC.CurrentIPv6.Address4 (Read Only).................................
iDRAC.CurrentNIC.NICInterface3NCSIPortStart (Read or Write)...............................................................465 iDRAC.CurrentNIC.NumberOfLOM (Read Only)...............................................................................................466 iDRAC.CurrentNIC.PendingActiveNIC (Read or Write)...................................................................................466 iDRAC.CurrentNIC.PingEnable (Read Only)........................................................................
iDRAC.DelegatedAuthConfig.AuthServerConnectTimeout (Read or Write).............................................. 476 iDRAC.DelegatedAuthConfig.AuthServerTransferTimeout (Read or Write).............................................. 477 iDRAC.DelegatedAuthConfig.JwkCacheTime (Read or Write)...................................................................... 477 iDRAC.DelegatedAuthConfig.TokenTimeSlack (Read or Write).................................................................... 477 iDRAC.EmailAlert...
iDRAC.GroupManager.GroupingTimestamp (Read Only)................................................................................487 iDRAC.GroupManager.GroupingUser (Read Only)........................................................................................... 488 iDRAC.GroupManager.GroupName (Read Only)...............................................................................................488 iDRAC.GroupManager.GroupPasscode (Read or Write)......................................................
iDRAC.Info.Type (Read Only)................................................................................................................................ 499 iDRAC.Info.Version (Read Only)............................................................................................................................499 iDRAC.IntegratedDatacenter....................................................................................................................................... 499 iDRAC.IntegratedDatacenter.
iDRAC.IPMIIPConfig.BackupGatewayIP (Read or Write)................................................................................ 510 iDRAC.IPMIIPConfig.BackupGatewayMac (Read or Write)............................................................................510 iDRAC.IPMIIPConfig.DefaultGatewayMAC (Read or Write)...........................................................................510 iDRAC.IPMIIPConfig.IPHeader (Read or Write)........................................................................
iDRAC.IPMISerial.SessionTerminalTimeout (Read or Write)...........................................................................521 iDRAC.IPMISerial.SessionTimeout (Read or Write)...........................................................................................521 iDRAC.IPMISystemParameter.ControllerIPMBAddress (Read or Write).................................................... 522 iDRAC.IPMISystemParameter.DeviceGUID (Read or Write)................................................................
iDRAC.IPv6.Address5 (Read Only).......................................................................................................................532 iDRAC.IPv6.Address6 (Read Only).......................................................................................................................532 iDRAC.IPv6.Address7 (Read Only)....................................................................................................................... 532 iDRAC.IPv6.Address8 (Read Only)..................
iDRAC.KMS.ProxyPortNumber (Read or Write)............................................................................................... 543 iDRAC.KMS.ProxyUsername (Read or Write)................................................................................................... 543 iDRAC.KMS.RedundantKMIPPortNumber (Read or Write)........................................................................... 543 iDRAC.KMS.RedundantServerAddress1 (Read or Write)..................................................
iDRAC.Logging.SELBufferType (Read or Write)...............................................................................................553 iDRAC.Logging.SELOEMEventFilterEnable (Read or Write)......................................................................... 554 iDRAC.Logging.SetSELTimeBlock (Read or Write).......................................................................................... 554 iDRAC.MgmtNetworkInterface.........................................................................
iDRAC.NIC.MACAddress (Read Only)................................................................................................................. 565 iDRAC.NIC.maxlomsupported (Read Only)........................................................................................................ 565 iDRAC.NIC.MezzPwrState (Read Only)..............................................................................................................565 iDRAC.NIC.ModularLinkstatus (Read or Write).........................
iDRAC.OCPInformation.PCISSID (Read or Write)............................................................................................ 576 iDRAC.OCPInformation.PCISVID (Read or Write)............................................................................................ 577 iDRAC.OCPInformation.PCIVendorID (Read or Write).................................................................................... 577 iDRAC.OCPInformation.ThresholdTemp (Read or Write)...........................................
iDRAC.PlatformCapability.NGMPlatform (Read Only).................................................................................... 588 iDRAC.PlatformCapability.NicVLANCapable (Read Only).............................................................................. 588 iDRAC.PlatformCapability.NMCapable (Read or Write)..................................................................................588 iDRAC.PlatformCapability.NMPTASCapable (Read Only).......................................................
iDRAC.PMLicensing.LM-BASE-IPMI-GUI (Read or Write).............................................................................600 iDRAC.PMLicensing.LM-BASIC-REMOTE-INVENTORY-EXPORT (Read or Write).................................601 iDRAC.PMLicensing.LM-BMC-PLUS (Read or Write)..................................................................................... 601 iDRAC.PMLicensing.LM-BOOT-CAPTURE (Read or Write)...........................................................................601 iDRAC.
iDRAC.PMLicensing.LM-SFPOpticalMonitoring (Read or Write).................................................................. 613 iDRAC.PMLicensing.LM-Simple-2FA (Read or Write)......................................................................................614 iDRAC.PMLicensing.LM-SmartLogs (Read or Write)....................................................................................... 614 iDRAC.PMLicensing.LM-SMASH-CLP (Read or Write)...............................................................
iDRAC.PrivateStore.BladePreBudgetMax (Read or Write)............................................................................ 625 iDRAC.PrivateStore.BladePreBudgetMin (Read or Write)............................................................................. 626 iDRAC.PrivateStore.BladeSeamlessMethod (Read or Write)........................................................................ 626 iDRAC.PrivateStore.BladeStorNormalPwr (Read or Write).............................................................
iDRAC.RFS.IgnoreCertWarning (Read or Write)...............................................................................................636 iDRAC.RFS.Image (Read or Write)....................................................................................................................... 636 iDRAC.RFS.MediaAttachState (Read Only)....................................................................................................... 637 iDRAC.RFS.Password (Read or Write)...................................
iDRAC.SecondaryNIC.VLANPriority (Read or Write)....................................................................................... 647 iDRAC.SecureDefaultPassword...................................................................................................................................648 iDRAC.SecureDefaultPassword.AESiv (Read Only)......................................................................................... 648 iDRAC.SecureDefaultPassword.AESKey (Read Only)..........................
iDRAC.SecurityCertificate.IssuerCountryCode (Read Only)..........................................................................659 iDRAC.SecurityCertificate.IssuerLocality (Read Only).................................................................................... 659 iDRAC.SecurityCertificate.IssuerOrganization (Read Only)...........................................................................659 iDRAC.SecurityCertificate.IssuerOrganizationalUnit (Read Only).........................................
iDRAC.SEKMCert.iDRACCertSharePassword (Read or Write).....................................................................670 iDRAC.SEKMCert.iDRACCertShareProxyAddress (Read or Write).............................................................. 671 iDRAC.SEKMCert.iDRACCertShareProxyPassword (Read or Write)........................................................... 671 iDRAC.SEKMCert.iDRACCertShareProxyPort (Read or Write)..................................................................... 671 iDRAC.
iDRAC.ServerBoot.BootOptionWatchdog (Read or Write)............................................................................ 682 iDRAC.ServerBoot.FirstBootDevice (Read or Write).......................................................................................682 iDRAC.ServerBoot.VflashBootPartition (Read or Write)................................................................................ 682 iDRAC.ServerInfo.SubsystemPrefix (Read Only)............................................................
iDRAC.SNMPTrapIPv6.DestIPv6Addr (Read or Write)...................................................................................693 iDRAC.SNMPTrapIPv6.State (Read or Write)...................................................................................................693 iDRAC.SSH....................................................................................................................................................................... 693 iDRAC.SSH.Banner (Read or Write)......................
iDRAC.SupportAssist.ShippingInfoCity (Read or Write)................................................................................. 704 iDRAC.SupportAssist.ShippingInfoCompanyName (Read or Write)............................................................ 705 iDRAC.SupportAssist.ShippingInfoCountry (Read or Write)..........................................................................705 iDRAC.SupportAssist.ShippingInfoState (Read or Write)................................................................
iDRAC.SysLog.Port (Read or Write)..................................................................................................................... 715 iDRAC.SysLog.PowerLogEnable (Read or Write).............................................................................................. 716 iDRAC.SysLog.PowerLogInterval (Read or Write)............................................................................................ 716 iDRAC.SysLog.Server1 (Read or Write).....................................
iDRAC.TelemetryCPUInventory.IsGroupInstanceValid (Read Only).............................................................726 iDRAC.TelemetryCPUInventory.ReportInterval (Read or Write)...................................................................727 iDRAC.TelemetryCPUInventory.ReportTriggers (Read or Write)................................................................. 727 iDRAC.TelemetryCPUInventory.RsyslogTarget (Read or Write)...................................................................
iDRAC.TelemetryFCInventory.DevicePollFrequency (Read Only).................................................................737 iDRAC.TelemetryFCInventory.EnableTelemetry (Read or Write)..................................................................737 iDRAC.TelemetryFCInventory.FQDD (Read Only)............................................................................................ 737 iDRAC.TelemetryFCInventory.IsGroupInstanceValid (Read Only)..........................................................
iDRAC.TelemetryGPUMetrics.FQDD (Read Only)............................................................................................ 748 iDRAC.TelemetryGPUMetrics.IsGroupInstanceValid (Read Only)................................................................ 748 iDRAC.TelemetryGPUMetrics.ReportInterval (Read or Write)......................................................................748 iDRAC.TelemetryGPUMetrics.ReportTriggers (Read or Write)............................................................
iDRAC.TelemetryMemorySensor.RsyslogTarget (Read or Write)................................................................ 758 iDRAC.TelemetryNICConfig......................................................................................................................................... 759 iDRAC.TelemetryNICConfig.DevicePollFrequency (Read Only)....................................................................759 iDRAC.TelemetryNICConfig.EnableTelemetry (Read or Write)....................................
iDRAC.TelemetryPCIDeviceInventory.EnableTelemetry (Read or Write)................................................... 769 iDRAC.TelemetryPCIDeviceInventory.IsGroupInstanceValid (Read Only).................................................. 769 iDRAC.TelemetryPCIDeviceInventory.ReportInterval (Read or Write)........................................................ 770 iDRAC.TelemetryPCIDeviceInventory.ReportTriggers (Read or Write).......................................................770 iDRAC.
iDRAC.TelemetryPSUMetrics.ReportInterval (Read or Write)...................................................................... 780 iDRAC.TelemetryPSUMetrics.ReportTriggers (Read or Write).....................................................................780 iDRAC.TelemetryPSUMetrics.RsyslogTarget (Read or Write)....................................................................... 781 iDRAC.TelemetrySensor....................................................................................................
iDRAC.TelemetryStoragePCIeSSD.RsyslogTarget (Read or Write)..............................................................791 iDRAC.TelemetryStoragePhysicalDisk........................................................................................................................ 791 iDRAC.TelemetryStoragePhysicalDisk.DevicePollFrequency (Read Only)..................................................792 iDRAC.TelemetryStoragePhysicalDisk.EnableTelemetry (Read or Write)..........................................
iDRAC.TelemetryThermalSensor.DevicePollFrequency (Read Only)........................................................... 802 iDRAC.TelemetryThermalSensor.EnableTelemetry (Read or Write)............................................................ 802 iDRAC.TelemetryThermalSensor.FQDD (Read Only).......................................................................................803 iDRAC.TelemetryThermalSensor.IsGroupInstanceValid (Read Only)...........................................................
iDRAC.Users.EmailAddress (Read or Write)....................................................................................................... 813 iDRAC.Users.Enable (Read or Write)....................................................................................................................813 iDRAC.Users.ETAG (Read Only)............................................................................................................................ 813 iDRAC.Users.IPMIKey (Read or Write)..................
iDRAC.VirtualConsole.ActiveSessions (Read Only).......................................................................................... 824 iDRAC.VirtualConsole.AttachState (Read or Write)........................................................................................ 824 iDRAC.VirtualConsole.BootCaptureFileCount (Read or Write)..................................................................... 825 iDRAC.VirtualConsole.BootCaptureFileName (Read Only)..............................................
iDRAC.VNCServer.ActiveSessions (Read Only)................................................................................................836 iDRAC.VNCServer.Enable (Read or Write)........................................................................................................ 836 iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write)...................................................................836 iDRAC.VNCServer.MaxSessions (Read or Write).....................................................
InfiniBand.FirmImgMenu.EFIVersion (Read Only)............................................................................................. 848 InfiniBand.FirmImgMenu.FamilyVersion (Read Only)....................................................................................... 848 InfiniBand.IscsiFirstTgtParams.................................................................................................................................... 848 InfiniBand.IscsiFirstTgtParams.
InfiniBand.VndrConfigPage.MacAddr (Read only)............................................................................................859 InfiniBand.VndrConfigPage.NetworkLinkType (Read or Write).................................................................... 859 InfiniBand.VndrConfigPage.NicMode (Read or Write).................................................................................... 860 InfiniBand.VndrConfigPage.NicPartitioningSupport (Read Only)...........................................
LifecycleController.OSD.ExposeDuration (Read Only).................................................................................... 872 LifecycleController.OSD.OSMediaHashType (Read Only).............................................................................. 872 LifecycleController.OSD.OSMediaHashValue (Read Only)............................................................................. 872 LifecycleController.OSD.OSMediaName (Read Only)..........................................................
NIC.DCBSettings.EnhancedTransmissionSelection (Read Only).................................................................. 885 NIC.DCBSettings.LocalDCBXWillingMode (Read or Write)........................................................................... 886 NIC.DCBSettings.PriorityFlowControl (Read Only)..........................................................................................886 NIC.DCBSettings.PriorityGroup0BandwidthAllocation (Read or Write)..............................................
NIC.FCOECapabilities.MaxNumberExchanges (Read Only)...........................................................................899 NIC.FCOECapabilities.MaxNumberLogins (Read Only)...................................................................................899 NIC.FCOECapabilities.MaxNumberOfFCTargets (Read Only)...................................................................... 900 NIC.FCOECapabilities.MaxNumberOutStandingCommands (Read Only)..................................................
NIC.IscsiFirstTgtParams.FirstTgtTcpPort (Read or Write).............................................................................910 NIC.IscsiGenParams........................................................................................................................................................910 NIC.IscsiGenParams.ChapAuthEnable (Read or Write).................................................................................... 911 NIC.IscsiGenParams.ChapMutualAuth (Read or Write)...............
NIC.LnkSpeedConfig.100Gbps2 (Read or Write)...............................................................................................921 NIC.LnkSpeedConfig.100Gbps4 (Read or Write)..............................................................................................922 NIC.LnkSpeedConfig.100Mbps (Read or Write)............................................................................................... 922 NIC.LnkSpeedConfig.10Gbps (Read or Write)..............................................
NIC.VndrConfigPage.BusDeviceFunction (Read Only)................................................................................... 936 NIC.VndrConfigPage.ChipMdl (Read Only)........................................................................................................936 NIC.VndrConfigPage.DCBSettings (Read Only)............................................................................................... 936 NIC.VndrConfigPage.DCBSettingsRef (Read Only)...........................................
NIC.VndrConfigPage.PortGUID (Read Only)..................................................................................................... 948 NIC.VndrConfigPage.PXEBootSupport (Read Only)....................................................................................... 948 NIC.VndrConfigPage.RDMANICModeOnPort (Read or Write)..................................................................... 949 NIC.VndrConfigPage.RemotePHY (Read Only)................................................................
PSU.Info.Redundancy (Read Only)............................................................................................................................ 962 PSU.Info.SerialNumber (Read Only).......................................................................................................................... 962 PSU.Info.State (Read Only).........................................................................................................................................
Storage.Enclosure.Enclousre Requested Configuration Mode (Read or Write)........................................975 Storage.PhysicalDisk...................................................................................................................................................... 975 Storage.Physical Disk.Bus Protocol (Read Only).............................................................................................. 975 Storage.Physical Disk.Certified (Read or Write).............................
System.ChassisInfo ....................................................................................................................................................... 987 System.ChassisInfo.ChassisBoardPartNumber (Read Only)..........................................................................987 System.ChassisInfo.ChassisBoardSerialNumber (Read Only)........................................................................987 System.ChassisInfo.ChassisModel (Read Only)................................
System.LeaseInfo.MultiSched (Read or Write)................................................................................................. 998 System.LeaseInfo.RateFactor (Read or Write)................................................................................................. 998 System.MaintenanceInfo.............................................................................................................................................. 998 System.MaintenanceInfo.EndDate (Read or Write).......
System.ServerInfo.RChassisServiceTag (Read Only)....................................................................................1008 System.ServerInfo.ServerType (Read Only).................................................................................................... 1008 System.ServerInfo.ServiceTag (Read Only).....................................................................................................1009 System.ServerOS....................................................................
System.Storage.RemainingRatedWriteEnduranceAlertThreshold (Read or Write)................................. 1019 System.SupportInfo.......................................................................................................................................................1019 System.SupportInfo.AutoFix (Read or Write)...................................................................................................1019 System.SupportInfo.HelpDesk (Read or Write).....................................
System.WarrantyInfo.................................................................................................................................................... 1031 System.WarrantyInfo.Cost (Read or Write)...................................................................................................... 1031 System.WarrantyInfo.Duration (Read or Write)............................................................................................... 1031 System.WarrantyInfo.EndDate (Read or Write)...
1 iDRAC Property Database Group and Object Descriptions The iDRAC property database contains the configuration information for iDRAC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this guide. To configure iDRAC, use the group and object IDs. All string values are limited to displayable ASCII characters, except where otherwise noted.
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 84 Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added Added support support support support support support support support support support support support support support support support support support support support for for for for for for for for for for for for for for for for for for for for iDRAC.TelemetryiDRACLogs group. iDRAC.TelemetryLCLog group. iDRAC.TelemetryMemoryConfig group. iDRAC.
2 BIOS Attributes This section provides details about the BIOS attribute groups and objects. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • BIOS.BiosBootSettings BIOS.BootSeqEnDis BIOS.DebugMenuIioConfigurationSettings BIOS.DebugMenuSetting BIOS.EmbServerMgmt BIOS.HttpDev1Settings BIOS.HttpDev2Settings BIOS.HttpDev3Settings BIOS.HttpDev4Settings BIOS.HttpDev1TlsConfig BIOS.HttpDev2TlsConfig BIOS.HttpDev3TlsConfig BIOS.HttpDev4TlsConfig BIOS.IntegratedDevices BIOS.
BIOS.BiosBootSettings.BiosBootSeq (Read or Write) Description This field tells the system where to find the operating system files needed for system startup. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.
BIOS.BiosBootSettings.BootSeqEnDis2 (Read or Write) Description This field enables or disables this boot option in the Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'. Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.BootSeqEnDis6 (Read or Write) Description This field enables or disables this boot option in the Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'.
Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.BootSeqEnDis10 (Read or Write) Description This field enables or disables this boot option in the Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'.
BIOS.BiosBootSettings.BootSeqEnDis13 (Read or Write) Description This field enables or disables this boot option in the Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'. Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.BootSeqEnDis17 (Read or Write) Description This field enables or disables this boot option in the Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'BIOS'; it has no effect when Boot Mode is 'UEFI'.
Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.BootSeqEnDisRef (Read or Write) Description Legal Values ● BootSeqEnDis Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BiosBootSettings.
BIOS.BootSettings.BootSeqRetry (Read or Write) Description This field enables or disables the Boot Sequence Retry feature or resets the system. If the last attempt to boot has failed, the system immediately performs a cold reset or retries to boot after a 30 second time-out period, depending on if this field is set to Reset or Enabled.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.OneTimeBootRef (Read or Write) Description This field supports a one-time boot to a specified device. Legal Values ● OneTimeBoot Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
Dependency Not applicable BIOS.BootSettings.SetBootOrderFqdd2 (Read or Write) Description The SetBootOrderFqdd fields specify a list of Fqdds representing the boot list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetBootOrderFqdd6 (Read or Write) Description The SetBootOrderFqdd fields specify a list of Fqdds representing the boot list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetBootOrderFqdd10 (Read or Write) Description The SetBootOrderFqdd fields specify a list of Fqdds representing the boot list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetBootOrderFqdd14 (Read or Write) Description The SetBootOrderFqdd fields specify a list of Fqdds representing the boot list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetLegacyHddOrderFqdd2 (Read or Write) Description The SetLegacyHddOrderFqdd fields specify a list of Fqdds representing the Legacy HDD list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetLegacyHddOrderFqdd6 (Read or Write) Description The SetLegacyHddOrderFqdd fields specify a list of Fqdds representing the Legacy HDD list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetLegacyHddOrderFqdd10 (Read or Write) Description The SetLegacyHddOrderFqdd fields specify a list of Fqdds representing the Legacy HDD list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.SetLegacyHddOrderFqdd14 (Read or Write) Description The SetLegacyHddOrderFqdd fields specify a list of Fqdds representing the Legacy HDD list to be applied on the next boot. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
BIOS.BootSettings.BiosBootSettingsRef (Read or Write) Description This field controls system boot settings when Boot Mode is set to 'BIOS'. This field has no effect when Boot Mode is set to 'UEFI'. Legal Values ● BiosBootSettings Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.BootSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuIioConfigurationSettings This group contains the attributes that provides details about BIOS.DebugMenuIioConfigurationSettings. BIOS.DebugMenuIioConfigurationSettings.DeviceUnhide (Read or Write) Description This field enables/disables IIO Misc Device unhiding. This field also controls powering down unused ports.
BIOS.DebugMenuIioConfigurationSettings.TXEQWA (Read or Write) Description Enable/Disable PCIe TXEQ Workaround. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuIioConfigurationSettings.UnusedPcieClk (Read or Write) Description This field enables unused PCIe clocks for Mfg Test. When Enabled, no attempt is made to disable PCIe clocks.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.BiosCpuKnobTuning (Read or Write) Description BIOS CPU Knob Tuning Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.BrowserOptionsRef (Read or Write) Description HII forms browser options Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.CEWarningThresholdDebugMenu (Read or Write) Description Set the Correctable Error Warning Threshold. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.CurrentLimit (Read or Write) Description Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.DciTransport (Read or Write) Description Enabling this field will turn on the Intel PCH Direct Connect Interface.
BIOS.DebugMenuSetting.DebugErrorLevel (Read or Write) Description This field controls serial DEBUG output level for certain drivers. The value overrides the platform PcdDebugPrintErrorLevel PCD value.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.EmbSataTestMode (Read or Write) Description Enable Test Mode for SATA ports of the embedded SATA controllers. Is located in Debug Menu, which is hidden after RTS. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.IntelTestEventIio (Read or Write) Description Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.InteractivePassword24A (Read or Write) Description Enables or disables the new flow of interactive password defined since UEFI 2.4A (1085 and 1174 errata).
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.LinkDowntrainReporting (Read or Write) Description Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.LlcPrefetch (Read or Write) Description "Enable/Disable LLC Prefetch on all threads.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.MeEopEnable (Read or Write) Description Changing this field will enable/disable the ME EOP message Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.MemoryFastBootCold (Read or Write) Description Enable/Disable Memory RMT. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.MemoryMultiThread (Read or Write) Description Enable/Disable Memory RMT.
Dependency Not applicable BIOS.DebugMenuSetting.MemoryThrottlingMode (Read or Write) Description Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control MemoryThrottlingModeOLTT MemoryThrottlingModeCLTT MemoryThrottlingModeCLTTWithPECI MemoryThrottlingModeNone License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
Dependency Not applicable BIOS.DebugMenuSetting.MultiThreaded (Read or Write) Description Enable to execute the Memory Reference Code multi-threaded. Legal Values ● Auto ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
BIOS.DebugMenuSetting.PostPackageRepair (Read or Write) Description Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control HardPPR SoftPPR SystemPPR Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
BIOS.DebugMenuSetting.PSPConsoleOut (Read or Write) Description This field enables/disables PSP Console Output (serial debug). Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.RankMargin (Read or Write) Description Enable/Disable Memory RMT.
BIOS.DebugMenuSetting.RebootTestPoint (Read or Write) Description This field selects Reboot Location. Legal Values ● RebootTestPointMemInit ● RebootTestPointPciInit Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.S4Support (Read or Write) Description Enable, Disable, or allow normal platform control (Auto) of S4 Sleep State Support.
BIOS.DebugMenuSetting.TpmBindingReset (Read or Write) Description Clears the TPM, resets the binding and turns off TPM Security. To apply this, TPM Security should also be set to On when setting TPM Binding Reset to On. Legal Values ● Yes ● No Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.DebugMenuSetting.
BIOS.EmbServerMgmt This group contains the attributes that provides details about BIOS.EmbServerMgmt. BIOS.EmbServerMgmt.EmbServerMgmt (Read or Write) Description Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.EmbServerMgmt.
BIOS.HttpDev1Settings.HttpDev1DhcpEnDis (Read or Write) Description DHCP Enable/Disable for this HTTP Device. When the protocol is set to IPv6, this field is forced to Enabled. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.HttpDev1Dns1 (Read or Write) Description Primary DNS server IP address for this HTTP Device.
BIOS.HttpDev1Settings.HttpDev1Gateway (Read or Write) Description Gateway for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.
● IPv6 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.HttpDev1Settings (Read or Write) Description This field controls the configuration for this HTTP device Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.HttpDev1VlanId (Read or Write) Description When VLAN is enabled, identifies which of the 4094 possible VLANs contains the desired DNS or HTTP servers. This value can be from 1 to 4094 inclusive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev1Settings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev2Settings.HttpDev2Dns2 (Read or Write) Description Secondary DNS server IP address for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Dependency Not applicable BIOS.HttpDev2Settings.HttpDev2Ip (Read or Write) Description IP address for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev2Settings.HttpDev2Mask (Read or Write) Description Subnet mask for this HTTP Device.
BIOS.HttpDev2Settings.HttpDev2TlsConfigRef (Read or Write) Description View and/or modify this device's authetication configuration. ? Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev2Settings.HttpDev2Uri (Read or Write) Description Contains the Uniform Resource Identifier (URI) that the BIOS should boot.
BIOS.HttpDev2Settings.HttpDev2VlanPriority (Read or Write) Description When VLAN is enabled, identifies which of 8 possible priorities are assigned to the VLAN having the given ID. This value can be from 0 to 7 inclusive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev2Settings.
Dependency Not applicable BIOS.HttpDev3Settings.HttpDev3Dns2 (Read or Write) Description Secondary DNS server IP address for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev3Settings.
BIOS.HttpDev3Settings.HttpDev3Ip (Read or Write) Description IP address for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev3Settings.HttpDev3Mask (Read or Write) Description Subnet mask for this HTTP Device.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev3Settings.HttpDev3Uri (Read or Write) Description Contains the Uniform Resource Identifier (URI) that the BIOS should boot. If this field is blank, the BIOS will attempt to contact the network's DHCP server and ask it for the boot file name.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev4Settings This group contains the attributes that provides details about BIOS.HttpDev4Settings. BIOS.HttpDev4Settings.HttpDev4DhcpEnDis (Read or Write) Description DHCP Enable/Disable for this HTTP Device. When the protocol is set to IPv6, this field is forced to Enabled.
Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev4Settings.HttpDev4Gateway (Read or Write) Description Gateway for this HTTP Device. When the protocol is set to IPv6, this field is configured automatically.
Dependency Not applicable BIOS.HttpDev4Settings.HttpDev4Protocol (Read or Write) Description Determines whether Internet Protocol version 4 (the most common, older version) or Internet Protocol version 6 (the newest version) is used for this device. Legal Values ● IPv4 ● IPv6 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev4Settings.
BIOS.HttpDev4Settings.HttpDev4VlanEnDis (Read or Write) Description Set this field to Enabled if your DNS or HTTP servers reside on a Virtual LAN (VLAN). Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev4Settings.HttpDev4VlanId (Read or Write) Description When VLAN is enabled, identifies which of the 4094 possible VLANs contains the desired DNS or HTTP servers.
BIOS.HttpDev1TlsConfig.HttpDev1TlsMode (Read or Write) Description This field is to set the authetication mode for this HTTP device. bios.networkSettings.HttpDev1EnDis Legal Values ● "None", "OneWay" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev2TlsConfig This group contains the attributes that provides details about BIOS.HttpDev2TlsConfig. BIOS.HttpDev2TlsConfig.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.HttpDev3TlsConfig.HttpDev3TlsMode (Read or Write) Description This field is to set the authetication mode for this HTTP device. bios.networkSettings.HttpDev3EnDis Legal Values ● "None", "OneWay" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
BIOS.IntegratedDevices.CurrentEmbVideoState (Read or Write) Description Read-only. Indicates the current state of the Embedded Video Controller. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is Disabled.
Legal Values ● Enabled ● DisabledOs ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.EmbNic2 (Read or Write) Description Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Enabled EnabledPxe EnablediScsi Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.
BIOS.IntegratedDevices.EmbNic4 (Read or Write) Description Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Enabled EnabledPxe EnablediScsi Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.EmbNicPort1BootProto (Read or Write) Description This is a Write-Only attribute to control the Legacy Boot Protocol of the LOM Port specified by the Embedded NIC port number.
BIOS.IntegratedDevices.EmbNicPort3BootProto (Read or Write) Description This is a Write-Only attribute to control the Legacy Boot Protocol of the LOM Port specified by the Embedded NIC port number. This attribute is for system management software use, and does not appear in System BIOS Setup. This attribute always returns Unknown when read. There is no change to the LOM Port Legacy Boot Protocol setting when Unknown is written.
BIOS.IntegratedDevices.GlobalSlotDriverDisable (Read or Write) Description If you set this field to Enabled, the BIOS will not load any legacy option ROMs (when Boot Mode is BIOS) or UEFI drivers (when Boot Mode is UEFI) for any cards in the system slots. If the boot support for some card is provided by the option ROM, then the system will not be able to boot from the card, nor will its pre-boot services be available. However, the card will be available for operating system use.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.IntegratedRaid (Read or Write) Description Enables or disables the integrated RAID controller. When set to Disabled, the device is not visible to the operating system (OS). Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.InternalSdCardPrimaryCard (Read or Write) Description When Redundancy is set to Disabled, either one of the SD card can be selected to present itself as mass storage device by setting it to be primary card. By default primary SD card is selected to be SD Card 1.
BIOS.IntegratedDevices.InternalUsb1 (Read or Write) Description Enables or disables the internal USB port 1. Legal Values ● On ● Off Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.InternalUsb2 (Read or Write) Description Enables or disables the internal USB port 2.
● Pxe ● Iscsi Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.IntNic1Port3BootProto (Read or Write) Description This is a Write-Only attribute to control the Legacy Boot Protocol of the LOM Port specified by the Integrated Network Card number and port number. This attribute is for system management software use, and does not appear in System BIOS Setup.
● None ● Pxe ● Iscsi Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.IntNic2Port2BootProto (Read or Write) Description This is a Write-Only attribute to control the Legacy Boot Protocol of the LOM Port specified by the Integrated Network Card number and port number. This attribute is for system management software use, and does not appear in System BIOS Setup.
Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown None Pxe Iscsi License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.IoatEngine (Read or Write) Description Enables or disables the I/O Acceleration Technology (I/OAT). I/OAT is a set of DMA features designed to accelerate network traffic and lower CPU utilization. This feature should be enabled only if the hardware and software support I/OAT.
Dependency Not applicable BIOS.IntegratedDevices.MmioAbove4Gb (Read or Write) Description Enables support for PCIe devices that require large amount of MMIO resources. Enable this option only for 64-bit operating systems. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.
This Attribute allows more granularity in controlling (Enabling/Disabling) NDC. This attribute is only displayed and used when NdcPcieLinkControl internal attribute default value is set to "Individual".This is most likey done in a PM (OEM ID). Legal Values ● Enabled ● DisabledOs Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.
Only available on R7920. Controlled by DPI feature: FeatureSupport.PcieBusCustomizable Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control PcieBusUniform PcieBusCustomOpt1 PcieBusCustomOpt2 PcieBusCustomOpt3 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.
BIOS.IntegratedDevices.PciePreferredIoDeviceBus (Read or Write) Description This field sets the PCI bus address that preferred IO device resides. Bus address ranges from [0x0:0xFF]. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.PciePreferredIoDeviceDev (Read or Write) Description This field sets the PCI device address that preferred IO device resides.
Legal Values ● RipsPresenceYes ● RipsPresenceNo Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IntegratedDevices.SlotDisablementRef (Read or Write) Description Controls the configuration of PCIe cards installed in the specified slot. Only slots that are present on the system will be available for control.
BIOS.IntegratedDevices.Usb3Setting (Read or Write) Description Controls USB 3.0 support. When set to Disabled, BIOS disables USB 3.0 mode for all the USB3.0 ports. The USB devices operate at USB2.0 mode. When set to Enabled, BIOS operates all USB3.0 ports at USB2.0 mode during POST, and switches them to USB3.0 mode right after the operating system (OS) boots. You must select this option only if the operating system (such as. Windows Server 2012) has a native USB 3.0 driver.
Ports On and All Ports Off will disable the USB management port and restrict access to the iDRAC USB management port features. Blades do not support setting the Attribute UsbPorts to the value OnlyBackPortsOn. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control AllOn OnlyBackPortsOn AllOff AllOffDynamic License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.IscsiDev1Con1ChapType (Read or Write) Description CHAP type for this iSCSI connection. Legal Values ● OneWay ● Mutual Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.IscsiDev1Con1Ip (Read or Write) Description Initiator IP Address for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.IscsiDev1Con1Port (Read or Write) Description Target Port for this iSCSI connection. The standard port number for iSCSI connections is 3260. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.
BIOS.IscsiDev1Con1Settings.IscsiDev1Con1RevChapSecret (Read or Write) Description Reverse CHAP secret for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.
BIOS.IscsiDev1Con1Settings.IscsiDev1Con1TgtDhcpEnDis (Read or Write) Description Target DHCP Enable/Disable for this iSCSI connection. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con1Settings.IscsiDev1Con1Timeout (Read or Write) Description Timeout for this iSCSI connection in milliseconds.
BIOS.IscsiDev1Con1Settings.IscsiDev1Con1VlanPriority (Read or Write) Description VLAN priority for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings This group contains the attributes that provides details about BIOS.IscsiDev1Con2Settings. BIOS.IscsiDev1Con2Settings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2ChapType (Read or Write) Description CHAP type for this iSCSI connection. Legal Values ● OneWay ● Mutual Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2DhcpEnDis (Read or Write) Description DHCP Enable/Disable for this iSCSI connection.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2Ip (Read or Write) Description Initiator IP Address for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2IsId (Read or Write) Description ISID for this iSCSI connection.
Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2Port (Read or Write) Description Target Port for this iSCSI connection. The standard port number for iSCSI connections is 3260. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2Protocol (Read or Write) Description This field controls the Internet Protocol used for this iSCSI connection.
BIOS.IscsiDev1Con2Settings.IscsiDev1Con2RevChapSecret (Read or Write) Description Reverse CHAP secret for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.
BIOS.IscsiDev1Con2Settings.IscsiDev1Con2TgtDhcpEnDis (Read or Write) Description Target DHCP Enable/Disable for this iSCSI connection. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDev1Con2Settings.IscsiDev1Con2Timeout (Read or Write) Description Timeout for this iSCSI connection in milliseconds.
BIOS.IscsiDev1Con2Settings.IscsiDev1Con2VlanPriority (Read or Write) Description VLAN priority for this iSCSI connection. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDevice1Settings This group contains the attributes that provides details about BIOS.IscsiDevice1Settings. BIOS.IscsiDevice1Settings.
Dependency Not applicable BIOS.IscsiDevice1Settings.IscsiDev1Con2SettingsRef (Read or Write) Description Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDevice1Settings.IscsiDev1ConOrder (Read or Write) Description This field controls the order for which the iSCSI connections will be attempted.
BIOS.IscsiDevice1Settings.IscsiDev1Con1EnDis (Read or Write) Description This field controls the configuration for this iSCSI connection. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.IscsiDevice1Settings.IscsiDev1Con2EnDis (Read or Write) Description This field controls the configuration for this iSCSI connection.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.AddrBasMir (Read or Write) Description If the system is configured for Dell Fault Resilient Mode (FRM), controls the amount of memory for FRM per processor. The FRM memory is located on a single memory riser per processor. Only half of the FRM memory will be visible to the OS. Has a dependency where DIMM population within the system needs to support Mirror mode.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity00 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity01 (Read or Write) Description The size of this NVDIMM.
BIOS.MemSettings.Capacity04 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity05 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity09 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity10 (Read or Write) Description The size of this NVDIMM.
BIOS.MemSettings.Capacity13 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity14 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity18 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity19 (Read or Write) Description The size of this NVDIMM.
BIOS.MemSettings.Capacity22 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Capacity23 (Read or Write) Description The size of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.CorrEccSmi (Read or Write) Description Allows the system to log ECC corrected DRAM errors into the SEL log. Logging these rare errors can help identify marginal components; however the system will pause for a few milliseconds after an error while the log entry is created. Latency conscious customers may wish to disable the feature. Spare Mode, and Mirror mode require this feature to be enabled.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator00 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.DeviceLocator04 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator05 (Read or Write) Description The DIMM slot that this NVDIMM is being populated.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator09 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator10 (Read or Write) Description The DIMM slot that this NVDIMM is being populated.
BIOS.MemSettings.DeviceLocator13 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator14 (Read or Write) Description The DIMM slot that this NVDIMM is being populated.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator18 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator19 (Read or Write) Description The DIMM slot that this NVDIMM is being populated.
BIOS.MemSettings.DeviceLocator22 (Read or Write) Description The DIMM slot that this NVDIMM is being populated. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DeviceLocator23 (Read or Write) Description The DIMM slot that this NVDIMM is being populated.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot03 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.DimmSlot07 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot08 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot12 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.DimmSlot16 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot17 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot22 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.DimmSlot26 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot27 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.DimmSlot31 (Read or Write) Description "When set to Enabled, the DIMM slot is enabled.n" "When set to Disabled, the DIMM slot is disabled.n" Legal Values ● "Enabled", "Disabled" Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.FirmwareVersion02 (Read or Write) Description The firmware revision of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion03 (Read or Write) Description The firmware revision of this NVDIMM.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion07 (Read or Write) Description The firmware revision of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion08 (Read or Write) Description The firmware revision of this NVDIMM.
BIOS.MemSettings.FirmwareVersion11 (Read or Write) Description The firmware revision of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion12 (Read or Write) Description The firmware revision of this NVDIMM.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion16 (Read or Write) Description The firmware revision of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion17 (Read or Write) Description The firmware revision of this NVDIMM.
BIOS.MemSettings.FirmwareVersion20 (Read or Write) Description The firmware revision of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.FirmwareVersion21 (Read or Write) Description The firmware revision of this NVDIMM.
This option is grayed out(read only) when "Fault Resilient Mode" is not selected in "Memory Operating Mode". This option is only available on Intel platforms. Legal Values ● 25 ● 12.5 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.IntelPersistentMemories (Read or Write) Description View and configure installed Intel Persistent Memories.
BIOS.MemSettings.LockState01 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState04 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState07 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState10 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState13 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState16 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState19 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.LockState22 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown Disabled Unlocked Locked Frozen NotSupported License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.MemOpMode (Read or Write) Description Allows the selection of the memory operating mode. Certain options are active only if a valid memory configuration is detected. When the Optimizer Mode is enabled, the DRAM controllers operate independently in 64-bit mode and provide optimized memory performance. When Advanced ECC Mode is enabled, the two DRAM controllers are combined in 128-bit mode and provide optimized reliability.
BIOS.MemSettings.MemOpVoltage (Read or Write) Description Legal Values ● AutoVolt ● Volt15V Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.MemoryCapacity (Read or Write) Description Total NVDIMM size configured as memory mode in the system.
Dependency Not applicable BIOS.MemSettings.MemoryMapOutRef (Read or Write) Description This field controls DIMMs slots on the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.MemoryTraining (Read or Write) Description Fast - Use previously saved memory training parameters to train the memory subsystem when memory configuration is not changed.
● HardwareBasedTest Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.MemTestType (Read or Write) Description Indicates type of BIOS-based system memory test to perform during POST. When set to Hardware, the memory tests are performed via hardware. When set to Software, the memory tests are performed via software .
BIOS.MemSettings.NativeTrfcTiming (Read or Write) Description Enables 16 Gb density DIMMs to operate at their programmed Row Refresh Cycle Time (tRFC). Enabling this feature may improve system performance for some memory configurations. However, enabling this feature will have no effect on configurations with 16 Gb 3DS/TSV DIMMs.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFactoryDefault0 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFactoryDefault4 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFactoryDefault8 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data.
● NvdimmFactoryDefaultDisable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFactoryDefault12 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data.
Legal Values ● NvdimmFactoryDefaultEnable ● NvdimmFactoryDefaultDisable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFactoryDefault16 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data.
BIOS.MemSettings.NvdimmFactoryDefault19 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data. WARNING: All contents in NVDIMM-N will be lost if changes are saved when exiting BIOS! Legal Values ● NvdimmFactoryDefaultEnable ● NvdimmFactoryDefaultDisable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.NvdimmFactoryDefault23 (Read or Write) Description Reset an NVDIMM-N to its Factory Default state, and erase the NVDIMM-N data. WARNING: All contents in NVDIMM-N will be lost if changes are saved when exiting BIOS! Legal Values ● NvdimmFactoryDefaultEnable ● NvdimmFactoryDefaultDisable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFirmwareVer4 (Read or Write) Description Indicates firmware version used in this NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.NvdimmFirmwareVer8 (Read or Write) Description Indicates firmware version used in this NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFirmwareVer9 (Read or Write) Description Indicates firmware version used in this NVDIMM-N.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFreq1 (Read or Write) Description Indicates the clock frequency of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFreq2 (Read or Write) Description Indicates the clock frequency of NVDIMM-N.
BIOS.MemSettings.NvdimmFreq5 (Read or Write) Description Indicates the clock frequency of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFreq6 (Read or Write) Description Indicates the clock frequency of NVDIMM-N.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFreq10 (Read or Write) Description Indicates the clock frequency of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmFreq11 (Read or Write) Description Indicates the clock frequency of NVDIMM-N.
Dependency Not applicable BIOS.MemSettings.NvdimmLocation1 (Read or Write) Description Indicates the slot location of the NVDIMM-N. This location is printed right next to each DIMM slot on the main system board. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmLocation2 (Read or Write) Description Indicates the slot location of the NVDIMM-N.
BIOS.MemSettings.NvdimmLocation5 (Read or Write) Description Indicates the slot location of the NVDIMM-N. This location is printed right next to each DIMM slot on the main system board. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmLocation6 (Read or Write) Description Indicates the slot location of the NVDIMM-N.
BIOS.MemSettings.NvdimmLocation9 (Read or Write) Description Indicates the slot location of the NVDIMM-N. This location is printed right next to each DIMM slot on the main system board. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmLocation10 (Read or Write) Description Indicates the slot location of the NVDIMM-N.
BIOS.MemSettings.NvdimmSerialNum0 (Read or Write) Description Indicates firmware version used in this NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSerialNum1 (Read or Write) Description Indicates firmware version used in this NVDIMM-N.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSerialNum5 (Read or Write) Description Indicates firmware version used in this NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSerialNum6 (Read or Write) Description Indicates firmware version used in this NVDIMM-N.
BIOS.MemSettings.NvdimmSerialNum9 (Read or Write) Description Indicates firmware version used in this NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSerialNum10 (Read or Write) Description Indicates firmware version used in this NVDIMM-N.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSize2 (Read or Write) Description Indicates the amount of NVDIMM-N in the DIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSize3 (Read or Write) Description Indicates the amount of NVDIMM-N in the DIMM.
BIOS.MemSettings.NvdimmSize6 (Read or Write) Description Indicates the amount of NVDIMM-N in the DIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSize7 (Read or Write) Description Indicates the amount of NVDIMM-N in the DIMM.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.NvdimmSize11 (Read or Write) Description Indicates the amount of NVDIMM-N in the DIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.OppSrefEn (Read or Write) Description This field enables/disables opportunistic self-refresh feature.
● OneShot ● Enable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PersistentMemoryType (Read or Write) Description Select the type of the persistent memory capacity to create. Legal Values ● PmAppDirect ● PmAppDirectNotInterleaved Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PersistentMemoryType3 (Read or Write) Description Persistent memory type Legal Values ● AppDirect ● AppDirectNotInterleaved Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmControllerRevisionID02 (Read or Write) Description [DimmCapabilities==NVDIMM] [DimmCapabilities==AEP] [DimmCapabilities==PMEM] Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PmControllerRevisionID06 (Read or Write) Description [DimmCapabilities==NVDIMM] [DimmCapabilities==AEP] [DimmCapabilities==PMEM] Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmControllerRevisionID12 (Read or Write) Description [DimmCapabilities==NVDIMM] [DimmCapabilities==AEP] [DimmCapabilities==PMEM] Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PmControllerRevisionID16 (Read or Write) Description [DimmCapabilities==NVDIMM] [DimmCapabilities==AEP] [DimmCapabilities==PMEM] Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmControllerRevisionID21 (Read or Write) Description [DimmCapabilities==NVDIMM] [DimmCapabilities==AEP] [DimmCapabilities==PMEM] Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm00InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm01InfoRef (Read or Write) Description View Intel Persistent Memory details.
BIOS.MemSettings.PmDimm04InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm05InfoRef (Read or Write) Description View Intel Persistent Memory details.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm09InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm10InfoRef (Read or Write) Description View Intel Persistent Memory details.
BIOS.MemSettings.PmDimm13InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm14InfoRef (Read or Write) Description View Intel Persistent Memory details.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm18InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm19InfoRef (Read or Write) Description View Intel Persistent Memory details.
BIOS.MemSettings.PmDimm22InfoRef (Read or Write) Description View Intel Persistent Memory details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmDimm23InfoRef (Read or Write) Description View Intel Persistent Memory details.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmLockState02 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported.
● PmLockStateNotSupported ● PmLockStateExceeded Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmLockState05 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported.
● ● ● ● ● PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmLockState08 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported.
Legal Values ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control PmLockStateUnknown PmLockStateDisabled PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmLockState11 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported.
BIOS.MemSettings.PmLockState13 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control PmLockStateUnknown PmLockStateDisabled PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PmLockState16 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control PmLockStateUnknown PmLockStateDisabled PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PmLockState19 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control PmLockStateUnknown PmLockStateDisabled PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PmLockState22 (Read or Write) Description The security state of this NVDIMM as unknown, disabled, unlocked, locked, frozen, max password, and not supported. Legal Values ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control PmLockStateUnknown PmLockStateDisabled PmLockStateUnlocked PmLockStateLocked PmLockStateFrozen PmLockStateNotSupported PmLockStateExceeded License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
● ● ● ● ● ● ● ● ● ● Percent55 Percent60 Percent65 Percent70 Percent75 Percent80 Percent85 Percent90 Percent95 PmPercent100 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmNVMPerformanceSetting (Read or Write) Description NVM baseline performance settings depending on the workload behavior. BW Optimized - Optimized for DDR and DDRT Bandwith.
● Percent90 ● Percent95 ● PmPercent100 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion00InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion04InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion05InfoRef (Read or Write) Description View region details.
BIOS.MemSettings.PmRegion08InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion09InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion13InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion14InfoRef (Read or Write) Description View region details.
BIOS.MemSettings.PmRegion17InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion18InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion22InfoRef (Read or Write) Description View region details. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PmRegion23InfoRef (Read or Write) Description View region details.
Dependency Not applicable BIOS.MemSettings.PmSocket1 (Read or Write) Description NVDIMM region creation for socket01 IntelPersistMemOperationTarget==Socket Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Dependency Not applicable BIOS.MemSettings.Pool01 (Read or Write) Description Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.Pool02 (Read or Write) Description Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PoolCapacity1 (Read or Write) Description Pool Capacity Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.PoolID1 (Read or Write) Description Pool ID Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.PoolID2 (Read or Write) Description Pool ID Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values ● Memory ● Cache ● Hybrid Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.ProcEmbMemSystemSize (Read or Write) Description Displays flat size of the MCDRAM Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
the contents of that rank will be copied to the spare memory to prevent catastrophic memory failure. Note that in Spare Mode, the memory size reported to the OS does not include the spare portion. Default: Disabled For Spare Mode: Has a dependency on DIMM population where within a given channel, multi-rank DIMM or multi single rank DIMM needs to be populated.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance1 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance5 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance9 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance13 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance17 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.RemainingRatedWriteEndurance21 (Read or Write) Description Indicates remaining storage lifetime percentage of NVDIMM-N. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
● InProgress ● Completed Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus01 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed.
BIOS.MemSettings.SanitizeStatus04 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus05 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus08 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus12 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed.
BIOS.MemSettings.SanitizeStatus15 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus16 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus19 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control Unknown NotStarted InProgress Completed License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SanitizeStatus23 (Read or Write) Description The sanitize status of this NVDIMM as unknown, not started, in progress, and completed.
BIOS.MemSettings.SecureErase02 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase03 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
BIOS.MemSettings.SecureErase06 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase07 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
BIOS.MemSettings.SecureErase10 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase11 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
BIOS.MemSettings.SecureErase14 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase15 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
BIOS.MemSettings.SecureErase18 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase19 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
BIOS.MemSettings.SecureErase22 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SecureErase23 (Read or Write) Description Enable or Disable Secure Erase Persistent Memory.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber03 (Read or Write) Description The serial number of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
BIOS.MemSettings.SerialNumber07 (Read or Write) Description The serial number of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber08 (Read or Write) Description The serial number of this NVDIMM.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber12 (Read or Write) Description The serial number of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber13 (Read or Write) Description The serial number of this NVDIMM.
BIOS.MemSettings.SerialNumber16 (Read or Write) Description The serial number of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber17 (Read or Write) Description The serial number of this NVDIMM.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber21 (Read or Write) Description The serial number of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SerialNumber22 (Read or Write) Description The serial number of this NVDIMM.
BIOS.MemSettings.SnoopMode (Read or Write) Description Allows tuning of memory performances under different memory bandwidths. The optimal Snoop Mode setting is highly dependent on workload type. Early Snoop is best used for latency sensitive workloads. This setting offers the best balance between workload effects. Home Snoop is best used for NUMA workloads that need maximum local and remote memory bandwidth. Cluster on Die is best used for highly NUMA optimized workloads.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SocketID3 (Read or Write) Description Socket ID Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz00 (Read or Write) Description The speed of this NVDIMM.
BIOS.MemSettings.SpeedMHz03 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz04 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz08 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz09 (Read or Write) Description The speed of this NVDIMM.
BIOS.MemSettings.SpeedMHz12 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz13 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz17 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz18 (Read or Write) Description The speed of this NVDIMM.
BIOS.MemSettings.SpeedMHz21 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SpeedMHz22 (Read or Write) Description The speed of this NVDIMM. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SysMemType (Read or Write) Description Indicates the type of main memory installed in the system. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.SysMemVolt (Read or Write) Description Indicates the current operating voltage of main memory.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MemSettings.VideoMem (Read or Write) Description Indicates the total amount of video memory available to the embedded video controller. [Zhengyu]:Not used in 13G Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Dependency Not applicable BIOS.MiscSettings.DellWyseP25BIOSAccess (Read or Write) Description Controls remote user access to BIOS Setup via Dell Wyse P25/P45 Portal. When set to Disabled, pre-OS keyboard and mouse access is prevented, including to Diagnostics and Boot Options. It cannot be set back to Enabled from the P25/P45.
seconds to execute, and system reset is required for ISC results to be applied. The Enabled - No Reboot option executes ISC and continues without applying ISC results until the next time system reset occurs. The Enabled option executes ISC and forces an immediate system reset so that ISC results can be applied right away. It takes the system longer to be ready due to the forced system reset. When disabled, ISC will not execute. R530, R530XD, R430, T430, R330, T330, R230, and T130 do not support ISC.
● FullPowerCycle Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MiscSettings.ReportKbdErr (Read or Write) Description This field sets whether keyboard-related error messages are reported at system startup. Legal Values ● Report ● NoReport Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.MiscSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings This group contains the attributes that provides details about BIOS.NetworkSettings. BIOS.NetworkSettings.AdditionalPxeDevices (Read or Write) Description When enabled, add 12 more PXE device. Legal Values ● Disabled ● Enabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings.HttpDev2SettingsRef (Read or Write) Description View and/or modify this device's boot configuration. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings.
BIOS.NetworkSettings.HttpDev4SettingsRef (Read or Write) Description View and/or modify this device's boot configuration. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings.IscsiDev1EnDis (Read or Write) Description This field controls the configuration for this iSCSI device.
Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.NetworkSettings.PxeDev3EnDis (Read or Write) Description PXE device Enable/Disable. When enabled, a UEFI boot option will be created for the PXE device.
BIOS.NvmeSettings.NvmeMode (Read or Write) Description If the system contains NVMe drives that you want to configure in a RAID array, you must set both this field and the Embedded SATA field on the SATA Settings menu to RAID Mode. You may also need to change the Boot Mode setting to UEFI. Otherwise, you should set this field to Non-RAID Mode.
Dependency Not applicable BIOS.OneTimeBoot.OneTimeBoot (Read or Write) Description This field supports a one-time boot to a specified device. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Description This field enables the boot device list from which a boot device can be selected.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.OneTimeBoot.OneTimeCustomBootStr (Read or Write) Description This field determines the one-time boot device when the One-Time Boot Device List is set to one of the Custom String options. The system may temporarily switch to the correct boot mode based on the One-Time Boot Device List setting.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.OneTimeBoot.OneTimeUefiBootSeq (Read or Write) Description This field determines the one-time boot device when the One-Time Boot Device List is set to UEFI Boot Sequence Device. If Boot Mode is set to BIOS, the system temporarily switches the Boot Mode to UEFI when attempting a one-time boot to the device.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.CcxAsNumaDomain (Read or Write) Description This field specifies that each CCX within the processor will be declared as a NUMA Domain. Legal Values ● Enabled ● Disabled ● Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.ControlledTurboMinusBin (Read or Write) Description Enter a value from 0 to 12 bins. The value entered decreases the Dell AVX Scaling Technology frequency when the Dell Controlled Turbo feature is enabled. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.CpuFeatureRmss (Read or Write) Description Enables or disables REP-MOV/STOS Streaming support. This setting can affect performance, depending on the application running on the server. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
Dependency Not applicable BIOS.ProcSettings.DataReuse (Read or Write) Description When set to Enabled, allows the processor to retain frequently used lines in all levels of cache at the expense of some control signals between the processor and cache. Legal Values ● Disabled ● Enabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.DynamicCoreAllocation (Read or Write) Description Logical Processor Idling (LPI) is a collaborative interface between platform and Operating System that helps to improve the energy efficiency of a system. This feature is required in those cases where customer has a need to go for power budgeting.
BIOS.ProcSettings.IrqThrottle (Read or Write) Description Throttles local requests that are targeting a remote address." Legal Values ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control 0 1 2 3 4 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.L1Prefetcher (Read or Write) Description Enables or disables the L1 Prefetcher. This setting can affect performance, depending on the application running on the server.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.L1StridePrefetcher (Read or Write) Description When set to Enabled, the processor provides additional fetch to the data access for an individual instruction for performance tuning by controlling the L1 stride prefetcher setting. Use the recommended setting and this option will allow for optimizing overall workloads.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.L2UpDownPrefetcher (Read or Write) Description When set to Enabled, the processor uses memory access to determine whether to fetch next or previous for all memory accesses for advanced performance tuning by controlling the L2 up/down prefetcher setting. Use the recommended setting and this option will allow for optimizing overall workloads.
BIOS.ProcSettings.MadtCoreEnumeration (Read or Write) Description This field determines how BIOS enumerates processor cores in the ACPI MADT table. When set to Round Robin, Processor cores are enumerated in a Round Robin order to evenly distribute interrupt controllers for the OS across all Sockets and Dies. When set to Linear, Processor cores are enumerated across all Dies within a Socket before enumerating additional Sockets for a linear distribution of interrupt controllers for the OS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc1Brand (Read or Write) Description This field displays the brand text provided by the processor manufacturer. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.Proc1Cores (Read or Write) Description Controls the number of enabled cores in the processor. Under certain circumstances, you may see limited performance improvements to Intel Turbo Boost Technology and benefit from potentially larger shared caches if you reduce the number of enabled cores. Most computing environments tend to benefit more from larger number of processing cores, so you must carefully weigh the disabling of cores to gain nominal performance enhancements.
BIOS.ProcSettings.Proc1L3Cache (Read or Write) Description Displays the amount of memory in the corresponding processor cache. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc1MaxMemoryCapacity (Read or Write) Description Displays the maximum amount of system memory supported by this processor.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc2ControlledTurbo (Read or Write) Description Helps control the turbo engagement for processor 2. This option is active when System Profile is set to Performance, or when System Profile is set to Custom, CPU Power Management is set to Maximum Performance, and Turbo Boost enabled. A DPAT Pro license is needed to enable this feature.
● ● ● ● ● ● ● ● ● ● ● ● ● 4 6 8 10 12 14 16 18 20 22 24 26 28 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc2Id (Read or Write) Description Displays the processor's family, model, and stepping values. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.Proc2MaxMemoryCapacity (Read or Write) Description Displays the maximum amount of system memory supported by this processor. Available only when "max memory capacity" data is provided by the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc2Microcode (Read or Write) Description Indicates the microcode update signature.
No dependency, however this setting is only valid when the CPU Power Management is set to Maximum Performance.If the CPU Power Management is not set to Maximum Performance, the customer can still change it but it will have no effect. A DPAT Pro license is needed to expose this field.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc3Id (Read or Write) Description Displays the processor's family, model, and stepping values. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.Proc3Microcode (Read or Write) Description Indicates the microcode update signature. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc3NumCores (Read or Write) Description Displays the number of cores in the processor package.
Dependency Not applicable BIOS.ProcSettings.Proc4ControlledTurboMinusBin (Read or Write) Description For processor 4, when the Dell Controlled Turbo feature is enabled and set to Custom, the value entered decreases the Dell AVX Scaling Technology frequency. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc4L2Cache (Read or Write) Description This field displays the amount of memory in the corresponding processor cache. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.
BIOS.ProcSettings.Proc4NumCores (Read or Write) Description This field displays the number of cores in the processor package. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.Proc64bit (Read or Write) Description Indicates whether or not the installed processor(s) support 64-bit extensions.
BIOS.ProcSettings.ProcBusSpeed (Read or Write) Description Displays the bus speed of the processor(s). Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.ProcCcds (Read or Write) Description Enable number of CCDs per Processor.
from larger numbers of processing cores, so you must carefully weigh disabling cores to gain nominal performance enhancements. Legal Values ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Single All Dual Quad 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 32 Custom License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.ProcCoreSpeed (Read or Write) Description Displays the rated clock speed of the processor(s).
● Four4Plus0 ● Six3Plus3 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.ProcDramPrefetcher (Read or Write) Description When set to Enabled, turns on the DRAM prefetch unit in the Northbridge. When set to Disabled, prevents DRAM references from triggering DRAM prefetch requests.
BIOS.ProcSettings.ProcExecuteDisable (Read or Write) Description A security feature designed to prevent certain types of buffer overflow attacks by enforcing specific areas of memory that applications can execute code. In general, it is best pratice to leave this option set to Enabled for the security benefits, as no real performance advantage has been detected by disabling this feature in BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.ProcHyperTransport (Read or Write) Description Specifies the supported HyperTransport I/O Link Specification. If the system board and all installed processors support HT 3, this field is settable to HT 3 or HT 1, else this field will become Read-Only and set to HT 1.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.ProcSettings.ProcVirtualization (Read or Write) Description When set to Enabled, the BIOS will enable processor Virtualization features and provide the virtualization support to the Operating System (OS) through the DMAR table.
BIOS.ProcSettings.QpiSpeed (Read or Write) Description The Intel QuickPath Interconnect (QPI) Speed option in the Processor section governs the frequency of the QPI links between the populated processors. The user should be aware that standard and basic bin Intel processors of this architecture support slower QPI link speeds than the advanced parts provide. Maximum Data Rate indicates that the BIOS will run the QPI links at the maximum frequency supported by the processor.
Dependency Not applicable BIOS.ProcSettings.UpiPrefetch (Read or Write) Description UPI Prefetch is a mechanism too get the memory read started early on DDR bus, the UPI Rx path will spawn a MemSpecRd to iMC directly. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PowerMgmtSettings You can manage the power management settings using the objects in this group. BIOS.
● 800Mhz ● MinPwr Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PowerMgmtSettings.PowerMgmt (Read or Write) Description Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control OsCtrl ActivePwrCtrl Custom MaxPerf License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PowerMgmtSettings.
BIOS.PxeDev1Settings.PxeDev1Protocol (Read or Write) Description This field controls the PXE protocol used for this PXE device. Legal Values ● IPv4 ● IPv6 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev1Settings.PxeDev1VlanEnDis (Read or Write) Description VLAN Enable/Disable for this PXE device.
BIOS.PxeDev2Settings.PxeDev2Interface (Read or Write) Description NIC Interface used for this PXE device. Legal Values ● *Dynamic* Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev2Settings.PxeDev2Protocol (Read or Write) Description This field controls the PXE protocol used for this PXE device.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev3Settings This group contains the attributes that provides details about BIOS.PxeDev3Settings. BIOS.PxeDev3Settings.PxeDev3Interface (Read or Write) Description NIC Interface used for this PXE device.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev3Settings.PxeDev3VlanPriority (Read or Write) Description VLAN priority for this PXE device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev4Settings.PxeDev4VlanId (Read or Write) Description VLAN ID for this PXE device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.PxeDev4Settings.
BIOS.RedundantOsControl.RedundantOsLocation (Read or Write) Description Specifies the backup device for the Redundant OS Control feature. When Redundant OS Boot is set to Enabled, the BIOS will boot to this device. Note: 1) SD Card Port, Internal USB Port, M.2 cards - If a device is set as the Redundant OS Location, then the corresponding device setting will be set based on Redundant OS state and not be available to be changed in Integrated Devices.
BIOS.SataSettings.EmbSataShadow (Read or Write) Description For internal use. No dependency, AND should NOT be used by any teams except BIOS. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control AtaMode AhciMode RaidMode Off License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.eSataPort1 (Read or Write) Description Sets the drive type of the selected device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.eSataPort1Model (Read or Write) Description Indicates the drive model of the selected device. NA Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortA (Read or Write) Description Sets the drive type of the selected device.
This attribute is supressed if Sata Mode is RAID or the platform supports less than 1 onboard SATA port. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortAModel (Read or Write) Description Indicates the drive model of the selected device. This attribute is supressed if Sata Mode is RAID or the platform supports less than 1 onboard SATA port.
BIOS.SataSettings.SataPortBDriveType (Read or Write) Description Indicates type of device attached to this SATA port. This attribute is supressed if Sata Mode is RAID or the platform supports less than 2 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortBModel (Read or Write) Description Indicates the drive model of the selected device.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortCDriveType (Read or Write) Description Indicates type of device attached to this SATA port. This attribute is supressed if Sata Mode is RAID or the platform supports less than 3 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.
Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortDDriveType (Read or Write) Description Indicates type of device attached to this SATA port. This attribute is supressed if Sata Mode is RAID or the platform supports less than 4 onboard SATA ports.
BIOS.SataSettings.SataPortECapacity (Read or Write) Description Indicates the total capacity of a hard-disk drive. This field is undefined for removable-media devices such as optical drives. This attribute is supressed if Sata Mode is RAID or the platform supports less than 5 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortFCapacity (Read or Write) Description Indicates the total capacity of a hard-disk drive. This field is undefined for removable-media devices such as optical drives. This attribute is supressed if Sata Mode is RAID or the platform supports less than 6 onboard SATA ports.
● Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortGCapacity (Read or Write) Description Indicates the total capacity of a hard-disk drive. This field is undefined for removable-media devices such as optical drives. This attribute is supressed if Sata Mode is RAID or the platform supports less than 7 onboard SATA ports.
This attribute is shown if platform supports at least 8 onboard SATA ports. This attribute is grayed out if Sata Mode is NOT ATA. Legal Values ● Off ● Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortHCapacity (Read or Write) Description Indicates the total capacity of a hard-disk drive. This field is undefined for removable-media devices such as optical drives.
BIOS.SataSettings.SataPortI (Read or Write) Description Sets the drive type of the selected device. When the Embedded SATA setting is ATA Mode, set this field to Auto to enable BIOS support for the device. Select Off to turn off BIOS support for the device. When the Embedded SATA setting is AHCI Mode or RAID Mode, BIOS always enables support for the device and this field is read-only. This attribute is shown if platform supports at least 9 onboard SATA ports.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortJ (Read or Write) Description Sets the drive type of the selected device. When the Embedded SATA setting is ATA Mode, set this field to Auto to enable BIOS support for the device. Select Off to turn off BIOS support for the device. When the Embedded SATA setting is AHCI Mode or RAID Mode, BIOS always enables support for the device and this field is read-only.
This attribute is supressed if Sata Mode is RAID or the platform supports less than 10 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortK (Read or Write) Description Sets the drive type of the selected device. When the Embedded SATA setting is ATA Mode, set this field to Auto to enable BIOS support for the device.
BIOS.SataSettings.SataPortKModel (Read or Write) Description Indicates the drive model of the selected device. This attribute is supressed if Sata Mode is RAID or the platform supports less than 7 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortL (Read or Write) Description Sets the drive type of the selected device.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortLModel (Read or Write) Description Indicates the drive model of the selected device. Indicates the drive model of the selected device. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortM (Read or Write) Description Sets the drive type of the selected device.
Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortMModel (Read or Write) Description Indicates the drive model of the selected device. This attribute is supressed if Sata Mode is RAID or the platform supports less than 7 onboard SATA ports.
BIOS.SataSettings.SataPortNDriveType (Read or Write) Description Indicates type of device attached to this SATA port. This attribute is supressed if Sata Mode is RAID or the platform supports less than 7 onboard SATA ports. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SataSettings.SataPortNModel (Read or Write) Description Indicates the drive model of the selected device.
BIOS.SataSettings.WriteCache (Read or Write) Description Sends Enable or Disable Write Cache command to the Embedded SATA drives during POST. This option is only applicable to ATA, AHCI mode, and is not applicable to RAID mode. This has the value of Disabled (read-only) if Sata Mode is Raid or Off. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
BIOS.SerialCommSettings.FailSafeBaud (Read or Write) Description If the BIOS fails to determine the baud rate automatically, then it will use the baud rate specified by this field. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control 115200 57600 19200 9600 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SerialCommSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SerialCommSettings.SerialPortAddress (Read or Write) Description This field sets port address for the Serial Devices. (COM1=0x3F8, COM2=0x2F8) Note: Only Serial Device 2 can be used for Serial Over LAN (SOL). To get Console Redirection via SOL, configure the same port address for Console Redirection and Serial Device.
slot will bifurcate x8 link plus two x4 links NOTE: Only bifurcation options that the slot can support will be shown. Legal Values ● ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Allx16 Allx8 Allx4 x4 x16 x8 x4x4x8 x8x4x4 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.Slot11Bif (Read or Write) Description Controls the bifurcation of PCIe cards installed in the specified slot.
● ● ● ● x16 x8 x4x4x8 x8x4x4 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.Slot13Bif (Read or Write) Description Controls the bifurcation of PCIe cards installed in the specified slot. When set to default, the slot will operate at the default bifurcation for that slot. When set to x4 All Bifurcation, the slot will bifurcate to either two or four x4 links depending on the slot capability.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.Slot1Bif (Read or Write) Description Controls the bifurcation of PCIe cards installed in the specified slot. When set to default, the slot will operate at the default bifurcation for that slot. When set to x4 All Bifurcation, the slot will bifurcate to either two or four x4 links depending on the slot capability. When set to x8 All Bifurcation the slot will bifurcate to two x8 links.
BIOS.SlotBifurcation.Slot3Bif (Read or Write) Description Controls the bifurcation of PCIe cards installed in the specified slot. When set to default, the slot will operate at the default bifurcation for that slot. When set to x4 All Bifurcation, the slot will bifurcate to either two or four x4 links depending on the slot capability. When set to x8 All Bifurcation the slot will bifurcate to two x8 links. When set to x16 All Bifurcation the slot will bifurcate to x16 links.
x4 x8 Bifurcation the slot will bifurcate to two 4 links plus a x8 link When set to x8 x4 x4 Bifurcation the slot will bifurcate x8 link plus two x4 links NOTE: Only bifurcation options that the slot can support will be shown. Legal Values ● ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control Allx16 Allx8 Allx4 x4 x16 x8 x4x4x8 x8x4x4 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.
● ● ● ● ● x4 x16 x8 x4x4x8 x8x4x4 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.Slot8Bif (Read or Write) Description Controls the bifurcation of PCIe cards installed in the specified slot. When set to default, the slot will operate at the default bifurcation for that slot.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotBifurcation.SlotBifurcation (Read or Write) Description Controls the bifurcation of the specified slot. Only slots that are present on the system will be available for control. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
the card is available to the operating system. Note: This option is not available if the slot contains a Dell PowerEdge RAID card (PERC). This option is not available if the slot contains the primary video display adapter. Note: Some PCIe device manufacturers implement a master boot driver that can initialize and manage all the similar devices in the system.
● BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotDisablement.Slot5 (Read or Write) Description Controls the configuration of PCIe cards installed in the specified slot. Slot disablement must be used only when the installed peripheral card is preventing booting into the operating system or causing delays or lockups in system startup.
BIOS.SlotDisablement.Slot7 (Read or Write) Description Controls the configuration of PCIe cards installed in the specified slot. Slot disablement must be used only when the installed peripheral card is preventing booting into the operating system or causing delays or lockups in system startup. When set to Disabled, both the Option ROM and UEFI driver are disabled, the card is not enumerated on the PCI bus, and will not be available to the operating system.
the card is available to the operating system. Note: This option is not available if the slot contains a Dell PowerEdge RAID card (PERC). This option is not available if the slot contains the primary video display adapter. Note: Some PCIe device manufacturers implement a master boot driver that can initialize and manage all the similar devices in the system.
● BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SlotDisablement.Slot12 (Read or Write) Description Controls the configuration of PCIe cards installed in the specified slot. Slot disablement must be used only when the installed peripheral card is preventing booting into the operating system or causing delays or lockups in system startup.
BIOS.SlotDisablement.SlotDisablement (Read or Write) Description Controls the configuration of PCIe cards installed in the specified slot. Only slots that are present on the system will be available for control. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysInformation To view information about system configuration, use the objects in this group. BIOS.SysInformation.
BIOS.SysInformation.SysInformation (Read or Write) Description This field displays information which uniquely identifies this system. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysInformation.SysMfrContactInfo (Read or Write) Description Indicates the contact information of the Original Equipment Manufacturer (OEM).
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysInformation.SystemManufacturer (Read or Write) Description Indicates the name of the Original Equipment Manufacturer (OEM). Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysInformation.
BIOS.SysInformation.UefiComplianceVersion (Read or Write) Description Indicates the UEFI compliance level of the system firmware. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings To manage the system profile settings, use the objects in this group. BIOS.SysProfileSettings.
BIOS.SysProfileSettings.CpuInterconnectBusLinkPower (Read or Write) Description When enabled, CPU interconnect bus link power management is enabled Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.DeterminismSlider (Read or Write) Description It controls whether BIOS will enable determinism to control performance.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.EfficiencyOptimizedMode (Read or Write) Description Efficiency Optimized Mode maximizes Performance-per-Watt by opportunistically reducing frequency/ power.This field enables/disables Efficiency Optimized Mode.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.FixedSocPstate (Read or Write) Description This value defines the forced P-state when ApbDis is enabled. Legal Values ● ● ● ● Default Value Not Applicable Write Privilege Server Control FixedSocPstate0 FixedSocPstate1 FixedSocPstate2 FixedSocPstate3 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.
Has a dependency on the System Profile. Can only be set if the System Profile is set to Custom. Is set to Standard if the System Profile is set to Performance Per Watt (DAPC), Performance Per Watt (OS), Performance Per Watt (HWPM), or Performance. Is set to Extended if the System Profile is set to Dense. Legal Values ● Standard ● Extended ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
Legal Values ● AutoVolt ● Volt135V ● Volt15V Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.MonitorMwait (Read or Write) Description Specifies whether Monitor/Mwait instructions are enabled. Read-only unless System Profile is set to Custom. Has a dependency on the System Profile. Can only be set if the System Profile is set to Custom. Is set to Enabled for all the other System Profiles.
BIOS.SysProfileSettings.PowerSaver (Read or Write) Description When set to Enabled, maximizes power savings, at the expense of performance. Read-only unless System Profile is set to Custom. Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.Proc1TurboCoreNum (Read or Write) Description Controls the number of Turbo Boost enabled cores for processor 1.
Legal Values ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Default Value Not Applicable Write Privilege Server Control All 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.Proc3TurboCoreNum (Read or Write) Description Controls the number of Turbo Boost enabled cores for processor 3. By reducing the number of cores enabled with Turbo Boost, the maximum turbo frequency on the cores with Turbo Boost may be higher.
BIOS.SysProfileSettings.Proc4TurboCoreNum (Read or Write) Description Controls the number of Turbo Boost enabled cores for processor 4. By reducing the number of cores enabled with Turbo Boost, the maximum turbo frequency on the cores with Turbo Boost may be higher. Read-only unless System Profile is set to Custom, Turbo Boost is set to Enabled and CPU Power Management is set to Maximum Performance. Has a dependency on the System Profile. Can only be set if the System Profile is set to Custom.
Has a dependency on the System Profile. Can only be set if the System Profile is set to Custom. Is set to Enabled if the System Profile is set to Performance Per Watt (DAPC), Performance Per Watt (OS), Performance Per Watt (HWPM), or Dense. Is set to Disabled if the System Profile is set to Performance. Legal Values ● Disabled ● Enabled ● Autonomous Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.
BIOS.SysProfileSettings.ProcTurboMode (Read or Write) Description Governs the Intel Turbo Boost Technology. This feature allows the processor cores to be automatically clocked up in frequency beyond the advertised processor speed. The amount of increased frequency (or 'turbo upside') one can expect from a Xeon processor depends on the processor model, thermal limitations of the operating environment, and in some cases power consumption.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.SysProfileSettings (Read or Write) Description Indicates the fields by using which you can control the System Profile settings. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.UncoreFrequency (Read or Write) Description Selects the Processor Uncore Frequency.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysProfileSettings.WriteDataCrc (Read or Write) Description When set to Enabled, DDR4 data bus faults are detected and corrected during 'write' operations. Two additional cycles are required for CRC bit generation which results in performance impact. Read-only unless System Profile is set to Custom. Has a dependency on the System Profile. Can only be set if the System Profile is set to Custom.
Not supported on blades. Legal Values ● Immediate ● User ● Random Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.AcPwrRcvryUserDelay (Read or Write) Description Controls the duration for which the power-on process is delayed after the AC power supply is restored. The value is only effective if AC Power Recovery Delay is set to User Defined. The valid range is between 60s and 240s.
BIOS.SysSecurity.BiosUpdateControl (Read or Write) Description When set to Unlocked, all BIOS update will be allowed. When set to Limited, local BIOS updates from DOS or UEFI shell based flash utilities, or from Lifecycle Controller User Interface are prohibited. Limited is recommended for environments that do not require local BIOS updates. These environments include Remote Enablement Update or executing Update Package from the OS.
Legal Values ● Off ● On ● Software Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.IntelTxt (Read or Write) Description Allows enabling or disabling of the Intel Trusted Execution Technology (TXT). To enable Intel TXT, Virtualization Technology must be enabled, TPM Security must be set to On with Pre-boot Measurements, and TPM Status must be Enabled, Activated.
Legal Values ● Enabled ● Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.OldSetupPassword (Read or Write) Description Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.SecureBoot (Read or Write) Description Allows enabling of Secure Boot, where the BIOS authenticates each component that is executed during the boot process using the certificates in the Secure Boot Policy.
BIOS.SysSecurity.SecureBootPolicy (Read or Write) Description Allows selecting the Secure Boot Policy. When set to Standard, the BIOS uses the key and certificates from the system manufacturer to authenticate pre-boot images. When set to Custom, the BIOS uses the user-customized key and certificates. Note: If Custom mode is selected, the Secure Boot Custom Policy Settings menu is displayed. Note: Changing the default security certificates may cause the system to fail booting from certain boot options.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.SHA256SystemPassword (Read or Write) Description SHA256 hash of the system password. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.SHA256SystemPasswordSalt (Read or Write) Description Salt for hash of the system password.
BIOS.SysSecurity.SysSecurity (Read or Write) Description Controls the security features of the system. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.TcmActivation (Read or Write) Description Indicates the operational state of the Trusted Cryptography Module (TCM). When set to Activate, the TCM will be enabled and activated.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.Tpm2Hierarchy (Read or Write) Description Allows enabling, disabling, or clearing the storage and endorsement hierarchies. When set to Enabled, the storage and endorsement hierarchies can be used. When set to Disabled, the storage and endorsement hierarchies cannot be used. When set to Clear, the storage and endorsement hierarchies are cleared of any values, and then reset to Enabled.
BIOS.SysSecurity.TpmCommand (Read or Write) Description Controls the Trusted Platform Module (TPM). When set to None, no command is sent to the TPM. When set to Activate, the TPM will be enabled and activated. When set to Deactivate, the TPM will be disabled and deactivated. When set to Clear, all the contents of the TPM will be cleared. WARNING: Clearing the TPM will result in losing all keys in the TPM. This could affect booting to the OS. This field is read-only when TPM Security is set to Off.
● On Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.SysSecurity.TpmStatus (Read or Write) Description Displays the current status of the Trusted Platform Module (TPM), and is applicable only for TPM 1.2. If the TPM is not present or TPM Security is set to Off, the value is set to Unknown.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.TpmAdvancedSettings.TpmPpiBypassClear (Read or Write) Description When set to Enabled, allows the Operating System to bypass Physical Presence Interface (PPI) prompts when issuing PPI Advanced Configuration and Power Interface (ACPI) clear operations.
BIOS.UefiBootSettings This group contains the attributes that provides details about BIOS.UefiBootSettings. BIOS.UefiBootSettings.UefiBootSeq (Read or Write) Description This field controls the UEFI boot order. The first option in the list will be attempted first, and if unsuccessful, the second option will be attempted and so on. This field applies only when Boot Mode is 'UEFI'; it has no effect when Boot Mode is 'BIOS'.
Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.UefiBootSettings.UefiBootSeqEnDis4 (Read or Write) Description This field enables or disables this boot option in the UEFI Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'UEFI'; it has no effect when Boot Mode is 'BIOS'.
BIOS.UefiBootSettings.UefiBootSeqEnDis7 (Read or Write) Description This field enables or disables this boot option in the UEFI Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'UEFI'; it has no effect when Boot Mode is 'BIOS'.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.UefiBootSettings.UefiBootSeqEnDis11 (Read or Write) Description This field enables or disables this boot option in the UEFI Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'UEFI'; it has no effect when Boot Mode is 'BIOS'.
Legal Values ● true ● false Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.UefiBootSettings.UefiBootSeqEnDis15 (Read or Write) Description This field enables or disables this boot option in the UEFI Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options.
BIOS.UefiBootSettings.UefiBootSeqEnDis18 (Read or Write) Description This field enables or disables this boot option in the UEFI Boot Sequence. The system will attempt to launch enabled boot options only; it will not launch disabled boot options. This field applies only when Boot Mode is 'UEFI'; it has no effect when Boot Mode is 'BIOS'.
BIOS.UefiBootSettings.UefiBootSettings (Read or Write) Description This field controls system boot settings when Boot Mode is set to 'UEFI'. This field has no effect when Boot Mode is set to 'BIOS'. Legal Values ● N/A Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable BIOS.UefiBootSettings.
3 FC Attributes This section provides details about the FC attribute groups and objects. Topics: • • • • • FC.FCDevice FC.FCTarget FC.HBAConfig FC.PortConfig FC.Top FC.FCDevice The following section provides information about the objects in the FC.FCDevice group. FC.FCDevice.BusDeviceFunction (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.FCDevice.
FC.FCDevice.FamilyVersion (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.FCDevice.PCIDeviceID (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.FCTarget The following section provides information about the objects in the FC.FCTarget group. FC.FCTarget.
License Required Dependency Not Applicable FC.FCTarget.FirstFCTargetWWPN (Read or Write) Description Specifies the World Wide Port Name of the first Fibre Channel boot target Legal Values None Default Value None Write Privilege Server Configuration License Required Dependency Not Applicable FC.FCTarget.
Dependency Not Applicable FC.HBAConfig.EighthNVMeTargetWWNN (Read or Write) Description Specify the World Wide Node Name of the eighth NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.EighthNVMeTargetWWPN (Read or Write) Description Specify the World Wide Port Name of the eighth NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.
FC.HBAConfig.EighthNVMeTgtNSID (Read or Write) Description Specify the Namespace ID of the eighth NVMe boot target to access.[VENDOR: specify format of value] Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege Server Configuration License Required Dependency Not Applicable FC.HBAConfig.FifthNVMeTargetNQN (Read or Write) Description Specify the fifth target's NVMe Qualified Name Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
Dependency Not Applicable FC.HBAConfig.FifthNVMeTgtConn (Read or Write) Description Setting to enable whether connection to the fifth NVMe Target is attempted Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.FifthNVMeTgtNSID (Read or Write) Description Specify the Namespace ID of the fifth NVMe boot target to access.
FC.HBAConfig.FirstNVMeTargetWWPN (Read or Write) Description Specify the World Wide Port Name of the first NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.FirstNVMeTgtCntlrID (Read or Write) Description Specify the Controller ID of the first NVMe boot target.[VENDOR: specify format of value] Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.FourthNVMeTargetWWNN (Read or Write) Description Specify the World Wide Node Name of the fourth NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
FC.HBAConfig.FourthNVMeTgtNSID (Read or Write) Description Specify the Namespace ID of the fourth NVMe boot target to access.[VENDOR: specify format of value] Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
FC.HBAConfig.LinkDownTimeout (Read or Write) Description Specifies the number of milliseconds the Fibre Channel uplink port can be offline before the system is notified that the SAN fabric connectivity is lost and the uplink port is marked as being down Legal Values None Default Value 3000 Write Privilege Server Configuration License Required Dependency Not Applicable FC.HBAConfig.LoopResetDelay (Read or Write) Description Specifies the Fibre Channel Arbitrated Loop Reset Delay for the port.
FC.HBAConfig.PortLoginRetryCount (Read or Write) Description Specifies the number of times the adapter firmware initiator will try logging into a target device port Legal Values None Default Value 3 Write Privilege Server Configuration License Required Dependency Not Applicable FC.HBAConfig.
Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.SecondNVMeTgtCntlrID (Read or Write) Description Specify the Controller ID of the second NVMe boot target. [VENDOR: specify format of value] Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
FC.HBAConfig.SeventhNVMeTargetWWNN (Read or Write) Description Specify the World Wide Node Name of the seventh NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.SeventhNVMeTargetWWPN (Read or Write) Description Specify the World Wide Port Name of the seventh NVMe boot target Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.SixthNVMeTargetNQN (Read or Write) Description Specify the sixth target's NVMe Qualified Name Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
FC.HBAConfig.SixthNVMeTgtConn (Read or Write) Description Setting to enable whether connection to the sixth NVMe Target is attempted Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.SixthNVMeTgtNSID (Read or Write) Description Specify the Namespace ID of the sixth NVMe boot target to access.
Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.ThirdNVMeTgtCntlrID (Read or Write) Description Specify the Controller ID of the third NVMe boot target.[VENDOR: specify format of value] Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.HBAConfig.
Default Value None Write Privilege None License Required Dependency Not Applicable FC.PortConfig.FCDevice (Read Only) Description View device and firmware version information Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.PortConfig.
FC.PortConfig.PortSpeed (Read or Write) Description Specifies the data rate of the Fibre Channel Host Bus Adapter port. Value can be Automatic or specified in Gbps. Legal Values ● ● ● ● ● ● ● Default Value Auto Write Privilege Server Configuration Auto 1G 2G 4G 8G 16G 32G License Required Dependency Not Applicable FC.PortConfig.
FC.PortConfig.WWPN (Read Only) Description Permanent Fibre Channel World Wide Port Name assigned to the port during manufacturing Legal Values None Default Value None Write Privilege None License Required Dependency Not Applicable FC.Top The following section provides information about the objects in the FC.Top group. FC.Top.PortConfig (Read Only) Description View and configure Fibre Channel Host Bus Adapter information and settings for the adapter and port.
4 iDRAC Attributes This section provides details about the iDRAC attribute groups and objects. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iDRAC.ActiveDirectory iDRAC.ADGroup iDRAC.APSTable iDRAC.ASRConfig iDRAC.Autodiscovery iDRAC.AutoOSLockGroup iDRAC.BootstrapUsers iDRAC.CMCSNMPAlert iDRAC.CMCSNMPTrapIPv6 iDRAC.ConsumerNotify.I2CTopologyReady (Read Only) iDRAC.ConvergedInfra.AppRawData (Read or Write) iDRAC.CPUConfig.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 436 iDRAC.KMS iDRAC.LDAP iDRAC.LDAPRoleGroup iDRAC.LifeCycleLog.EventSequenceNumber (Read Only) iDRAC.LDAPRoleGroup iDRAC.LocalSecurity.KCSAccess (Read or Write) iDRAC.LocalSecurity iDRAC.Lockdown iDRAC.Logging iDRAC.MgmtNetworkInterface iDRAC.NIC iDRAC.NICStatic iDRAC.NonSDLPlugins iDRAC.NTPConfigGroup iDRAC.OCPInformation iDRAC.OS-BMC iDRAC.PCIeVDM iDRAC.Platformcapability iDRAC.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iDRAC.Syslog iDRAC.Telemetry iDRAC.TelemetryAggregateCUPS iDRAC.TelemetryAggregationMetrics iDRAC.TelemetryCPUConfig iDRAC.TelemetryCPUInventory iDRAC.TelemetryCPUMemMetrics iDRAC.TelemetryCPURegisters iDRAC.TelemetryCPUSensor iDRAC.TelemetryCUPS iDRAC.TelemetryFanSensor iDRAC.TelemetryFCConfig iDRAC.TelemetryFCInventory iDRAC.TelemetryFCPortStatistics iDRAC.TelemetryFCSensor iDRAC.
• • • • • • • • • • iDRAC.Update iDRAC.USB iDRAC.Userdomain iDRAC.Users iDRAC.vFlashPartition iDRAC.vFlashSD iDRAC.VirtualConsole iDRAC.VirtualMedia iDRC.VNCServer iDRAC.WebServer iDRAC.ActiveDirectory This group contains the attributes that provides details about ActiveDirectory. iDRAC.ActiveDirectory.AuthTimeout (Read or Write) Description Specifies the number of seconds to wait for Active Directory authentication requests to complete before timing out.
iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write) Description This is the configured search domain to use when DCLookupByUserDomain is disabled Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.DCLookupEnable (Read or Write) Description Configures iDRAC to use pre-configured domain controllers or to use DNS to find the domain controller.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.Enable (Read or Write) Description Enables or disables Active Directory user authentication on iDRAC Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.GCLookupEnable (Read or Write) Description Determines how the global catalog server is looked up.
Dependancy None iDRAC.ActiveDirectory.GlobalCatalog2 (Read or Write) Description Specifies the Global Catalog server from which you want the iDRAC to obtain user names. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.GlobalCatalog3 (Read or Write) Description Specifies the Global Catalog server from which you want the iDRAC to obtain user names.
Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.RacDomain (Read or Write) Description Active Directory Domain in which iDRAC resides. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ActiveDirectory.
License Required Dependancy None iDRAC.ActiveDirectory.SSOEnable (Read or Write) Description Enables or disables Active Directory single sign-on authentication on iDRAC. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy Cannot be Enabled unless SmartCard Logon Enable is Disabled iDRAC.ADGroup This group contains the attributes that provides details about ADGroup. iDRAC.ADGroup.
License Required Dependancy None iDRAC.APSTable This group contains the attributes that provides details about APS table. iDRAC.APSTable.vDiskSetup (Read or Write) Description Specifies the APS vDisk Store setup configuration. Legal Values ● String of up to 64 ASCII characters. Default Value 01 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ASRConfig This group contains the attributes that provides details about ASR configuration. iDRAC.ASRConfig.
Dependancy None iDRAC.Autodiscovery.EnableIPChangeAnnounceFromDHCP (Read or Write) Description Enable iDRAC to obtain list of consoles through DHCP. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Autodiscovery.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Autodiscovery.UnsolicitedIPChangeAnnounceRate (Read or Write) Description Rate of periodic refresh of IP address to consoles Legal Values ● ● ● ● ● ● ● ● ● ● Default Value 4 Write Privilege Configure iDRAC Disabled-0 1 hour-1 6 hours-2 12 hours-3 1 day-4 3 days-5 1 week-6 2 weeks-7 4 weeks-8 6 weeks-9 License Required iDRAC Basic Dependancy None iDRAC.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.BootstrapUsers This group contains the attributes that provides details about Bootstrap Users. iDRAC.BootstrapUsers.Password (Read Only) Description Password of the temporary Bootstrap account Legal Values ● String of up to 16 ASCII characters. Default Value None Write Privilege License Required Dependancy None iDRAC.BootstrapUsers.
iDRAC.CMCSNMPAlert.AlertPort (Read or Write) Description Specifies Alert Port number Legal Values ● Integral values from 1 to 65535 Default Value 162 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.CMCSNMPAlert.CommunityName (Read or Write) Description Specifies Community name Legal Values ● String of up to 18 ASCII characters. Default Value public Write Privilege Configure iDRAC License Required Dependancy None iDRAC.CMCSNMPAlert.
iDRAC.CMCSNMPTrapIPv6.DestIPv6Address (Read or Write) Description Specifies Trap IPV6 destination address Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.CMCSNMPTrapIPv6.State (Read or Write) Description Enable or Disable SNMP Trap IPV6 State Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.ConsumerNotify.
iDRAC.CPUConfig.HostResetOnIERR (Read or Write) Description 1: Reset host after collection done on IERR, 0: No host reset after collection done on IERR. Legal Values ● False-0 ● True-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPV4 This group contains the attributes that provides details about iDRAC.CurrentIPV4. iDRAC.CurrentIPv4.
iDRAC.CurrentIPv4.DNS2 (Read Only) Description IPv4 address for DNS Server 2 Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv4.DNS3 (Read Only) Description IPv4 address for DNS Server 3 Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv4.
● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv4.Gateway (Read Only) Description The gateway for the iDRAC IPv4 address Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv4.
Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Address11 (Read Only) Description iDRAC IPv6 eleventh address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Address12 (Read Only) Description iDRAC IPv6 twelfth address Legal Values ● String of up to 63 ASCII characters.
iDRAC.CurrentIPv6.Address15 (Read Only) Description iDRAC IPv6 fifteenth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Address2 (Read Only) Description iDRAC IPv6 second address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Address6 (Read Only) Description iDRAC IPv6 sixth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Address7 (Read Only) Description iDRAC IPv6 seventh address Legal Values ● String of up to 63 ASCII characters.
iDRAC.CurrentIPv6.AddressGenerationMode (Read Only) Description IPv6 Address Generation Mode Legal Values ● StablePrivacy-0 ● EUI64-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.AutoConfig (Read Only) Description Enables or Disables the iDRAC IPv6 auto configuration option Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.
Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.DNS3 (Read Only) Description IPv6 DNS Server 3 Address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.
License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.Gateway (Read Only) Description iDRAC IPv6 Gateway Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6.
iDRAC.CurrentIPv6Router This group contains the attributes that provide details about current IPv6 router. iDRAC.CurrentIPv6Router.Address (Read or Write) Description IPv6 Router Address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentIPv6Router.MACAddress (Read or Write) Description IPv6 Route MAC Address Legal Values ● String of up to 17 ASCII characters.
iDRAC.CurrentNIC This group contains the attributes that provide details about current NIC. iDRAC.CurrentNIC.ActiveNIC (Read Only) Description Currently Active iDRAC network interface Legal Values ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Default Value 1 Write Privilege Configure iDRAC None-0 Dedicated-1 LOM1-2 LOM2-3 LOM3-4 LOM4-5 LOM5-6 LOM6-7 LOM7-8 LOM8-9 LOM9-10 LOM10-11 LOM11-12 LOM12-13 LOM13-14 LOM14-15 LOM15-16 LOM16-17 License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.AutoDetect (Read Only) Description Enable or disable auto detection feature of iDRAC Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
Dependancy None iDRAC.CurrentNIC.DNSDomainName (Read Only) Description The DNS Domain Name Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.DNSRacName (Read Only) Description The iDRAC name, which is iDRAC-<SVCTAG> by default Legal Values ● String of up to 63 ASCII characters.
iDRAC.CurrentNIC.Enable (Read Only) Description Enables or Disables the iDRAC network interface controller. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.FactoryMAC (Read Only) Description The MAC Address of the iDRAC Legal Values ● String of up to 17 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
iDRAC.CurrentNIC.LinkStatus (Read Only) Description iDRAC Link Status. Legal Values ● No-0 ● Yes-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.MACAddress (Read Only) Description The MAC Address of the iDRAC Legal Values ● String of up to 17 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
Default Value 1500 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.NICInterface2NCSIPortCount (Read or Write) Description Eth2 NCSI Port Count Legal Values ● Integral values from 0 to 64 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
iDRAC.CurrentNIC.NumberOfLOM (Read Only) Description Number of shared LOM available for iDRAC network interface Legal Values ● Integral values from 0 to 16 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.PendingActiveNIC (Read or Write) Description Pending Active NIC Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
iDRAC.CurrentNIC.SharedNICScanTime (Read Only) Description Dedicated to Shared Failover Timeout Legal Values ● Integral values from 5 to 255 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
Dependancy None iDRAC.CurrentNIC.VLanPriority (Read Only) Description Specifies the VLAN priority for the network VLAN configuration Legal Values ● Integral values from 0 to 7 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.CurrentNIC.
iDRAC.DCMIThermal This group contains the attributes that provide details about DCMI thermal settings. iDRAC.DCMIThermal.DCMIControl (Read or Write) Description DCMI Control Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCMIThermal.
License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.BackplaneCable0ErrorMask (Read or Write) Description Backplane Cable0 Error Mask Legal Values ● Integral values from 0 to 1048575 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.
iDRAC.DCSCustom.DisableFRUProductAreaOverwrite (Read or Write) Description Indicates the presence of ID Module to disable FRU Product Area overwrite. Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.EnableDNS3 (Read or Write) Description Enables or disables the DNS3 option for IPv4 and IPv6.
iDRAC.DCSCustom.NDCPresent (Read or Write) Description Indicates the presence or absence of Network Daughter Card. Legal Values ● Absent-0 ● Present-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.NonDellSplitBPSupport (Read or Write) Description Split Back Plane Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.
iDRAC.DCSCustom.SdrMultiplierEnable (Read or Write) Description Indicates the presence of ID Module for changing SDR Multiplier. Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSCustom.SdrMultiplierValue (Read or Write) Description Indicates the value of SDR Multiplier.
iDRAC.DCSResetCtlr This group contains the attributes that provide details about DCS reset control. iDRAC.DCSResetCtlr.DCSCtlr1Reset (Read or Write) Description DCS Control1 Reset Legal Values ● String of up to ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DCSResetCtlr.DCSCtlr1Status (Read or Write) Description DCS Control1 Status Legal Values ● String of up to ASCII characters.
iDRAC.DCSResetCtlr.DCSCtlrSync (Read or Write) Description DCS Control Sync Legal Values ● String of up to ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.DefaultCredentialMitigationConfigGroup NOTE: The iDRAC.Tuning group is deprecated and replaced with iDRAC.DefaultCredentialMitigationConfigGroup group. This group contains the attributes that provide details about iDRAC Default Credential Mitigation Configuration Group.
Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.DelegatedAuth.Name (Read or Write) Description Name 'tag' for the Delegated authentication, used for configuration Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.DelegatedAuth.
Legal Values ● Integral values from 1 to 60 Default Value 10 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.DelegatedAuthConfig.AuthServerTransferTimeout (Read or Write) Description The maxium time in seconds allowed to perform the HTTP GET request of the ServerURL and jwks_url Legal Values ● Integral values from 1 to 600 Default Value 30 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.DelegatedAuthConfig.
iDRAC.EmailAlert.Address (Read or Write) Description Specifies the destination email address for email alerts Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.EmailAlert.CustomMsg (Read or Write) Description Specifies the custom message that forms the subject of the alert Legal Values ● String of up to 32 ASCII characters.
iDRAC.GpGPUTable.CoolingType (Read or Write) Description Indicates Cooling Type as Active or Passive Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.DellValidated (Read or Write) Description Provides Dell Validated value Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.FreshAirCompliance (Read or Write) Description Provides Fresh Air Compliance value Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
iDRAC.GpGPUTable.IsEmptyEntry (Read or Write) Description Indicates if a particular entry is empty or not. Legal Values ● False-0 ● True-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.MinLFM (Read or Write) Description Provides Min LFM Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.SVid (Read or Write) Description Provides SubVendor Id Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
iDRAC.GpGPUTable.ThermalTarget2 (Read or Write) Description Indicates Thermal Target 2 Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.ThrottledPower (Read or Write) Description Provides Throttled Power Value Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.TSAddressC (Read or Write) Description Indicates TS Address C Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
iDRAC.GpGPUTable.TSOffsetC (Read or Write) Description Indicates TS Offset C Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.TSOffsetD (Read or Write) Description Indicates TS Offset D Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.GpGPUTable.
iDRAC.GroupManager.CloneFWStatus (Read or Write) Description Specifies the firmware clone status. Legal Values ● Disabled-0 ● Enabled-1 ● Complete-2 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.CloneStatus (Read or Write) Description Configuration Clone Status Legal Values ● Disabled-0 ● Enabled-1 ● Complete-2 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.
iDRAC.GroupManager.DwnldShareTimeout (Read or Write) Description Specifies the download host share timeout in seconds. The share shall be unavailable after this duration. Legal Values ● Integral values from 0 to 65535 Default Value 900 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.GroupingUser (Read Only) Description Grouping User Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.GroupName (Read Only) Description GroupName is the user specified name of the iDRAC Group Manager local group. Legal Values ● String of up to 32 ASCII characters.
iDRAC.GroupManager.GroupPublishInterval (Read or Write) Description Group Manager Group Existence Publish Interval Legal Values ● Integral values from 0 to 86400 Default Value 86400 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.GroupTaskAutoRetryCount (Read or Write) Description Group Task Auto Retry Count Legal Values ● Integral values from 0 to 65535 Default Value 10 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.
iDRAC.GroupManager.MaxConDwnldsPerHost (Read or Write) Description Specifies the maximum concurrent downloads allowed from a download host. Legal Values ● Integral values from 0 to 65535 Default Value 6 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.
Default Value 50 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.MaxTotDwnldsPerHost (Read or Write) Description Specifies the maximum total downloads allowed from a download host. Legal Values ● Integral values from 0 to 65535 Default Value 36 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.
iDRAC.GroupManager.PrimaryDiscoveryWaitDuration (Read or Write) Description Wait Duration for Existing Controller Before Election Legal Values ● Integral values from 120 to 65535 Default Value 120 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.
iDRAC.GroupManager.ServicePublishInterval (Read or Write) Description Group Manager Service Capability Publish Interval Legal Values ● Integral values from 0 to 86400 Default Value 86400 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.GroupManager.Status (Read or Write) Description Enables or disables Group Management. iDRAC Group Manager feature offers simplified basic management of iDRACs on the same local network using the iDRAC GUI.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.BIOSSignIIBFailure (Read or Write) Description This holds BIOS Feature Bits Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.Build (Read Only) Description String containing the current product build version Legal Values ● String of up to 16 ASCII characters.
Dependancy None iDRAC.Info.HWRev (Read Only) Description Specifies the iDRAC hardware revision. Legal Values ● String of up to 256 ASCII characters. Default Value .0.1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.IPMIVersion (Read Only) Description Current IPMI Version supported on iDRAC Legal Values ● String of up to 20 ASCII characters. Default Value 2.0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.
Legal Values ● String of up to ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.MinVersion (Read Only) Description Specifies the iDRAC minor version. Legal Values ● String of up to ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.
iDRAC.Info.RollbackBuild (Read Only) Description Specifies the iDRAC rollback build number. Legal Values ● String of up to 256 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Info.RollbackLCBuild (Read Only) Description Specifies the Lifecycle Controller rollback build number. Legal Values ● String of up to ASCII characters.
Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.Info.RollbackPDSVersion (Read Only) Description Rollback PDS Version Legal Values ● String of up to ASCII characters. Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.Info.RollbackVersion (Read Only) Description Specifies the iDRAC rollback version. Legal Values ● String of up to 256 ASCII characters.
iDRAC.Info.Type (Read Only) Description Identifies the remote access controller type as iDRAC Legal Values ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Default Value 1 Write Privilege Configure iDRAC 12G/13G/14G/15G-0 Other-1 Unknown-2 12G Monolithic-16 12G Modular-17 13G Monolithic-32 13G Modular-33 12G DCS-21 13G DCS-34 14G Monolithic-48 14G Modular-49 14G DCS-50 15G Monolithic-64 15G Modular-65 15G DCS-66 License Required iDRAC Basic Dependancy None iDRAC.Info.
iDRAC.IntegratedDatacenter.Eject (Read or Write) Description Eject Server from Integrated Data Center Legal Values ● No ● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IntegratedDatacenter.OperationMode (Read Only) Description Current Mode Legal Values ● Default● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IntegratedDatacenter.
iDRAC.InventoryHash This group contains the attributes that provide details about Inventory Hash. iDRAC.InventoryHash.HashCalculationInterval (Read or Write) Description Set hash value generation interval Legal Values ● Integral values from 15 to 1440 Default Value 15 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.InventoryHash.HWInventoryHash (Read Only) Description Provides hash value for available hardware inventory.
iDRac.IOIDOpt This group contains the attributes that provides details about iDRAC IOIDOpt. iDRAC.IOIDOpt.InitiatorPersistencePolicy (Read or Write) Description Initiator Persistence Policy Legal Values ● ● ● ● ● ● ● ● Default Value 7 Write Privilege Configure iDRAC None-0 WarmReset-1 ColdReset-2 WarmReset, ColdReset-3 ACPowerLoss-4 WarmReset, ACPowerLoss-5 ColdReset, ACPowerLoss-6 WarmReset, ColdReset, ACPowerLoss-7 License Required iDRAC Basic Dependancy None iDRAC.IOIDOpt.
Legal Values ● ● ● ● ● ● ● ● Default Value 7 Write Privilege Configure iDRAC None-0 WarmReset-1 ColdReset-2 WarmReset, ColdReset-3 ACPowerLoss-4 WarmReset, ACPowerLoss-5 ColdReset, ACPowerLoss-6 WarmReset, ColdReset, ACPowerLoss-7 License Required iDRAC Basic Dependancy None iDRAC.IOIDOpt.
iDRAC.IPBlocking This group contains the attributes that provides details about IP Blocking. iDRAC.IPBlocking.BlockEnable (Read or Write) Description Enables or disables the IPv4 address blocking feature of iDRAC. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.
iDRAC.IPBlocking.RangeAddr (Read or Write) Description Specifies the IPv4 address of IPv4 Address Range 1 of the IP blocking feature of iDRAC. Legal Values ● String of up to 16 ASCII characters. Default Value 192.168.1.1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.RangeAddr2 (Read or Write) Description Specifies the IPv4 address of IPv4 Address Range 2 of the IP blocking feature of iDRAC. Legal Values ● String of up to 16 ASCII characters.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.RangeEnable (Read or Write) Description Enables or disables IPv4 Address Range 1 of the IP blocking feature of iDRAC. t Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.RangeEnable2 (Read or Write) Description Enables or disables IPv4 Address Range 2 of the IP blocking feature of iDRAC.
Dependancy None iDRAC.IPBlocking.RangeEnable5 (Read or Write) Description Enables or disables IPv4 Address Range 5 of the IP blocking feature of iDRAC. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.RangeMask (Read or Write) Description Specifies the IPv4 subnet mask of IPv4 Address Range 1 of the IP blocking feature of iDRAC. Legal Values ● String of up to 16 ASCII characters. Default Value 255.255.
iDRAC.IPBlocking.RangeMask4 (Read or Write) Description Specifies the IPv4 subnet mask of IPv4 Address Range 4 of the IP blocking feature of iDRAC. Legal Values ● String of up to 16 ASCII characters. Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPBlocking.RangeMask5 (Read or Write) Description Specifies the IPv4 subnet mask of IPv4 Address Range 5 of the IP blocking feature of iDRAC. Legal Values ● String of up to 16 ASCII characters.
Default Value 00000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIFireWallChannel This group contains the attributes that provide details about IPMI Firewall Channel. iDRAC.IPMIFireWallChannel.ChannelEnableCommand (Read or Write) Description Channel enable Legal Values ● String of up to 14 ASCII characters. Default Value 11111111111111 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.IPMIIPConfig.ArpControl (Read or Write) Description BMC-generated ARP control parameter. Check IPMI specification for more info. Legal Values ● String of up to 2 ASCII characters. Default Value 02 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIIPConfig.ArpInterval (Read or Write) Description Gratuitous ARP interval Legal Values ● String of up to 2 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIIPConfig.IPHeader (Read or Write) Description IPMI configuration for RMCP IPV4 header parameter. Check IPMI specification for more info Legal Values ● String of up to 6 ASCII characters. Default Value 404010 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMILan This group contains the attributes that provides details about iDRAC IPMI Lan. iDRAC.IPMILan.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMILan.EncryptionKey (Read or Write) Description Specifies the IPMI Encryption key Legal Values ● String of up to 40 ASCII characters. Default Value 0000000000000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMILan.
iDRAC.IPMILANConfig.CipherSuitePrivilege (Read or Write) Description Cipher suite privilege Legal Values ● String of up to 22 ASCII characters. Default Value 0040444444444444444444 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMILANConfig.SecurityKeyKR (Read or Write) Description Security key Legal Values ● String of up to 42 ASCII characters.
iDRAC.IPMIPefOften.BMCRecordID (Read or Write) Description BMC record ID Legal Values ● Integral values from 0 to 65535 Default Value 65535 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIPefOften.SoftwareRecordID (Read or Write) Description Software record ID Legal Values ● Integral values from 0 to 65535 Default Value 65535 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIPefSeldom.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIPefSeldom.PEFAlertDefaultsSet (Read or Write) Description PEF Alert Defaults Set Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIPefSeldom.
iDRAC.IPMIPefSeldomAlerts.AlertEntry (Read or Write) Description Alert entry Legal Values ● String of up to 6 ASCII characters. Default Value 000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIPefSeldomAlerts.AlertStringEntry (Read or Write) Description Alert string entry Legal Values ● String of up to 100 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISDR.SDRDelTimeStamp (Read or Write) Description SDR delete time stamp Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISEL.SELdata (Read or Write) Description SEL data Legal Values ● String of up to 20 ASCII characters.
iDRAC.IPMISerial.ChannelAccess (Read or Write) Description Channel access Legal Values ● Integral values from 0 to 63 Default Value 58 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.EchoControl (Read or Write) Description Enables or Disables echo control on the IPMI serial interface Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.
Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.IsGroupInstanceValid (Read or Write) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.LastMux (Read or Write) Description Specifies the last serial mux setting.
iDRAC.IPMISerial.NewLineSeq (Read or Write) Description Specifies the new line sequence for the IPMI serial interface Legal Values ● ● ● ● ● ● Default Value 1 Write Privilege Configure iDRAC None-0 CR-LF-1 NULL-2 CR-3 LF-CR-4 LF-5 License Required iDRAC Basic Dependancy None iDRAC.IPMISerial.
iDRAC.IPMISystemParameter.ControllerIPMBAddress (Read or Write) Description Controller IPMB address Legal Values ● String of up to 2 ASCII characters. Default Value 20 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISystemParameter.DeviceGUID (Read or Write) Description Device GUID Legal Values ● String of up to 32 ASCII characters.
Default Value 0000000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIUserEncryptIVKey.PWDIVKey2 (Read or Write) Description PWD IV key2 Legal Values ● String of up to 34 ASCII characters. Default Value 0000000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMIUserInfo.
iDRAC.IPMIUserInfo.UserChannelAccess (Read or Write) Description User Channel access Legal Values ● String of up to 16 ASCII characters. Default Value 0000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISOL This group contains the attributes that provides details about iDRAC IPMI SOL. iDRAC.IPMISOL.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISOL.Enable (Read or Write) Description Enables or disables Serial Over LAN (SOL) Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPMISOL.
iDRAC.IPMISOL.SendThreshold (Read or Write) Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sending an SOL data packet Legal Values ● Integral values from 1 to 255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4 This group contains the attributes that provides details about iDRAC IPv4 settings. iDRAC.IPv4.
iDRAC.IPv4.DNS2 (Read or Write) Description IPv4 address for DNS Server 2 Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4.DNS3 (Read or Write) Description IPv4 address for DNS Server 3 Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4.
Legal Values ● String of up to 16 ASCII characters. Default Value 192.168.0.1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4.Netmask (Read or Write) Description The subnet mask used for the iDRAC IPv4 address Legal Values ● String of up to 16 ASCII characters. Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPV4Static This group contains the attributes that provides details about iDRAC.
Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4Static.DNS3 (Read or Write) Description Statically configurable DNS Server 3 Legal Values ● String of up to 16 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv4Static.DNSFromDHCP (Read or Write) Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network.
iDRAC.IPV6 This group contains the attributes that provides details about iDRAC IPv6 settings iDRAC.IPv6.Address1 (Read or Write) Description iDRAC IPv6 Address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.Address10 (Read Only) Description iDRAC IPv6 tenth address Legal Values ● String of up to 63 ASCII characters.
iDRAC.IPv6.Address13 (Read Only) Description iDRAC IPv6 thirteenth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.Address14 (Read Only) Description iDRAC IPv6 fourteenth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.Address4 (Read Only) Description iDRAC IPv6 fourth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.Address5 (Read Only) Description iDRAC IPv6 fifth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.
iDRAC.IPv6.Address8 (Read Only) Description iDRAC IPv6 eighth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.Address9 (Read Only) Description iDRAC IPv6 ninth address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.
iDRAC.IPv6.AutoConfig (Read or Write) Description Enables or Disables the iDRAC IPv6 auto configuration option Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.DNS1 (Read or Write) Description IPv6 DNS Server 1 Address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.
● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.DUID (Read Only) Description DHCP Unique Identifier Legal Values ● String of up to 144 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6.
Dependancy None iDRAC.IPv6.IPV6NumOfExtAddress (Read Only) Description Total number of extended IP Legal Values ● Integral values from 0 to 255 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.LinkLocalAddress (Read Only) Description iDRAC IPv6 Link Local Address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required Dependancy None iDRAC.IPv6.
iDRAC.IPv6Static.Address1 (Read or Write) Description iDRAC static IPv6 address Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.DNS1 (Read or Write) Description Statically configurable DNS Server 1 Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.Gateway (Read or Write) Description iDRAC static IPv6 gateway Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.
iDRAC.IPv6Static.Router1PrefixLength (Read or Write) Description Specifies the iDRAC static IPv6 Router 1 prefix length. Legal Values ● Integral values from 0 to 128 Default Value 64 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.Router1PrefixValue (Read or Write) Description Specifies the iDRAC static IPv6 Router 1 prefix value. Legal Values ● String of up to 63 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.Router2PrefixValue (Read or Write) Description Specifies the iDRAC static IPv6 Router 2 prefix value. Legal Values ● String of up to 63 ASCII characters. Default Value :: Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.IPv6Static.RouterAddressConfigControl (Read or Write) Description Specifies the iDRAC static IPV6 Router configuration control.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.iSMExtensions.OEMIDLMEState (Read Only) Description The following attribute is defined to be set by PM to control the enablement of the complete feature in the required personality of the server. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Not Applicable License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.KMS.iDRACUserName (Read or Write) Description Specifies the User Id on the Key Management server for this iDRAC. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.KMIPPortNumber (Read or Write) Description Specifies the KMIP Port Number for the Primary and Redundant Key Management Server.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.ProxyPortNumber (Read or Write) Description Specifies the Port Number for the Proxy Server to be used by iDRAC to connect to the Key Management server. Legal Values ● Integral values from 0 to 65535 Default Value 5696 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.
iDRAC.KMS.RedundantServerAddress2 (Read or Write) Description Specifies the FQDN, IPv4 address or IPv6 address of the second Redundant Key Management Server. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.RedundantServerAddress3 (Read or Write) Description Specifies the FQDN, IPv4 address or IPv6 address of the third Redundant Key Management Server.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.RedundantServerAddress7 (Read or Write) Description Specifies the FQDN, IPv4 address or IPv6 address of the seventh Redundant Key Management Server. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.
iDRAC.KMS.Timeout (Read or Write) Description Specifies the SSL connection timeout value in seconds. Legal Values ● Integral values from 0 to 300 Default Value 10 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.KMS.UseProxyToConnect (Read or Write) Description Indicates to iDRAC to use a Proxy to connect to the Key Management server. Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.
iDRAC.LDAP.BindPassword (Read or Write) Description A bind password to use in conjunction with the bindDN. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAP.CertValidationEnable (Read or Write) Description Controls certificate validation during SSL handshake. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAP.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAP.Port (Read or Write) Description Port of LDAP over SSL. Legal Values ● Integral values from 1 to 65535 Default Value 636 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAP.RSASecurID2FALDAP (Read or Write) Description Enables or disables RSA SecurID 2 Factor Authentication for LDAP users.
License Required Dependancy None iDRAC.LDAP.ServerCachePath (Read Only) Description Server Cache Path Legal Values ● String of up to ASCII characters. Default Value /run/ldap/ldap_server_cache Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAP.UserAttribute (Read or Write) Description Specifies the user attribute to search for. Legal Values ● String of up to 254 ASCII characters.
Dependancy None iDRAC.LDAPRoleGroup.DN (Read or Write) Description This is the Domain Name of the group. Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAPRoleGroup.DN.1 (Read or Write) Description This is the Domain Name of the group. Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.
Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAPRoleGroup.DN.5 (Read or Write) Description This is the Domain Name of the group. Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.LDAPRoleGroup.
Write Privilege Not Applicable License Required iDRAC Basic Dependancy None iDRAC.LDAPRoleGroup This group contains the attributes that provides details about iDRAC Live Scanning group. iDRAC.LiveScanning.BIOSScanningFrequency (Read Only) Description Indicates Live Scan frequency Legal Values ● ● ● ● ● ● Default Value 0 Write Privilege Configure iDRAC Never-0 Now-1 Daily-2 Weekly-3 Monthly-4 Yearly-5 License Required Dependancy None iDRAC.LiveScanning.
iDRAC.LocalSecurity This group contains the attributes that provides details about iDRAC local security. iDRAC.LocalSecurity.PrebootConfig (Read or Write) Description Enables or disables the ability of the local user to configure iDRAC from the BIOS POST option-ROM. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Lockdown This group contains the attributes that provides details about iDRAC lockdown. iDRAC.
iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Description Enable SEL OEM Event Filter Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Logging.SetSELTimeBlock (Read or Write) Description Indicate blocking to check seting SEL time. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
License Required iDRAC Basic Dependancy None iDRAC.MgmtNetworkInterface.LinkStatus (Read or Write) Description Link Status Legal Values ● ● ● ● Default Value 2 Write Privilege Configure iDRAC Unknown-0 LinkUp-1 NoLink-2 LinkDown-3 License Required iDRAC Basic Dependancy None iDRAC.MgmtNetworkInterface.MacAddress (Read or Write) Description MAC Address Legal Values ● String of up to 17 ASCII characters.
iDRAC.NIC This group contains the attributes that provides details about iDRAC NIC. iDRAC.NIC.AEMAPresentStatus (Read or Write) Description The status of AMEA present. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.AMEAPresentStatus12G (Read or Write) Description The status of 12G AMEA present.
License Required Dependancy None iDRAC.NIC.AutoConfigIPV6 (Read Only) Description IPV6 Enable Auto Configuration Legal Values ● Disabled-0 ● Enable Once-1 ● Enable Once After Reset-2 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.AutoDedicatedNIC (Read or Write) Description Enable Auto NIC Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
Dependancy None iDRAC.NIC.CMCResetState (Read or Write) Description CMC Reset State Legal Values ● Reset-0 ● Failover-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.ConfigChangedByUser (Read or Write) Description Network Configuration Changed by User Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
iDRAC.NIC.d9netsettingstate (Read or Write) Description d9net setting state Legal Values ● Idle-0 ● InProgress-1 ● Completed-2 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.d9netusbsettingstate (Read or Write) Description d9net USB setting state Legal Values ● ● ● ● Default Value 0 Write Privilege Configure iDRAC Idle-0 InProgress-1 Completed-2 Initialized-3 License Required iDRAC Basic Dependancy None iDRAC.NIC.
iDRAC.NIC.DCMIDHCPopt60opt43 (Read or Write) Description DCMI DHCP opt60 opt43 Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.DCMIDHCPpkttimeout (Read or Write) Description DCMI DHCP packet timeout Legal Values ● Integral values from to Default Value 4 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
Legal Values ● Integral values from to Default Value 64 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.DedicatedNICScanTime (Read or Write) Description Wait time for the iDRAC to switch from dedicated mode to shared mode. Legal Values ● Integral values from 5 to 255 Default Value 5 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NIC.DiscoveryLLDP (Read or Write) Description Enables LLDP over active NIC Interface.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.DNSDomainNameFromDHCP (Read or Write) Description Specifies that the iDRAC DNS Domain Name should be assigned from the network DHCP server. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NIC.
iDRAC.NIC.DummySwitchConnection (Read or Write) Description Specifies the Chassis ID extracted from LLDP packet Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.DummySwitchPortConnection (Read or Write) Description Specifies the Port ID extracted from LLDP packet. Legal Values ● String of up to 512 ASCII characters.
● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.Failover (Read or Write) Description Specifies the NIC Failover LOM. Legal Values ● ● ● ● ● ● Default Value 0 Write Privilege Configure iDRAC None-0 LOM1-1 LOM2-2 LOM3-3 LOM4-4 All-5 License Required iDRAC Basic Dependancy None iDRAC.NIC.FailoverFQDD (Read Only) Description FQDD failover Legal Values ● String of up to 512 ASCII characters. Default Value None;NIC.
● completed-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.G5KxcablePresence (Read or Write) Description G5Kx cable Presence Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.MACAddress (Read Only) Description The MAC Address of the iDRAC Legal Values ● String of up to 17 ASCII characters.
License Required iDRAC Basic Dependancy None iDRAC.NIC.ModularLinkstatus (Read or Write) Description iDRAC Link Status from Chassis Management Controller Legal Values ● No-0 ● Yes-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
Dependancy None iDRAC.NIC.PingEnable (Read or Write) Description Enables iDRAC to respond to pings Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.PowerOnOCPSlot1InS5 (Read or Write) Description Enable Embedded Networking OCP slot 1 power in host off / S5 state for Wake On LAN.
Dependancy None iDRAC.NIC.SelectionFQDD (Read Only) Description FQDD selection Legal Values ● String of up to 512 ASCII characters. Default Value Dedicated;NIC.Integrated.1-1-1;NIC.Integrated.1-2-1;NIC.Integrated.1-3-1;NIC.Integrated.1-4-1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
iDRAC.NIC.Speed (Read or Write) Description Specifies the speed for the iDRAC NIC Legal Values ● ● ● ● ● ● ● ● ● ● Default Value 1 Write Privilege Configure iDRAC 10-0 100-1 1000-2 2500-3 10000-4 20000-5 25000-6 40000-7 50000-8 100000-9 License Required iDRAC Basic Dependancy None iDRAC.NIC.SwitchConnection (Read Only) Description Specifies the Chassis ID extracted from LLDP packet Legal Values ● String of up to 512 ASCII characters.
Dependancy None iDRAC.NIC.VLanEnable (Read or Write) Description Enables or Disables the VLAN capabilities of the iDRAC Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NIC.
iDRAC.NIC.VLanSetting (Read or Write) Description Auto VLAN Setting Legal Values ● Both Enable-0 ● Disabled on Dedicated-1 ● Disabled on share-2 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.NICStatic This group contains the attributes that provides details about iDRAC NIC static.
iDRAC.NonSDLPlugins This group contains the attributes that provide details about non SDL plugins. iDRAC.NonSDLPlugins.PluginName (Read Only) Description Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Not Applicable License Required iDRAC Basic Dependancy None iDRAC.NonSDLPlugins.
iDRAC.NTPConfigGroup This group contains the attributes that provides details about iDRAC NTP Config group. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Description Name of NTP Server 1 Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NTPConfigGroup.NTP1SecurityKey (Read or Write) Description Security Key for NTP Server 1 Legal Values ● String of up to 64 ASCII characters.
iDRAC.NTPConfigGroup.NTP2 (Read or Write) Description Name of NTP Server 2 Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NTPConfigGroup.NTP2SecurityKey (Read or Write) Description Security Key for NTP Server 2 Legal Values ● String of up to 64 ASCII characters. Default Value “” Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NTPConfigGroup.
Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NTPConfigGroup.NTP3SecurityKey (Read or Write) Description Security Key for NTP Server 3 Legal Values ● String of up to 64 ASCII characters. Default Value “” Write Privilege Configure iDRAC License Required Dependancy None iDRAC.NTPConfigGroup.
License Required Dependancy None iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write) Description NTP Maximum Distance Legal Values ● Integral values from 1 to 128 Default Value 16 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.OCPInformation This group contains the attributes that provide details about OCP information. iDRAC.OCPInformation.
License Required iDRAC Basic Dependancy None iDRAC.OCPInformation.PCISVID (Read or Write) Description Specifies the PCI SVID of OCP Card Legal Values ● Integral values from 0 to 65535 Default Value 32902 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.OCPInformation.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.OS-BMC.IdracPTEpIpAddr (Read or Write) Description IDRAC PTE IP Address Legal Values ● String of up to 16 ASCII characters. Default Value 169.254.0.1 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.OS-BMC.OsIpAddress (Read or Write) Description OS-BMC Passthrough Host IP Address. Enter a valid IPv4 address.
Dependancy None iDRAC.OS-BMC.PTMode (Read or Write) Description Specifies the OS-BMC Passthrough mode. Note: Starting in iDRAC9 4.00, lom-p2p is not supported when NIC Selection is set to Dedicated. Legal Values ● lom-p2p-0 ● usb-p2p-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy OS-BMC.PTCompatibility must be set to Capable. iDRAC.OS-BMC.UsbNicIpAddress (Read or Write) Description Specifies the USB NIC IP Address. Enter a valid IPv4 address.
iDRAC.OS-BMC.UsbNicLcuiNatRouting (Read or Write) Description Specifies the USB-NIC NAT Routing Control for LCUI. Legal Values ● Disabled/Failed-0 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.OS-BMC.UsbNicULA (Read or Write) Description Specifies the USB-NIC IPv6 unique local address.
Dependancy None iDRAC.Platformcapability This group contains the attributes that provides details about iDRAC Platform capability. iDRAC.PlatformCapability.12GBackplaneon13GCapable (Read Only) Description Indicates hardware is 12G Backplane on 13G capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.ASHRAECapable (Read Only) Description Indicates if system is ASHRAE capable.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.BluetoothCapable (Read Only) Description Indicates hardware is Bluetooth capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Dependancy None iDRAC.PlatformCapability.DPCapable (Read or Write) Description Digital port Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.FixedInputBulkVoltageCapable (Read Only) Description Indicates if the platform is capable of supporting Fixed Input Bulk Voltage.
iDRAC.PlatformCapability.FrontPanelUSBCapable (Read Only) Description Indicates hardware is Front Panel USB capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.FrontPortUSBConfiguration (Read Only) Description When BIOS is configured as "All Ports Off (Dynamic)" the above capability attribute will be set to true, otherwise false.
iDRAC.PlatformCapability.GridCurrentCapCapable (Read Only) Description System current cap capability Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
iDRAC.PlatformCapability.LCDCapable (Read Only) Description Indicates platform is LCD capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.LicenseUpsellCapable (Read Only) Description Indicates hardware is License upsell capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.PlatformCapability.LiveScanCapable (Read Only) Description Indicates if Live Scan is supported. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.ModularSharedLOMCapable (Read Only) Description Indicates hardware is Modular Shared LOM Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.NMPTASCapable (Read Only) Description Indicates hardware is NM PTAS Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.OCPMezzSupport (Read Only) Description Determine whether to check for OCP MUX and set the OCP Card Active attribute accordingly. Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.PostPoneNICSelectionCapable (Read Only) Description Delay Application of NIC Selection Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.PowerInventoryCapable (Read or Write) Description Indicates Power Inventory Support Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.PSURedundancyCapable (Read or Write) Description Indicates PSU Redundancy Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.SCPwrMonitoringCapable (Read Only) Description Indicates hardware is SC Pwr Monitoring Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Dependancy None iDRAC.PlatformCapability.SmartCardLoginCapable (Read Only) Description Indicates hardware is Smart Card Login Capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
Dependancy None iDRAC.PlatformCapability.ThermalManagementCapable (Read Only) Description Indicates hardware is thermal management capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.UnsupportedCntlrMsgCapable (Read Only) Description Indicates if platform needs softer message for unsupported controller detection or not.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.vFlashCapable (Read Only) Description Indicates hardware is vFlash capable Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PlatformCapability.
● 0x0800-2 ● 0x0400-3 ● 0x0200-4 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing This group contains the attributes that provides details about iDRAC PM licensing. iDRAC.PMLicensing.DataVersion (Read or Write) Description This is for 13G group 20050 Legal Values ● String of up to 255 ASCII characters. Default Value ff Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-15gThermal (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-AlertHostUsbInsertion (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-AVOTON-4CORE (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-AVOTON-8CORE (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-BASIC-REMOTE-INVENTORY-EXPORT (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-BMC-PLUS (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Dependancy None iDRAC.PMLicensing.LM-CONSOLE-COLLABORATION (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-DCS-GUI (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-DHCP-CONFIGURE (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-EKMS-FEATURE (Read or Write) Description This is for EKMS feature Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-GPUMonitoring (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-IDRAC-EXPRESS (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-LAST-CRASH-SCREEN-CAPTURE (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-LICENSE-UI (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-LOCKDOWN-MODE (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-OOB (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-PART-REPLACEMENT (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-QUALITY-BANDWIDTH-CONTROL (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-RACADM-CLI (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-REMOTE-CONFIGURATION (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-REMOTE-SYSLOG (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-SCEP (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-SECURITY-LOCKOUT (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-Simple-2FA (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-SmartLogs (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-SSH (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-SSH-PK-AUTHEN (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-Telemetry (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-Telemetry-Basic (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-TWO-FACTOR-AUTHEN (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-UPDATE-FROM-REPO (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-USC-EMBEDDED-DIAGNOSTICS (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-VFOLDER (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
iDRAC.PMLicensing.LM-VNC (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.LM-WSMAN (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 ● 0xFF-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PMLicensing.PMDrivenLicensing (Read or Write) Description This is for 13G group 20050 Legal Values ● 0-0 ● 1-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore This group contains the attributes that provide details about private store. iDRAC.PrivateStore.
● True-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.BladeAllocatedPwr (Read or Write) Description Blade Allocated Power Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
iDRAC.PrivateStore.BladeBIOSRuntimeMin (Read or Write) Description Blade BIOS Runtime Min Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.BladeCPUNormalPwr (Read or Write) Description Blade CPU Normal Power Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.BladeHDDThrottlePwr (Read or Write) Description Blade HDD Throttle Power Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
iDRAC.PrivateStore.BladeMezzThrottlePwr (Read or Write) Description Blade Mezz Throttle Power Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.BladeNDCNormalPwr (Read or Write) Description Blade NDC Normal Power Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.BladePreBudgetMin (Read or Write) Description Blade PreBudget Min Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
iDRAC.PrivateStore.CIPHERSuiteDisable (Read or Write) Description CIPHER Suite Disable Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.FPButtonCapability (Read or Write) Description Front Panel Button Capability Legal Values ● Integral values from 0 to 255 Default Value 16 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.LastPwrState (Read or Write) Description Last Power State Legal Values ● Off-0 ● On-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.LCDFailSafeMsg (Read or Write) Description LCD Fail Safe Message Legal Values ● String of up to 32 ASCII characters.
Dependancy None iDRAC.PrivateStore.LCDFailSafeMsg3 (Read or Write) Description LCD Fail Safe Message 3 Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.LCDFailSafeMsg4 (Read or Write) Description LCD Fail Safe Message 4 Legal Values ● String of up to 32 ASCII characters.
Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.LCDFailSafeMsg8 (Read or Write) Description LCD Fail Safe Message 8 Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.
License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.ROMBStatus (Read or Write) Description ROMB Status Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.PrivateStore.State (Read or Write) Description Current State Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
License Required iDRAC Basic Dependancy None iDRAC.Racadm.MaxSessions (Read Only) Description Specifies the maximum number of active Remote Racadm sessions allowed. Legal Values ● Integral values from 0 to 8 Default Value 2 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Racadm.Timeout (Read or Write) Description Defines the idle timeout in seconds of the Remote Racadm interface.
Legal Values ● Integral values from 0 to 5 Default Value 3 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.RedfishEventing.DeliveryRetryIntervalInSeconds (Read or Write) Description This represents the number of seconds between retry attempts for sending any given Event. Legal Values ● Integral values from 5 to 60 Default Value 5 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.RedfishEventing.
iDRAC.RemoteHosts.MessageSubjectPrefix (Read or Write) Description Specifies a custom message subject prefix for email alert messages. Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RemoteHosts.SenderEmail (Read or Write) Description Specifies the address of emails sent by iDRAC Legal Values ● String of up to 254 ASCII characters.
Default Value 25 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RemoteHosts.SMTPSASL (Read Only) Description SMTP SASL Legal Values ● Integral values from 0 to 65535 Default Value 2 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.RemoteHosts.SMTPServerIPAddress (Read or Write) Description Address of the network SMTP server Legal Values ● String of up to 254 ASCII characters. Default Value 0.0.0.
iDRAC.RFS This group contains the attributes that provides details about iDRAC RFS NOTE: To perform the complete workflow for RFS and set attributes, refer to remoteimage. iDRAC.RFS.AttachMode (Read or Write) Description RFS Media attach mode Legal Values ● Auto Attach-0 ● Attach-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RFS.
Dependancy None iDRAC.RFS.MediaAttachState (Read Only) Description RFS Media attach state Legal Values ● Detached-0 ● Attached-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.RFS.Password (Read or Write) Description Specifies the remote file share password. Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RFS.
iDRAC.RFS.User (Read or Write) Description Specifies the remote file share user. Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RFS.WriteProtected (Read Only) Description RFS Write Protection Legal Values ● Read Only-0 ● Read Write-1 Default Value 0 Write Privilege Server Configuration License Required Dependancy None iDRAC.
iDRAC.RSASecurID2FA.RSASecurIDClientID (Read or Write) Description Displays the RSA Authentication Key Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.RSM This group contains the attributes that provides details about iDRAC RSM group. iDRAC.RSM.ChassisPowerInfoCapability (Read Only) Description Indicates Chassis Power cap and Chassis Infrastructure power.
License Required iDRAC Basic Dependancy None iDRAC.RSM.RSMCapability (Read Only) Description Indicates if system is Server Based Management Capable or not Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.RSM.RSMSetting (Read Only) Description Indicates the current Server Based Management setting.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.SCEP.Enable (Read or Write) Description Enables or disables Simple Certificate Enrollment. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy SCEP CA-URL must be configured before SCEP can be enabled. iDRAC.SCEP.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.SCV.CertificateUploadStatus (Read Only) Description For Factory to poll the SCV certificate upload status till Error or Complete, before initiating the Certificate download operation. Legal Values ● ● ● ● Default Value 0 Write Privilege Configure iDRAC None-0 In Progress-1 Error-2 Complete-3 License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.SecondaryNIC.DNSDRACName (Read or Write) Description SecondaryNIC DNS RAC Name Legal Values ● String of up to 63 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.DNSFromDHCP (Read or Write) Description SecondaryNIC Domain Name server Legal Values ● Disable● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.
● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.Duplex (Read Only) Description SecondaryNIC Duplex Legal Values ● Half● Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.HostName (Read or Write) Description SecondaryNIC Host Name Legal Values ● String of up to 62 ASCII characters.
License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.IPV4Gateway (Read or Write) Description SecondaryNIC IPV4 Gate way Legal Values ● String of up to 16 ASCII characters. Default Value 192.168.0.1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.IPV4NetMask (Read or Write) Description SecondaryNIC IPV4 Net mask Legal Values ● String of up to 16 ASCII characters. Default Value 255.255.255.
iDRAC.SecondaryNIC.MTU (Read Only) Description SecondaryNIC Mac Address Legal Values ● Integral values from 576 to 1500 Default Value 1500 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.NICEnable (Read or Write) Description SecondaryNIC Enable Legal Values ● Disable● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.
Legal Values ● 10● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.RegisterHostDNS (Read or Write) Description SecondaryNIC DNS Register Legal Values ● Disable● Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecondaryNIC.
License Required iDRAC Basic Dependancy None iDRAC.SecureDefaultPassword This group contains the attributes that provides details about iDRAC secure default password. iDRAC.SecureDefaultPassword.AESiv (Read Only) Description AES IV Legal Values ● String of up to 32 ASCII characters. Default Value FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecureDefaultPassword.
● True-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecureDefaultPassword.ForceChangePassword (Read or Write) Description Force change of password if default password is still in effect. Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure User License Required iDRAC Basic Dependancy None iDRAC.SecureDefaultPassword.
Legal Values ● INVALID-0 ● VALID-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security This group contains the attributes that provides details about iDRAC security. iDRAC.Security.AllowIpmiI2cCommands (Read or Write) Description Enable IPMI commands that result in I2C traffic to IDRAC/system buses Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.Security.CsrCommonName (Read or Write) Description Specifies the CSR Common Name (CN) being certified (usually the web server's Fully Qualified Domain Name (FQDN). Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security.CsrCountryCode (Read or Write) Description Specifies the CSR Country Code (CC). Legal Values ● String of up to 2 ASCII characters.
Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security.CsrOrganizationName (Read or Write) Description Specifies the CSR Organization Name (O) Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security.
iDRAC.Security.FieldSupportDebugAESIV (Read or Write) Description FSD AES Initialization Vector Legal Values ● String of up to 32 ASCII characters. Default Value FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security.FIPSMode (Read or Write) Description Enables or Disables the FIPS mode compliance. Enabling FIPS mode resets iDRAC configuration to factory defaults.
iDRAC.Security.IPMIBootstrapCredentialProvisioning (Read or Write) Description Enable or Disable IPMI Bootstrap Credential provisioning Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege License Required Dependancy None iDRAC.Security.MainCertPath (Read or Write) Description CSR certificate location Legal Values ● String of up to 255 ASCII characters. Default Value /etc/certs/CA/certs/host.
iDRAC.Security.PasswordMinimumLength (Read or Write) Description Password must be a minimum of the specified characters. Legal Values ● Integral values from 0 to 20 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy Property will be ignored if PasswordRequireRegex is not blank. iDRAC.Security.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy Property will be ignored if PasswordRequireRegex is not blank. iDRAC.Security.PendingCSRKeyPath (Read or Write) Description Pending CSR key location Legal Values ● String of up to ASCII characters. Default Value /etc/certs/csr/host.key Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Security.
License Required iDRAC Basic Dependancy None iDRAC.Security.SPIFieldSupportDebugAESIV (Read or Write) Description SPI FSD AES Initialization Vector Legal Values ● String of up to 32 ASCII characters. Default Value FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate This group contains the attributes that provides details about iDRAC security certificate. iDRAC.SecurityCertificate.
● ● ● ● ● ● ● ● SEKM_SSL_CERT-6 KMS_SERVER_CA-7 RSYSLOG_SERVER_CA-8 BIOS_HTTPS_BOOT_CERT-9 SMARTCARD_USER-10 SMARTCARD_CA-11 RSA_CA-12 SCEP_CA-13 Default Value 6 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate.CertType (Read or Write) Description Specifies the certificate type for CertData used in SCP Import. Possible values are SEKM_SSL_CERT and KMS_SERVER_CA. Legal Values ● String of up to 64 ASCII characters.
iDRAC.SecurityCertificate.IsGroupInstanceValid (Read Only) Description Specifies if this group instance is valid or not. Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate.IssuerCommonName (Read Only) Description Specifies the common name of the entity that verified the information and signed the certificate. Legal Values ● String of up to 64 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate.IssuerOrganizationalUnit (Read Only) Description Specifies the organizational unit of the entity that verified the information and signed the certificate. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate.
iDRAC.SecurityCertificate.SubjectCountryCode (Read Only) Description Specifies the country code of the entity a certificate belongs to. Legal Values ● String of up to 2 ASCII characters. Default Value US Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCertificate.SubjectLocality (Read Only) Description Specifies the locality of the entity a certificate belongs to. Legal Values ● String of up to 64 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SecurityCSC This group contains the attributes that provide details about custom security certificates. iDRAC.SecurityCSC.CSCCsrBusiness (Read or Write) Description iDRAC Custom Certificate Business Name Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.SecurityCSC.
License Required iDRAC Basic Dependancy None iDRAC.SecurityCSC.CSCCsrDeptName (Read or Write) Description iDRAC Custom Certificate Department Name Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Server Configuration License Required iDRAC Basic Dependancy None iDRAC.SecurityCSC.CSCCsrEmailAddr (Read or Write) Description iDRAC Custom Certificate Email Address Legal Values ● String of up to 254 ASCII characters.
License Required Dependancy None iDRAC.SEKM.AutoSecure (Read or Write) Description Indicates if iDRAC will auto secure all security capable drives. Legal Values ● Disabled-1 ● Enabled-2 Default Value 2 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.iLKMStatus (Read Only) Description Indicates iDRAC LKM status Legal Values ● Disable-1 ● Enable-2 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.
iDRAC.SEKM.KeyCaching (Read or Write) Description Indicates if iDRAC is enabled or disabled for caching the keys used to lock and unlock devices. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.KeyCreationPolicy (Read Only) Description Attribute that specifies the number of keys iDRAC should generate to secure storage devices on a system.
iDRAC.SEKM.KeyN (Read Only) Description Indicates iLKM current authentication key Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.KeyNMinusOne (Read Only) Description Indicates iLKM previous authentication key Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.
iDRAC.SEKM.LicenseInstalled (Read or Write) Description Indicates to the SEKM service on iDRAC if a SEKM license was ever installed on this system. Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.Rekey (Read or Write) Description Allows SCP to enable iDRAC rekey operation. Legal Values ● False-0 ● True-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKM.
iDRAC.SEKM.SEKMStatus (Read Only) Description Indicates if SEKM is enabled or disabled on iDRAC. Legal Values ● ● ● ● Default Value 0 Write Privilege Configure iDRAC Disabled-0 Enabled-1 Failed-2 Unverified Changes Exist-3 License Required Dependancy None iDRAC.SEKM.SetState (Read or Write) Description Internal attribute used by Redfish to enable and disable SEKM. A value of “3-Configured” indicates that SEKM has been enabled and further SEKM changes are possible.
● Reupload to iDRAC iDRAC.SEKMCert.CertificateKeyPath (Read or Write) Description Specifies the Path on iDRAC of the Private Key of the iDRAC SEKM Certificate. Legal Values ● String of up to 255 ASCII characters. Default Value /mnt/persistent_data/data0/cv/private/ekms/iDRACkmipclient.key Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.CertificatePassphrase (Read or Write) Description Specifies the Passphrase provided by the user for the iDRAC SEKM certificate.
iDRAC.SEKMCert.CommonName (Read or Write) Description Specifies the SEKM CSR Common Name (CN) - must be a UserId as given in the certificate if the Key Management Server is setup to use CN for user id. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.CountryCode (Read or Write) Description Specifies the SEKM CSR Country Code (CC). Legal Values ● String of up to 2 ASCII characters.
Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.iDRACCertShareProxyAddress (Read or Write) Description Specifies the Address of the Proxy server to be used by SCP to connect to get the iDRAC SEKM certificate. Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.iDRACCertShareType (Read or Write) Description Specifies the type of share where the iDRAC certificate for SEKM is stored. This is used by SCP to download the iDRAC certificate. Legal Values ● ● ● ● ● ● Default Value 1 Write Privilege Configure iDRAC NFS-1 CIFS-2 Local-3 ftp-4 tftp-5 https-6 License Required Dependancy None iDRAC.SEKMCert.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.LocalityName (Read or Write) Description Specifies the SEKM CSR Locality Name (L). Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.OrganizationName (Read or Write) Description Specifies the SEKM CSR Organization Name (O). Legal Values ● String of up to 64 ASCII characters.
iDRAC.SEKMCert.PendingCSRPath (Read or Write) Description Specifies the Path on iDRAC of the pending SEKM CSR. Legal Values ● String of up to 255 ASCII characters. Default Value /etc/certs/csr/ekms/pending.csr Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.SEKMCACertShareFileName (Read or Write) Description Specifies the file name of the SEKM Server CA certificate. This attribute is used by SCP to locate the SEKM Server CA certificate.
iDRAC.SEKMCert.SEKMCACertShareProxyPassword (Read or Write) Description Specifies the Password of the Proxy Server that SCP will use to connect to get the SEKM Server CA certificate. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.SEKMCACertShareProxyPort (Read or Write) Description Specifies the Port Number for the Proxy Server to be used by SCP to connect to get the SEKM Server CA certificate.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.SEKMCACertShareURI (Read or Write) Description Specifies the file location of the SEKM Server CA certificate. This attribute is used by SCP to locate the SEKM Server CA certificate. Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SEKMCert.
iDRAC.SEKMCert.UserId (Read or Write) Description Specifies the SEKM CSR UserId. This is the user name that represents iDRAC on the Key Management Server. Specify this if the user name in client certificate is set to UID. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SensorThresholds This group contains the attributes that provide details about sensor thresholds. iDRAC.SensorThresholds.
iDRAC.SensorThresholds.UC (Read or Write) Description User configured Upper Critical threshold Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SensorThresholds.UNC (Read or Write) Description User configured Upper Non Critical threshold Legal Values ● Integral values from to Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.Serial.Enable (Read or Write) Description Enables or Disables the iDRAC serial console interface Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Serial.HistorySize (Read or Write) Description Specifies the maximum size of the serial history buffer Legal Values ● Integral values from 0 to 8192 Default Value 8192 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.Serial.IsGroupInstanceValid (Read or Write) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Serial.NoAuth (Read or Write) Description Enables or Disables iDRAC serial console login authentication Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.SerialRedirection This group contains the attributes that provides details about iDRAC Serial Redirection. NOTE: This is supported only for rack and tower systems. iDRAC.SerialRedirection.AutoEnable (Read or Write) Description Attribute for AutoEnable Legal Values ● Disable-0 ● Enable-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SerialRedirection.
iDRAC.ServerBoot.BootOnce (Read or Write) Description Enable Boot Once Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ServerBoot.BootOptionWatchdog (Read or Write) Description Enables or disables the watchdog for boot options. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ServerBoot.
Legal Values ● String of up to 30 ASCII characters. Default Value iDRAC.Embedded.1#SubSystem.1# Write Privilege Not Applicable License Required Dependancy None iDRAC.ServiceModule This group contains the attributes that provides details about iDRAC Service module. iDRAC.ServiceModule.ChipsetSATASupported (Read or Write) Description Monitors SMART attributes of devices behind chipset SATA controller and audits appropriately in Lifecycle Log.
iDRAC.ServiceModule.HostSNMPOMSAAlert (Read or Write) Description Maps the iDRAC LCL into OMSA SNMP traps. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy iDRAC.ServiceModule.HostSNMPAlert should be Enabled iDRAC.ServiceModule.
iDRAC.ServiceModule.NetworkConnection (Read Only) Description ServiceModule attribute for network connection availability on Host Legal Values ● Not Available-0 ● Available-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ServiceModule.OMSAPresence (Read Only) Description Indicates if OMSA is present on the host or not.
iDRAC.ServiceModule.ServiceModuleState (Read Only) Description Specifies the state of the service module on the system Legal Values ● Not Running-0 ● Running-1 ● Not running (TLS error)-2 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ServiceModule.ServiceModuleVersion (Read Only) Description Provides the installed version of iDRAC Service Module (iSM). Legal Values ● String of up to 256 ASCII characters.
iDRAC.ServiceModule.SWRaidMonitoring (Read or Write) Description Enables or disables monitoring devices behind Software RAID. Legal Values ● Disabled● Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.ServiceModule.
iDRAC.ServiceModule.WMIInfo (Read or Write) Description Populate WMI information via ServiceModule Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Smartcard This group contains the attributes that provides details about iDRAC Smartcard. iDRAC.SmartCard.SmartCardCRLEnable (Read or Write) Description Enables or disables the Certificate Revocation List (CRL).
Legal Values ● String of up to 31 ASCII characters. Default Value public Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMP.AgentEnable (Read or Write) Description Enables or Disables the SNMP Agent on the iDRAC Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMP.
Dependancy None iDRAC.SNMP.SNMPProtocol (Read or Write) Description SNMP Protocol Legal Values ● All-0 ● SNMPv3-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMP.TrapFormat (Read or Write) Description SNMP Trap Format Legal Values ● SNMPv1-0 ● SNMPv2-1 ● SNMPv3-2 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMPAlert NOTE: The iDRAC.SNMP.Alert group is deprecated and replaced with iDRAC.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMPAlert.DestinationType (Read or Write) Description Specifies the destination type for IPMI alerts sent to the alert destination. Legal Values ● Integral values from 0 to 128 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SNMPAlert.
Dependancy Value to be set must be an existing iDRAC user name, and that iDRAC user must be enabled with SNMPv3 support also enabled for that user. iDRAC.SNMPAlert.State (Read or Write) Description Enable SNMP Alert State Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SNMPTRAPIPv4 This group contains the attributes that provides details about iDRAC SNMP TRAP IPv4. iDRAC.SNMPTrapIPv4.
License Required iDRAC Basic Dependancy None iDRAC.SNMPTRAPIPv6 This group contains the attributes that provides details about iDRAC SNMP TRAP IPv6. iDRAC.SNMPTrapIPv6.DestinationNum (Read Only) Description Identifier number for the trap destination. Legal Values ● Integral values from 1 to 4 Default Value 1 Write Privilege Server Configuration License Required Dependancy None iDRAC.SNMPTrapIPv6.DestIPv6Addr (Read or Write) Description See SNMPAlert.5-8.
Legal Values ● String of up to 2048 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SSH.Enable (Read or Write) Description Enables or Disables SSH Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SSH.
Dependancy None iDRAC.SSHCrypto This group contains the attributes that provides details about iDRAC SSH crypto. iDRAC.SSHCrypto.Ciphers (Read or Write) Description Specifies the SSH ciphers. Legal Values ● String of up to 1024 ASCII characters. Default Value chacha20-poly1305@openssh.com,aes128-ctr,aes192-ctr,aes256-ctr,aes128-gcm@openssh.com,aes256gcm@openssh.com Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SSHCrypto.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist This group contains the attributes that provides details about iDRAC SupportAssist. iDRAC.SupportAssist.DefaultIPAddress (Read or Write) Description Default IP address for saving SupportAssist collections to network share. Legal Values ● String of up to 256 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.
iDRAC.SupportAssist.DefaultProtocolPort (Read or Write) Description Default Protocol Port value Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.DefaultShareName (Read or Write) Description Default share name for saving SupportAssist collections to network share. Legal Values ● String of up to 256 ASCII characters.
Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy Registration ID needs to be obtained before Email option configuration iDRAC.SupportAssist.EventBasedAutoCollection (Read or Write) Description Indicates whether SupportAssist event based auto collection features is enabled on this system.
Dependancy None iDRAC.SupportAssist.HostOSProxyPassword (Read or Write) Description Host OS proxy password Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy HostOSProxyConfigured should be Yes-1 iDRAC.SupportAssist.
Legal Values ● No-0 ● Yes-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.MBSELRestoreState (Read or Write) Description Indicates the state of SEL restoration after MB replacement. Legal Values ● ● ● ● ● Default Value 0 Write Privilege Configure iDRAC NotAvailable-0 InProgress-1 Available-2 Partial-3 Failed-4 License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.
iDRAC.SupportAssist.PreferredLanguage (Read or Write) Description Preferred Language for E-mail communication from Dell Legal Values ● ● ● ● ● ● Default Value 0 Write Privilege Configure iDRAC English-0 German-1 French-2 Japanese-3 Spanish-4 Simplified Chinese-5 License Required iDRAC Basic Dependancy Registration ID needs to be obtained before changing language settings. iDRAC.SupportAssist.
iDRAC.SupportAssist.PrimaryContactLastName (Read or Write) Description Primary Contact Last Name for registration Legal Values ● String of up to 50 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.PrimaryContactPhoneNumber (Read or Write) Description Primary Contact Phone Number for registration Legal Values ● String of up to 40 ASCII characters.
iDRAC.SupportAssist.RegistrationID (Read Only) Description Specifies the SupportAssist Registration ID if the system was registered with Dell. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.
iDRAC.SupportAssist.SecondaryContactEmail (Read or Write) Description Secondary Contact Email for registration Legal Values ● String of up to 100 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.SecondaryContactFirstName (Read or Write) Description Secondary Contact First Name for registration Legal Values ● String of up to 50 ASCII characters.
Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.ShippingInfoCompanyName (Read or Write) Description Shipping Info Company Name for registration Legal Values ● String of up to 256 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.
iDRAC.SupportAssist.ShippingInfoStreet2 (Read or Write) Description Shipping Info Street2 for registration Legal Values ● String of up to 100 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.ShippingInfoZip (Read or Write) Description Shipping Info Zip for registration Legal Values ● String of up to 10 ASCII characters.
iDRAC.SupportAssist.SupportAssistEULAAcceptedAtiDRACTime (Read or Write) Description iDRAC time when SupportAssist EULA was accepted. Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SupportAssist.SupportAssistEULAAcceptedByiDRACUser (Read or Write) Description iDRAC Username logged in when SupportAssist EULA was accepted. Legal Values ● String of up to 32 ASCII characters.
License Required iDRAC Basic Dependancy None iDRAC.SysInfo This group contains the attributes that provides details about iDRAC Sysinfo. iDRAC.SysInfo.AcSysRecovery (Read or Write) Description Specifies what State the System will be after AC Recovery Legal Values ● String of up to 18 ASCII characters. Default Value 003c003c0058020000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
Dependancy None iDRAC.SysInfo.BrdRevision (Read or Write) Description Board revision Legal Values ● String of up to 3 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.CMCInfo (Read Only) Description Provides CMC information. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
Legal Values ● String of up to 160 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.CPUExtendedTDP (Read Only) Description CPU Extended TDP info from BIOS Legal Values ● String of up to 256 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
iDRAC.SysInfo.FPStatus (Read or Write) Description FP status Legal Values ● String of up to 8 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.FWVersion (Read or Write) Description String displays the current System BIOS Version Number Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.ISInfos (Read or Write) Description Internal slot information Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.LocalConsoleLockOut (Read or Write) Description Specifies the local console lockout state.
iDRAC.SysInfo.OSNameBinary (Read or Write) Description OS Name in Binary Legal Values ● String of up to 512 ASCII characters. Default Value 0000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.OSNameVolatile (Read or Write) Description OS name Volatile Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.RebrandInfo (Read or Write) Description Provides rebrand information. Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.RedundancyPolicy (Read or Write) Description Redundancy policy Legal Values ● String of up to 20 ASCII characters.
iDRAC.SysInfo.SystemRev (Read or Write) Description Provides the system revision. Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.TPMCompId (Read Only) Description Specifies the TPM firmware DUP component Id. Legal Values ● String of up to 65 ASCII characters. Default Value 123456 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.SysInfo.
iDRAC.SysLog.PowerLogEnable (Read or Write) Description Enable Power Logs Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SysLog.PowerLogInterval (Read or Write) Description Set Power Log Interval Legal Values ● Integral values from 1 to 1440 Default Value 5 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SysLog.
Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.SysLog.SysLogEnable (Read or Write) Description Enables or disables remote syslog Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.Telemetry This group contains the attributes that provides details about iDRAC telemetry. iDRAC.Telemetry.
Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.Telemetry.RSyslogServer1Port (Read or Write) Description Displays the RSyslog server port. Legal Values ● Integral values from 0 to 65535 Default Value 514 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.Telemetry.RSyslogServer2 (Read or Write) Description Displays the Rsyslog server IPv4/IPv6 address or FQDN.
Dependancy None iDRAC.Telemetry.TelemetrySubscription2 (Read Only) Description Displays the JSON string describing the current Telemetry subscription by a Redfish client or Rsyslog server. Legal Values ● String of up to 256 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.Telemetry.
iDRAC.Telemetry.TelemetrySubscription6 (Read Only) Description Displays the JSON string describing the current Telemetry subscription by a Redfish client or Rsyslog server. Legal Values ● String of up to 256 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.Telemetry.TelemetrySubscription7 (Read Only) Description Displays the JSON string describing the current Telemetry subscription by a Redfish client or Rsyslog server.
Dependancy None iDRAC.TelemetryAggregateCUPS.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryAggregateCUPS.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryAggregateCUPS.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryAggregateCUPS.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryAggregationMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryAggregationMetrics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
Dependancy None iDRAC.TelemetryAggregationMetrics.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUConfig This group contains the attributes that provide details about Telemetry CPU configuration. iDRAC.TelemetryCPUConfig.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUConfig.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUConfig.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated.
iDRAC.TelemetryCPUInventory This group contains the attributes that provide details about Telemetry CPU inventory. iDRAC.TelemetryCPUInventory.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUInventory.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetryCPUInventory.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUInventory.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation.
iDRAC.TelemetryCPUMemMetrics.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUMemMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryCPUMemMetrics.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUMemMetrics.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
iDRAC.TelemetryCPURegisters.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPURegisters.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryCPUSensor.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 5 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUSensor.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● Integral values from 10 to 7200 Default Value 60 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryCPUSensor.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value CPUCriticalTrigger, CPUWarnTrigger, TMPCpuCriticalTrigger, TMPCpuWarnTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Datacenter Dependancy None iDRAC.TelemetryCUPS.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryFanSensor.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 5 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFanSensor.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● Integral values from 10 to 7200 Default Value 60 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFanSensor.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value FANCriticalTrigger, FANWarnTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFanSensor.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCConfig.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCConfig.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
License Required Y Dependancy None iDRAC.TelemetryFCConfig.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCInventory This group contains the attributes that provide details about Telemetry FC inventory. iDRAC.TelemetryFCInventory.
License Required Y Dependancy None iDRAC.TelemetryFCInventory.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCInventory.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryFCPortStatistics This group contains the attributes that provides details about iDRAC telemetry FC port statistics. iDRAC.TelemetryFCPortStatistics.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 60 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCPortStatistics.
License Required Y Dependancy None iDRAC.TelemetryFCPortStatistics.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 10 to 7200 Default Value 60 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCPortStatistics.
License Required Y Dependancy None iDRAC.TelemetryFCSensor.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCSensor.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters.
iDRAC.TelemetryFCSensor.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFCSensor.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryFirmwareInventory.FQDD (Read or Write) Description Displays the FQDD of the report. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFirmwareInventory.IsGroupInstanceValid (Read or Write) Description Indicates if the group instance is valid.
Dependancy None iDRAC.TelemetryFirmwareInventory.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFPGASensor This group contains the attributes that provides details about iDRAC telemetry FPGA sensor. iDRAC.TelemetryFPGASensor.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFPGASensor.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryFPGASensor.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated.
iDRAC.TelemetryGPUInventory This group contains the attributes that provide details about Telemetry GPU inventory. iDRAC.TelemetryGPUInventory.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUInventory.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetryGPUInventory.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUInventory.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation.
iDRAC.TelemetryGPUMetrics.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUMetrics.
Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUMetrics.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUStatistics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryGPUStatistics.
License Required Y Dependancy None iDRAC.TelemetryiDRACLogs This group contains the attributes that provide details about Telemetry iDRAC logs. iDRAC.TelemetryiDRACLogs.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryiDRACLogs.
License Required Y Dependancy None iDRAC.TelemetryiDRACLogs.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryiDRACLogs.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryLCLog.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryLCLog.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryMemoryConfig This group contains the attributes that provide details about telemetry memory configurations. iDRAC.TelemetryMemoryConfig.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryMemoryConfig.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetryMemoryConfig.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryMemoryConfig.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation.
iDRAC.TelemetryMemoryInventory.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryMemoryInventory.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryMemoryInventory.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value OnChangeTrigger, OnStartTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryMemoryInventory.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
iDRAC.TelemetryMemorySensor.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryMemorySensor.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICConfig This group contains the attributes that provide details about telemetry NIC configurations. iDRAC.TelemetryNICConfig.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICConfig.
Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICConfig.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICInventory.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICInventory.FQDD (Read Only) Description Displays the FQDD of the report.
License Required Y Dependancy None iDRAC.TelemetryNICInventory.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value OnChangeTrigger, OnStartTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICInventory.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryNICSensor.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICSensor.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
iDRAC.TelemetryNICSensor.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICStatistics This group contains the attributes that provides details about iDRAC telemetry NIC statistics. iDRAC.TelemetryNICStatistics.
iDRAC.TelemetryNICStatistics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNICStatistics.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryNVMeLog.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNVMeLog.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNVMeLog.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryNVMeSMARTData.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryNVMeSMARTData.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryNVMeSMARTData.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPCIDeviceInventory This group contains the attributes that provide details about telemetry PCI devices inventory. iDRAC.TelemetryPCIDeviceInventory.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPCIDeviceInventory.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPCIDeviceInventory.
iDRAC.TelemetryPowerConfig.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerConfig.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerConfig.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value OnChangeTrigger, OnStartTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerConfig.
iDRAC.TelemetryPowerHistoricalTrends.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerHistoricalTrends.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryPowerHistoricalTrends.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerHistoricalTrends.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryPowerMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerMetrics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
iDRAC.TelemetryPowerMetrics.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerStatistics This group contains the attributes that provides details about iDRAC telemetry power statistics. iDRAC.TelemetryPowerStatistics.
iDRAC.TelemetryPowerStatistics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPowerStatistics.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryPSUInventory.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPSUInventory.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPSUInventory.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value OnChangeTrigger, OnStartTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPSUInventory.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPSUMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryPSUMetrics.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
License Required Y Dependancy None iDRAC.TelemetryPSUMetrics.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySensor This group contains the attributes that provides details about iDRAC telemetry sensor. iDRAC.TelemetrySensor.
License Required Y Dependancy None iDRAC.TelemetrySensor.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySensor.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetrySerialLog This group contains the attributes that provides details about iDRAC telemetry serial logs. iDRAC.TelemetrySerialLog.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySerialLog.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetrySerialLog.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 10 to 7200 Default Value 40 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySerialLog.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation.
iDRAC.TelemetryStorageController.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageController.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryStorageController.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value OnChangeTrigger, OnStartTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageController.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageDiskSMARTData.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageDiskSMARTData.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
License Required Y Dependancy None iDRAC.TelemetryStorageDiskSMARTData.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageEnclosure This group contains the attributes that provide details about telemetry storage enclosures. iDRAC.TelemetryStorageEnclosure.
iDRAC.TelemetryStorageEnclosure.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageEnclosure.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStoragePCIeSSD This group contains the attributes that provide details about telemetry storage PCIE SSDs. iDRAC.TelemetryStoragePCIeSSD.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled.
iDRAC.TelemetryStoragePCIeSSD.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStoragePCIeSSD.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation.
iDRAC.TelemetryStoragePhysicalDisk.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStoragePhysicalDisk.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetryStoragePhysicalDisk.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStoragePhysicalDisk.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageSensor.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageSensor.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters.
iDRAC.TelemetryStorageSensor.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageSensor.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server.
License Required Y Dependancy None iDRAC.TelemetryStorageVirtualDisk.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryStorageVirtualDisk.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid.
Dependancy None iDRAC.TelemetryStorageVirtualDisk.RsyslogTarget (Read or Write) Description Enables or disables the transmission of this report to the configured Rsyslog server. Legal Values ● FALSE-0 ● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySystemUsage This group contains the attributes that provides details about iDRAC telemetry system usage. iDRAC.TelemetrySystemUsage.
Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySystemUsage.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetrySystemUsage.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated.
iDRAC.TelemetryThermalConfig This group contains the attributes that provide details about telemetry thermal configurations. iDRAC.TelemetryThermalConfig.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryThermalConfig.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report.
iDRAC.TelemetryThermalConfig.ReportInterval (Read or Write) Description Allows to configure the interval in seconds at which the reports are generated. Configuring the value 0 will stop the interval-based report generation. Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryThermalConfig.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation.
iDRAC.TelemetryThermalMetrics.EnableTelemetry (Read or Write) Description Enables or disables the Telemetry Report. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryThermalMetrics.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
iDRAC.TelemetryThermalMetrics.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value TMPDiskCriticalTrigger, TMPDiskWarnTrigger, TMPCriticalTrigger, TMPWarnTrigger Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryThermalMetrics.
iDRAC.TelemetryThermalSensor.FQDD (Read Only) Description Displays the FQDD of the report. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryThermalSensor.IsGroupInstanceValid (Read Only) Description Indicates if the group instance is valid. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.
● TRUE-1 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryTTYLog This group contains the attributes that provide details about telemetry logs. iDRAC.TelemetryTTYLog.DevicePollFrequency (Read Only) Description Displays the frequency at which the devices are polled. Legal Values ● Integral values from 0 to 600 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryTTYLog.
Legal Values ● Integral values from 0 to 7200 Default Value 0 Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryTTYLog.ReportTriggers (Read or Write) Description Allows to configure the predefined triggers for report generation. Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Y Dependancy None iDRAC.TelemetryTTYLog.
Legal Values ● Integral values from 1 to 2 Default Value 2 Write Privilege Server Configuration License Required Dependancy None iDRAC.Telnet.Port (Read or Write) Description Specifies the port number for the iDRAC Telnet interface Legal Values ● Integral values from 1 to 65535 Default Value 23 Write Privilege Configure iDRAC License Required Dependancy The port number to be set can not be the same as any other service’s port number. iDRAC.Telnet.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Time.iDRACTimeReady (Read or Write) Description iDRAC Time Set Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Time.Timezone (Read or Write) Description Time Zone String Legal Values ● String of up to 32 ASCII characters.
License Required iDRAC Basic Dependancy None iDRAC.Update This group contains the attributes that provides details about iDRAC update. NOTE: fwUpdateIPAddr attribute is applicable for Monolithic & FX2/FX2s only. iDRAC.Update.Begin (Read or Write) Description Out-Of-Band system initiate firmware update Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Update.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy RSM Capability should be enabled iDRAC.Update.FwUpdateIPAddr (Read or Write) Description Specifies the TFTP server address to be used for iDRAC firmware update operations Legal Values ● String of up to 254 ASCII characters. Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Update.
iDRAC.Update.Progress (Read or Write) Description Specifies the progress of firmware update. Legal Values ● Integral values from 0 to 100 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.Update.RollbackFeatureEFB (Read or Write) Description Specifies the list of features that are supported by the rollback iDRAC firmware. Legal Values ● String of up to 64 ASCII characters.
iDRAC.USB.ConfigurationXML (Read or Write) Description Specifies whether configuration can be performed using USB management port. Legal Values ● ● ● ● Default Value 1 Write Privilege Server Configuration Disabled-0 Enabled while server has default credential settings only-1 Enabled-2 Enabled only for compressed configuration files-3 License Required iDRAC Basic Dependancy None iDRAC.USB.HostFrontPortsDynamicMode (Read Only) Description Provides the host front USB port dynamic mode status.
iDRAC.USB.PortStatus (Read or Write) Description Enables or disables the iDRAC front USB port. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.USB.ZipPassword (Read or Write) Description Specifies password that is used to unlock zip file containing Server Configuration Profile on USB drive. Legal Values ● String of up to 128 ASCII characters.
Default Value 2 Write Privilege Configure User License Required iDRAC Basic Dependancy Need valid username and password to set the attribute. The value could not be set to none if privacy protocol is not none. iDRAC.Users.EmailAddress (Read or Write) Description Specifies the email address to use for Simple 2FA for the user. Legal Values ● String of up to 254 ASCII characters.
Dependancy Need valid username to set the attribute. iDRAC.Users.IpmiLanPrivilege (Read or Write) Description Specifies the maximum privilege on the IPMI LAN channel Legal Values ● ● ● ● Default Value 15 Write Privilege Configure User User-2 Operator-3 Administrator-4 No Access-15 License Required iDRAC Basic Dependancy Both UserName and Password must be configured prior to sets iDRAC.Users.
Dependancy Cannot be set without User Name being set first iDRAC.Users.PrivacyProtocol (Read or Write) Description The Privacy Protocol for SNMP v3 Legal Values ● None-0 ● DES-1 ● AES-2 Default Value 2 Write Privilege Configure User License Required iDRAC Basic Dependancy Need valid username and password to set the attribute. The value could not be set to AES or DES if authentication protocol is none. iDRAC.Users.
License Required Dependancy Both UserName and Password must be configured prior to any setting. iDRAC.Users.SHA1v3Key (Read or Write) Description Specifies the SHA1 hash of the SNMPv3 key Legal Values ● String of up to 40 ASCII characters. Default Value None Write Privilege Configure User License Required iDRAC Basic Dependancy Cannot be set without User Name being set first iDRAC.Users.
iDRAC.Users.Simple2FATimestamp (Read or Write) Description Specifies the timestamp for the Simple 2FA token for the user. Legal Values ● String of up to 32 ASCII characters. Default Value 0 Write Privilege Configure User License Required iDRAC Basic Dependancy None iDRAC.Users.Simple2FAToken (Read or Write) Description Specifies the Simple 2FA token for the user. Legal Values ● String of up to 6 ASCII characters.
Default Value None Write Privilege Configure User License Required iDRAC Basic Dependancy None iDRAC.Users.SSHPublicKey1 (Read or Write) Description Specifies SSH Public Key 1 for the user. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure User License Required iDRAC Basic Dependancy None iDRAC.Users.SSHPublicKey2 (Read or Write) Description Specifies SSH Public Key 2 for the user. Legal Values ● String of up to 128 ASCII characters.
iDRAC.Users.UseEmail (Read or Write) Description Enables or disables the use of email to communicate the 2FA code to destination defined in EmailAddress for the user. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure User License Required Dependancy Both UserName and Password must be configured prior to setting to Enabled. iDRAC.Users.UserName (Read or Write) Description iDRAC User Name Legal Values ● String of up to 16 ASCII characters.
iDRAC.vFlashPartition This group contains the attributes that provides details about iDRAC vFlash partition. iDRAC.vFlashPartition.AccessType (Read or Write) Description vFlash Partition Access Type Legal Values ● Read Write-0 ● Read Only-1 Default Value 1 Write Privilege Virtual Media License Required Dependancy vFlash SD card has to be enabled. Partition at the specified index has to be created. AttachState should be Detached. iDRAC.vFlashPartition.
● FAT32-4 Default Value 0 Write Privilege Virtual Media License Required Dependancy vFlash SD card has to be enabled. Partition at the specified index has to be created. iDRAC.vFlashPartition.IsGroupInstanceValid (Read or Write) Description vFlash Partition Valid Group Legal Values ● Invalid-0 ● Valid-1 Default Value 0 Write Privilege Server Configuration License Required Dependancy None iDRAC.vFlashPartition.
Legal Values ● String of up to 17 ASCII characters. Default Value None Write Privilege Virtual Media License Required Dependancy vFlashSD has to be enabled iDRAC.vFlashSD.Bitmap (Read or Write) Description Bitmap Legal Values ● String of up to 64 ASCII characters. Default Value 0x0000000000000000 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.vFlashSD.
Default Value 0 Write Privilege Virtual Media License Required Dependancy vFlashSD has to be enabled iDRAC.vFlashSD.Licensed (Read Only) Description Specifies if the vFlash SD is licensed Legal Values ● Not Licensed-0 ● Licensed-1 Default Value 0 Write Privilege Virtual Media License Required Dependancy vFlashSD has to be enabled iDRAC.vFlashSD.
Dependancy vFlashSD has to be enabled iDRAC.vFlashSD.WriteProtect (Read Only) Description Enable vFlash SD Write Protect Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Virtual Media License Required Dependancy vFlashSD has to be enabled iDRAC.VirtualConsole This group contains the attributes that provides details about iDRAC virtual console. iDRAC.VirtualConsole.
Default Value 2 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualConsole.BootCaptureFileCount (Read or Write) Description Boot Capture File Count Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.BootCaptureFileName (Read Only) Description Virtual Console Boot Capture filename Legal Values ● String of up to 255 ASCII characters.
iDRAC.VirtualConsole.BootCaptureSequence (Read or Write) Description Virtual Console Boot Capture sequence Legal Values ● Integral values from 0 to 2 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.BSODBootCaptureFileName (Read Only) Description Virtual Console BSOD Capture filename Legal Values ● String of up to 255 ASCII characters. Default Value bsod.
Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.CrashCaptureRunning (Read or Write) Description Crash Capture Running status Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.
License Required Dependancy None iDRAC.VirtualConsole.EncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualConsole.
iDRAC.VirtualConsole.LocalVideo (Read or Write) Description Enables or disables the local server video. Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualConsole.MaxBootCaptureFileSize (Read Only) Description Virtual Console Boot Capture maximum file size Legal Values ● Integral values from 0 to 2097152 Default Value 2097152 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.
iDRAC.VirtualConsole.Port (Read or Write) Description Specifies the virtual KVM port. Legal Values ● Integral values from 10 to 65535 Default Value 5900 Write Privilege Configure iDRAC License Required Dependancy The port number to be set can not be the same as any other service’s port number. iDRAC.VirtualConsole.Timeout (Read or Write) Description Specifies the idle timeout in seconds for the Virtual Console.
Legal Values ● String of up to ASCII characters. Default Value dvc Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.VNCRunning (Read or Write) Description Indicates VNC is running. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualConsole.
Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualMedia.Attached (Read or Write) Description Used to attach virtual devices to the system via the USB bus Legal Values ● Detached-0 ● Attached-1 ● AutoAttach-2 Default Value 2 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.
● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.FloppyEmulation (Read or Write) Description When Disabled, the virtual floppy disk is recognized as a removable disk by Windows OS Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.ImageCreationProgress (Read or Write) Description Specifies the progress of image creation.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.ImagePath (Read or Write) Description Virtual Media image path Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.ImageSize (Read or Write) Description Specifies the image size of Virtual Media.
iDRAC.VirtualMedia.KeyValid (Read or Write) Description Indicates Virtual Media key valid. Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.VirtualMedia.MaxSessions (Read Only) Description Provides the maximum number of the Virtual Media sessions allowed. Legal Values ● Integral values from 0 to 1 Default Value 1 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VirtualMedia.
iDRAC.VNCServer.ActiveSessions (Read Only) Description VNC Server Current Active VNC Sessions Legal Values ● Integral values from 0 to 2 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VNCServer.Enable (Read or Write) Description Enable VNC Server Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VNCServer.
Legal Values ● Integral values from 1024 to 65535 Default Value 5950 Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VNCServer.Password (Read or Write) Description VNC Server Password Legal Values ● String of up to 8 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required Dependancy None iDRAC.VNCServer.
Write Privilege Configure iDRAC License Required Dependancy None iDRAC.WebServer This group contains the attributes that provides details about iDRAC web server iDRAC.WebServer.ColumnPickerStorage1 (Read or Write) Description Last Used Domain Name for GUI login Legal Values ● Integral values from 0 to 2147483647 Default Value 0 Write Privilege License Required iDRAC Basic Dependancy None iDRAC.WebServer.
License Required iDRAC Basic Dependancy None iDRAC.WebServer.ControlCollaboration (Read or Write) Description Control Collaboration Legal Values ● Integral values from 1 to 8 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.
iDRAC.WebServer.Http2Enable (Read or Write) Description Enables or Disables HTTP2 support for iDRAC webserver Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.
Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.LowerEncryptionBitLength (Read or Write) Description Lower Encryption Bit Length Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.Timeout (Read or Write) Description Specifies the web server idle timeout. Legal Values ● Integral values from 60 to 10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC.WebServer.TitleBarOption (Read or Write) Description Specifies what to display in the title bar.
Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None iDRAC Attributes 843
5 InfiniBand Attributes This section provides details about the InfiniBand attribute groups and objects. NOTE: See the racadm help for possible values instead of using numeric values to enable or disable the InfiniBand attributes . Topics: • • • • • • • • • InfiniBand.DCBSettings InfiniBand.DeviceLevelConfig InfiniBand.FrmimgMenu InfiniBand.IscsiFirstTgtParams InfiniBand.IscsiGenParams InfiniBand.IscsiInitiatorParams InfiniBand.NICConfig InfiniBand.NICPartitioningConfig InfiniBand.
InfiniBand.DCBSettings.PriorityFlowControl (Read Only) Description Indicates whether the Priority Flow Control capability is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege Login License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.DeviceLevelConfig The following section provides information about the objects in the InfiniBand.DeviceLevelConfig group. InfiniBand.DeviceLevelConfig.
License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.DeviceLevelConfig.PartitionStateInterpretation (Read Only) Description Describes how partitioning is implemented and how the PartitionState attribute is used in the controller. A value of Fixed signifies that partition states are locked and that the current values of PartitionState[n] will not change.
Legal Values ● Available ● Unavailable Default Value N/A Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.DeviceLevelConfig.VFAllocBasis (Read Only) Description Defines the domain in which Virtual Functions are allocated; either Port or Device. NOTE: A device which implements less than 1 PF per physical port must use Device level VF allocation.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.DeviceLevelConfig.VirtualizationMode (Read or Write) Description The Virtualization Mode setting for the device. Specifies the type of virtualization used by the controller on all ports. Legal Values ● Integral values from 0 to 256 Default Value 1 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.
InfiniBand.IscsiFirstTgtParams.ConnectFirstTgt (Read or Write) Description Enables or disables connecting to the first iSCSI target. Not available if VndrConfigPage.iSCSIBootSupport is unavailable. Legal Values ● Enabled ● Disabled Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiFirstTgtParams.FirstTgtBootLun (Read or Write) Description First iSCSI storage target boot Logical Unit Number (LUN).
InfiniBand.IscsiFirstTgtParams.FirstTgtIpAddress (Read or Write) Description IP address of the first iSCSI target. Legal Values ● Valid IPv4 or IPv6 address Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write) Description iSCSI Qualified Name (IQN) of the first iSCSI storage target.
InfiniBand.IscsiGenParams.ChapMutualAuth (Read or Write) Description To use mutual CHAP authentication, specifies an initiator secret on the Initiator Parameters page and configure that secret on the target. Legal Values ● Enabled ● Disabled Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiGenParams.
InfiniBand.IscsiGenParams.TcpIpViaDHCP (Read or Write) Description Setting to enable acquisition of IPv4 TCP/IP parameters from DHCP. Legal Values ● Enabled ● Disabled Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiInitiatorParams The following section provides information about the objects in the InfiniBand.IscsiInitiatorParams group. InfiniBand.IscsiInitiatorParams.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiInitiatorParams.IscsiInitiatorIpAddr (Read or Write) Description Specifies the IP address of the iSCSI initiator. Legal Values ● String from 2 - 39 characters (IPv4 or IPv6 gateway) Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.IscsiInitiatorParams.
InfiniBand.NICConfig The following section provides information about the objects in the InfiniBand.NICConfig group. InfiniBand.NICConfig.BannerMessageTimeout (Read or Write) Description Specify the number of seconds that the OptionROM banner is displayed during POST. Legal Values ● Integral values from 0 - 14 Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.NICConfig.
Legal Values ● ● ● ● ● ● Default Value None Write Privilege Server Control PXE iSCSI FCoE NONE iSCSIPrimary iSCSISecondary License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.NICConfig.LnkSpeed (Read or Write) Description Specifies the port speed used for the selected boot protocol.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.NICPartitioningConfig.NumberPCIFunctionsSupported (Read Only) Description The number of PCI Physical Functions supported on this port. This value may change depending on the support and configuration of NParEP. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.
Legal Values ● None Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.DCBXSupport (Read only) Description Indicates whether Data Center Bridging (DCB) capability is supported. Legal Values ● None Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.
InfiniBand.VndrConfigPage.FCoEOffloadSupport (Read only) Description Indicates whether FCoE Offload capability is supported. Legal Values ● None Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.FeatureLicensingSupport (Read only) Description Indicates whether Dell Feature Licensing capability is supported.
Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.VndrConfigPage.iSCSIOffloadSupport (Read Only) Description Indicates whether the iSCSI Offload capability is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.VndrConfigPage.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.VndrConfigPage.NicMode (Read or Write) Description Enable/Disable the NIC personality on the port. This setting is for when operating in non-NPar mode only. Note: This personality type should be specified as the port default if RDMA is not supported or has dependencies on other device modes or settings.
License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.OnChipThermalSensor (Read only) Description Indicates whether an on-chip thermal sensor is available. Legal Values ● None Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.OSBMCManagementPassThrough (Read only) Description Indicates whether OS-BMC Management Pass Through capability is supported.
InfiniBand.VndrConfigPage.PXEBootSupport (Read only) Description Indicates whether PXE Boot capability is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependancy None InfiniBand.VndrConfigPage.RDMANICModeOnPort (Read or Write) Description Specify use of the port for both L2-Ethernet and RDMA traffic. This setting is for when operating in Non-NPAR mode only.
InfiniBand.VndrConfigPage.SNAPI (Read Only) Description Indicates the adapter supports SNAPI functionality by either special interfacing to the PCI slot connector or via cabling to another PCI slot. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.VndrConfigPage.SNAPIState (Read Only) Description Indicates whether SNAPI functionality is enabled.
InfiniBand.VndrConfigPage.TXBandwidthControlMinimum (Read Only) Description Indicates whether Transmit (TX) Bandwidth Control Minimum capability is supported Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable InfiniBand.VndrConfigPage.TXFlowControl (Read Only) Description Indicates whether Transmit (TX) Flow Control capability is supported.
InfiniBand.VndrConfigPage.VPI (Read Only) Description Indicates whether Virtual Protocol Interconnect (VPI) functionality is supported.
6 Lifecycle Controller Attributes This section provides details about the Lifecycle Controller attribute groups and objects. Topics: • • LifecycleController.LCAttributes LifecycleController.OSD LifecycleController.LCAttributes This group contains the Lifecycle controller LC attributes details. NOTE: A job successfully configured using the autoupdate or autobackup feature settings can be deleted only if the job is currently not running or downloading. LifecycleController.LCAttributes.
Write Privilege Server Configuration License Required iDRAC Enterprise Dependancy None LifecycleController.LCAttributes.BIOSRTDRequested (Read or Write) Description Allows to reset all the BIOS attributes to the default state. After this property is enabled, restart the server to view the default values of BIOS. Legal Values ● False-0 ● True-1 ● OEMIDDefaults-2 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None LifecycleController.LCAttributes.
LifecycleController.LCAttributes.IgnoreCertWarning (Read or Write) Description Ignore Certificate warning default when not provided. Legal Values ● Off-0 ● On-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None LifecycleController.LCAttributes.IPAddress (Read or Write) Description IP Address of the network share Legal Values ● String of up to 255 ASCII characters.
LifecycleController.LCAttributes.LifecycleControllerState (Read or Write) Description Enables or disables Lifecycle Controller. Legal Values ● Disabled-0 ● Enabled-1 ● Recovery-2 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic, iDRAC Express, or iDRAC Enterprise Dependancy None LifecycleController.LCAttributes.PartConfigurationUpdate (Read or Write) Description Apply hardware configuration to the replaced part on part replacement.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependancy None LifecycleController.LCAttributes.StorageHealthRollupStatus (Read Only) Description Specifies the storage health rollup status. Legal Values ● Integral values from 1 to 4 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None LifecycleController.LCAttributes.SystemID (Read Only) Description Dell System ID Legal Values ● String of up to 4 ASCII characters.
LifecycleController.LCAttributes.UserProxyServer (Read or Write) Description Proxy Server default if not provided. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None LifecycleController.LCAttributes.
LifecycleController.OSD This group contains the Lifecycle controller OSD attributes details. LifecycleController.OSD.AnswerFileName (Read Only) Description Specifies the Name of the Answer File present on the share to be used for OS Deployment. Configurable via Server Configuration Profile (SCP) feature only. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Not Applicable License Required iDRAC Basic Dependancy None LifecycleController.OSD.
LifecycleController.OSD.OSMediaName (Read Only) Description Specifies the Name of the OS media present on the share to be used for OS Deployment. Configurable via Server Configuration Profile (SCP) feature only. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Not Applicable License Required iDRAC Basic Dependancy None LifecycleController.OSD.
LifecycleController.OSD.OSMediaSharePassword (Read Only) Description Specifies the Password for the share that contains OS media for OS Deployment. Configurable via Server Configuration Profile (SCP) feature only. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Not Applicable License Required iDRAC Basic Dependancy None LifecycleController.OSD.OSMediaShareType (Read Only) Description Specifies the Type of the share that contains OS media for OS Deployment.
LifecycleController.OSD.SupportedOSList (Read Only) Description Lists all the supported Operating Systems for OS Deployment. Configurable via Server Configuration Profile (SCP) feature only. Legal Values ● String of up to 1024 ASCII characters.
7 NIC Attributes This section provides details about the NIC attribute groups and objects. Topics: • • • • • • • • • • • • • • • • • • • • NIC.ConfigureFormn NIC.DCBSettings NIC.DeviceLevelConfig NIC.FCOECapabilities NIC.FCOEConfiguration NIC.FCOEGenParams NIC.FrmimgMenu NIC.GlobalBandwidthAllocation NIC.iSCSIConfig NIC.IscsiFirstTgtParams NIC.IscsiGenParams NIC.IscsiInitiatorParams NIC.IscsiSecondaryDeviceParams NIC.IscsiSecondTgtParams NIC.LnkSpeedConfig NIC.NICConfig NIC.NICPartitioningConfig NIC.
NIC.ConfigureFormn.FCoEOffloadMode (Read or Write) Description Enable/Disable the FCoE personality on the partition. Replace n with the number of the partition. Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.FIPMacAddr (Read Only) Description Permanent FIP-MAC address for FCoE assigned during manufacturing. Specified on a per partition basis.
NIC.ConfigureFormn.IscsiMacAddr (Read Only) Description Permanent MAC address for iSCSI offload assigned during manufacturing. Specified on a per partition basis. Replace n with the number of the partition. If supported, the current address value should be readable at all times, irrespective of feature and partition enablement. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.
NIC.ConfigureFormn.L2IscsiMacAddr (Read Only) Description The Permanent combination Ethernet and iSCSI Offload MAC address of the partition assigned during manufacturing. Replace n with the number of the partition. The current address value should be readable at all times, irrespective of feature and partition enablement. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.
NIC.ConfigureFormn.NumberVFAdvertised (Read or Write) Description This value is the number of PCI Virtual Functions Advertised by the partition in PCI config space when operating in the NPar+SR-IOV virtualization mode. The value of this attribute may be the same across partitions or be settable on an individual partition basis depending on implementation. Note: This attribute is only defined for the browser and does NOT have any x-UEFI mapping.
NIC.ConfigureFormn.PortNumber (Read Only) Description Port that the partition belongs to. Replace n with the number of the partition. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.SVID (Read or Write) Description When Switch Dependent Partitioning (SDP) is enabled,each partition will be assigned a pre-set Switch VLAN Identifier (SVID).
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.VirtIscsiFIPMacAddr (Read or Write) Description Programmatically assignable combination iSCSI Offload and FIP-MAC address for FCoE. Virtual addresses written will also generate corresponding VWWNN and VWWPN addresses as defined in Y741D. Replace n with the number of the partition. The supported method of reverting to the permanent MAC address is by writing 0's as the virtual address.
NIC.ConfigureFormn.VirtL2IscsiFIPMacAddr (Read or Write) Description Programmatically assignable combination Ethernet, iSCSI Offload and FIP-MAC address for FCoE. Virtual addresses written will also generate corresponding VWWNN and VWWPN addresses as defined in Y741D. Replace n with the number of the partition. The supported method of reverting to the permanent MAC address is by writing 0's as the virtual address.
address has not been set or if it has been cleared by the defined method, its value shall be returned as 0's. Legal Values None Default Value 0000:0000:0000:0000 Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.VirtPortGuid (Read or Write) Description Programmatically assignable partition Port GUID address used when more than one PF is assigned to the port. Programmatic write for support of I/O Identity feature.
NIC.ConfigureFormn.WWN (Read Only) Description Fibre Channel World Wide Node Name identifier for FCoE. Replace n with the number of the partition. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.WWPN (Read Only) Description Fibre Channel World Wide Port Name identifier for FCoE assigned during manufacturing. Replace n with the number of the partition.
NIC.DCBSettings.LocalDCBXWillingMode (Read or Write) Description Indicates whether or not the controller will accept DCB configuration parameters from the link partner as defined in DCBX. Note: Only controllers that allow the disablement of Willing Mode should implement this and the associated Priority Group protocol and bandwidth attributes.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings.PriorityGroup15BandwidthAllocation (Read or Write) Description Indicates the percentage of total port bandwidth is assigned to Priority Group 15. The summation of bandwidth allocations from all Priority Groups must equal 100%.
NIC.DCBSettings.PriorityGroup1ProtocolAssignment (Read or Write) Description Indicates what protocol is assigned to Priority Group 1. Legal Values ● ● ● ● ● Default Value None Write Privilege None All other LAN iSCSI FCoE RoCE None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings.PriorityGroup2BandwidthAllocation (Read or Write) Description Indicates the percentage of total port bandwidth is assigned to Priority Group 2.
NIC.DCBSettings.PriorityGroup3BandwidthAllocation (Read or Write) Description Indicates the percentage of total port bandwidth is assigned to Priority Group 3. The summation of bandwidth allocations from all Priority Groups must equal 100%. Note: NO X-UEFI Mapping Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings.
● FCoE ● RoCE ● None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings.PriorityGroup5BandwidthAllocation (Read or Write) Description Indicates the percentage of total port bandwidth is assigned to Priority Group 5. The summation of bandwidth allocations from all Priority Groups must equal 100%.
NIC.DCBSettings.PriorityGroup6ProtocolAssignment (Read or Write) Description Indicates what protocol is assigned to Priority Group 6. Legal Values ● ● ● ● ● Default Value None Write Privilege None All other LAN iSCSI FCoE RoCE None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings.PriorityGroup7BandwidthAllocation (Read or Write) Description Indicates the percentage of total port bandwidth is assigned to Priority Group 7.
NIC.DCBSettings.PriorityGroupBandwidthAllocation (Read or Write) Description Defines the allocation of network port bandwidth by Priority Group. Bandwidth allocation values are provided in a colon-separated list for all Priority Groups without omission. Values in the list from left to right apply to PG0-7 and PG15 inclusively (e.g. PG0BW:PG1BW:PG2BW:PG3BW:PG4BW:PG5BW:PG6BW:PG7BW:PG15BW). The sum of all Priority Group allocations must equal 100.
NIC.DeviceLevelConfig.EVBModesSupport (Read Only) Description Indicates the type of EVB Modes supported. Legal Values ● ● ● ● Default Value None Write Privilege None VEB VEPA PE Multi-channel License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DeviceLevelConfig.
NIC.DeviceLevelConfig.NParEP (Read or Write) Description Controls enablement of NParEP mode in which more than 8 PCI Physical Functions are exposed by the device. When disabled, the device must expose only a maximum of 8 PFs in the traditional PCI B:D:F addressing mode, regardless of any ARI capability being advertised for SR-IOV support. [Not to be implemented if not supported] Note: Not all PCI slots in all servers are capable of supporting virtualization features based on ARI and SR-IOV.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DeviceLevelConfig.NumPorts (Read or Write) Description Configuration control for Controllers that have the ability to support different port counts per SFF (e.g., SFP-DD, QSFP) or backplane interface. Controllers on implementations that are fixed in their number of ports shall not implement this attribute.
NIC.DeviceLevelConfig.RDMAApplicationProfile (Read or Write) Description Indicates what RDMA configuration profiles are supported by the controller. [Vendor input requested if 1) additional profiles are thought to be needed, 2) if the appl profile can vary by port or partitionm and 3) if appl profiles are supported on a partition basis]. Note: RoCE 1 and RoCE 2 are vendor-specific profiles and should not be interpreted as a version of RoCE.
Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DeviceLevelConfig.STagEtherType (Read or Write) Description Specifies the EtherType to be used by all partitions on the port when Advanced NPar S-tagging is enabled in the Virtualization Mode setting. NOTE: This attribute shall only be implemented when Advanced NPar is supported.
Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DeviceLevelConfig.VirtualizationMode (Read or Write) Description The Virtualization Mode setting for the device. Note: Not all PCI slots in all servers are capable of supporting virtualization features based on ARI and SR-IOV.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCOECapabilities.MaxIOsPerSession (Read Only) Description The maximum number of IOs supported per session. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCOECapabilities.MaxNPIVPerPort (Read Only) Description The maximum number of NPIV WWNs per port.
NIC.FCOECapabilities.MaxNumberOfFCTargets (Read Only) Description The maximum number of FC targets supported. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCOECapabilities.MaxNumberOutStandingCommands (Read Only) Description The maximum number of outstanding commands supported across all sessions.
this requirement (a target previously assigned a boot order value of x is set to 0 when a new target is assigned a value of x). Legal Values ● N/A Default Value 0 Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write) Description Setting to specify whether and in what order a boot from the ports fourth defined target is attempted.
Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.FCoEGenParams (Read Only) Description HII form for FCoE General Parameters configuration. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Description World Wide Port Name of the first FCoE storage target. Note: At present, the Dell FCoE information model only defines one storage target. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.
Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write) Description Retry count for FCoE fabric discovery. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Description Attribute for setting whether system boot to the FCoE target is attempted. Legal Values ● Enabled ● Disabled ● One Time Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FrmimgMenu The following section provides information about the objects in the NIC.FrmimgMenu group. NIC.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.GlobalBandwidthAllocation The following section provides information about the objects in the NIC.GlobalBandwidthAllocation group. NIC.GlobalBandwidthAllocation.MaxBandwidth (Read or Write) Description The maximum percentage of port TX bandwidth allocated to the partition. Oversubscription is allowed. Specified on a per partition basis. Replace n with the number of the partition.
NIC.iSCSIConfig.IscsiFirstTgtParamsRef (Read Only) Description Link to the iSCSI First Target Parameters configuration form. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.iSCSIConfig.IscsiGenParams (Read Only) Description HII form title for the iSCSI General Parameters configuration form.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.iSCSIConfig.IscsiSecondaryDeviceParams (Read Only) Description The HII form title for the secondary iSCSI Device parameters form. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.iSCSIConfig.
NIC.IscsiFirstTgtParams The following section provides information about the objects in the NIC.IscsiFirstTgtParams group. NIC.IscsiFirstTgtParams.ConnectFirstTgt (Read or Write) Description Setting to enable whether connection to the first target is attempted. Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiFirstTgtParams.
NIC.IscsiFirstTgtParams.FirstTgtIpAddress (Read or Write) Description First iSCSI target IP address. Will be either IPv4 or IPv6 format depending on the value of the FirstTgtIpVer attribute. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiFirstTgtParams.
NIC.IscsiGenParams.ChapAuthEnable (Read or Write) Description Setting to enable CHAP Authentication for iSCSI initiator. Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.ChapMutualAuth (Read or Write) Description Setting to enable mutual CHAP authentication between the iSCSI initiator and target.
Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.IpVer (Read or Write) Description Setting displays and allows configuration of the IP version used by iSCSI initiator and targets (Initiator only when a seperate target ipver is implemented). If only one IP version is supported, this attribute should be set to that version and be made Read Only.
NIC.IscsiGenParams.IscsiVLanId (Read or Write) Description VLAN ID used for iSCSI boot. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.IscsiVLanMode (Read or Write) Description Enable/Disable Virtual LAN mode for iSCSI boot. Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.
● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.TcpTimestmp (Read or Write) Description Enable/Disable use of TCP timestamps in network packets Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write) Description iSCSI initiator CHAP secret (0 or 12 to 16 characters in length). If this can be set on a per target basis, then the value for the first target shall be stored here. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiInitiatorParams.IscsiInitiatorGateway (Read or Write) Description iSCSI initiator default Gateway IP address.
NIC.IscsiInitiatorParams.IscsiInitiatorIpv4Gateway (Read or Write) Description The iSCSI initiator default Gateway IP address in IPv4 format when iSCSIDualIPVersionSupport is available. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiInitiatorParams.IscsiInitiatorIpv4PrimDns (Read or Write) Description iSCSI initiator Primary DNS IP Address in IPv4 format when iSCSIDualIPVersionSupport is Available.
Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiInitiatorParams.IscsiInitiatorIpv6PrimDns (Read or Write) Description The iSCSI initiator Primary DNS IP Address in IPv6 format when iSCSIDualIPVersionSupport is Available. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiInitiatorParams.
Dependency Not Applicable NIC.IscsiInitiatorParams.IscsiInitiatorSecDns (Read or Write) Description The iSCSI initiator Secondary DNS IP address. Will be in either IPv4 or IPv6 format depending on the value of the IpVer attribute. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiInitiatorParams.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondaryDeviceParams.UseIndTgtName (Read or Write) Description Use Independent Target Name when multipath I/O is enabled Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondaryDeviceParams.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondTgtParams.SecondTgtChapId (Read or Write) Description Second Target CHAP ID (up to 128 characters in length). If only a single value of CHAP ID supported for all targets then it is stored here Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondTgtParams.
Dependency Not Applicable NIC.IscsiSecondTgtParams.SecondTgtIscsiName (Read or Write) Description The iSCSI Qualified Name (IQN) of the second target Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondTgtParams.
should be greyed out when set to Auto. Note: The speed selection shall only be included if it is supported in the implementation. Legal Values ● True ● False Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.LnkSpeedConfig.
Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.LnkSpeedConfig.10Mbps (Read or Write) Description Speed selector for the specified link speed to be advertised to the link partner for boot protocol operations and possibly including Wake On LAN and shared LOM management features if separate Vaux link speed control is not supported.
NIC.LnkSpeedConfig.200Gbps2 (Read or Write) Description Speed selector for the specified link speed to be advertised to the link partner for boot protocol operations and possibly including Wake On LAN and shared LOM management features if separate Vaux link speed control is not supported. This setting is only valid when LnkSpeedMethod is set to Manual and should be greyed out when set to Auto. Note: The speed selection shall only be included if it is supported in the implementation.
link speed control is not supported. This setting is only valid when LnkSpeedMethod is set to Manual and should be greyed out when set to Auto. Note: The speed selection shall only be included if it is supported in the implementation. Legal Values ● True ● False Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.LnkSpeedConfig.
Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.BootOptionROM (Read or Write) Description This attribute provides enable/disable functionality to the boot entry point (i.e. undi_init) of the legacy Option ROM of the port, effectively controlling the ability to legacy boot via PXE, iSCSI or FCoE.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.FWBootProtocol (Read or Write) Description Selection of the boot protocol for the CNA port when the boot process is local to the controller. Legal Values ● ● ● ● Default Value varies Write Privilege None Legacy PXE UEFI iSCSI HBA UEFI FCoE None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.
NIC.NICConfig.LnkSpeed (Read or Write) Description Selector for link speed(s) to be advertised to link partner for boot operations. Implementations should only include supported link speeds. Existing implementations may remain unchanged, new implementations should not use those speeds listed as deprecated but use the new speeds that have been added that infer what modulation scheme is in use, NRZ or PAM4.
NIC.NICConfig.LnkSpeedConfigRef (Read Only) Description Manual Link Speed configuration form reference for Link speed(s) to be advertised to link partner for boot protocol operations and possibly including Wake On LAN and shared LOM management features if separate Vaux link speed control is not supported. Implementations should only include supported link speeds.
any PF on the shut down port is similarly shut down. Maintaining traffic flow between internal functions when the port is shutdown is implementation dependent. Legal Values ● Enabled ● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.VLanId (Read or Write) Description Specifies the VLAN tag to be used with the selected boot protocol.
NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write) Description Selector for link speed(s) to be advertised to link partner for Vaux operations including Wake On LAN and shared LOM management features. Implementations should only include supported link speeds. Existing implementations may remain unchanged, new implementations should not use those speeds listed as deprecated but use the new speeds that have been added that infer what modulation scheme is in use, NRZ or PAM4.
NIC.NICConfig.WakeOnLanLnkSpeedConfigRef (Read Only) Description Manual Wake On LAN Link Speed configuration Reference form for link speed(s) to be advertised to the link partner for Vaux operations including Wake On LAN and shared LOM management features. Implementations should only include supported link speeds.
NIC.NICPartitioningConfig.ConfigureFormRef (Read Only) Description Link for Partition Configuration form. Individual configuration forms are required for each partition. Replace n with the number of the partition. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.FlowControlSetting (Read or Write) Description Representation and configuration field for Ethernet Flow Control.
Dependency Not Applicable NIC.NICPartitioningConfig.MgmtSVID (Read Only) Description The Management SVID is the Switch VLAN Identifier for the iDRAC service processor when the port is in shared mode. Legal Values None Default Value 1000 Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.NicPartitioning (Read or Write) Description Representation and configuration of enablement of partitioning for the device.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.PartitionState (Read Only) Description Representation of the current enablement state of the partition. There will be an instance of this attribute for each partition. Replace n with the number of the partition. Legal Values ● Enabled ● Disabled Default Value Enabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigGroup The objects in this group manage the vendor configuration settings. NIC.VndrConfigPage.BlnkLeds (Read or Write) Description Blink LEDs for a duration of up to 15 seconds. Only valid for adapters with link LEDs. Legal Values None Default Value 15 Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.DCBSettingsRef (Read Only) Description Configuration page form reference for Data Center Bridge (DCB) Settings Form. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
NIC.VndrConfigPage.DeviceName (Read Only) Description Official product name of the device. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.EEEControl (Read or Write) Description Enables or Disables the Energy Efficient Ethernet feature on the port if supported by the device. If the scope of the control is not port level, then consultation with Dell is required.
NIC.VndrConfigPage.FCOECapabilities (Read Only) Description HII form title for the FCoE Capabilities form. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.FCoECapabilitiesRef (Read Only) Description Configuration page form reference for the FCoE Capabilities Form.
● Disabled Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.FCoEOffloadSupport (Read Only) Description Indicates whether FCoE is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.ForwardErrorCorrection (Read or Write) Description Type of FEC to use on the link. Shall not be implemented on adapters where it is not appropriate. Legal Values ● ● ● ● Default Value Auto Write Privilege None Auto Fire Code (Clause 74) RS-FEC (Clause 91, 108, 134) Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.InfiniBand (Read Only) Description Indicates whether InfiniBand functionality is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.iSCSIBootSupport (Read Only) Description Indicates whether iSCSI Boot is supported.
Dependency Not Applicable NIC.VndrConfigPage.iSCSIDualIPVersionSupport (Read Only) Description Indicates support for simultaneous IPv4 and IPv6 configurations of the iSCSI initiator and iSCSI primary and secondary targets. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
NIC.VndrConfigPage.LinkStatus (Read Only) Description Physical link status of the network port as reported by the controller. Legal Values ● Connected ● Disconnected Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.LnkSpeedAdv (Read or Write) Description Legal Values None Default Value Legacy Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.
NIC.VndrConfigPage.MediaDetection (Read or Write) Description Optional attribute for those implementations that support the querying of the installed SFF device capabilities to assist in link configuration. How this information is used may differ between implementations. Should not be implemented on adapters where it is not used. Legal Values ● Enabled ● Disabled Default Value varies Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.
NIC.VndrConfigPage.NicMode (Read or Write) Description Enable/Disable the NIC personality on the port. This setting is for when operating in non-NPar mode only. Note: This personality type should be specified as the port default if RDMA is not supported or has dependencies on other device modes or settings. Legal Values ● Enabled ● Disabled Default Value Varies Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
NIC.VndrConfigPage.NWManagementPassThrough (Read Only) Description Indicates whether the Network Management Pass Through capability is supported. Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.OmniPath (Read Only) Description Indicates whether Omni-Path functionality is supported.
NIC.VndrConfigPage.PCIDeviceID (Read Only) Description PCI Device ID reported by the controller when operating in non-NPar mode only. The value of the attribute is undefined for controllers operating in NPar mode that change their device IDs or support multiple PCI Device IDs at the partition level. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
NIC.VndrConfigPage.RDMANICModeOnPort (Read or Write) Description Enable/Disable the NIC + RDMA personality on the port. This setting is for when operating in non-NPar mode only. Note: This personality type may be specified as the port default if RDMA traffic can be supported irrespective of any other device mode or setting. Legal Values ● Enabled ● Disabled Default Value Varies Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
NIC.VndrConfigPage.SNAPIState (Read Only) Description Indicates whether SNAPI functionality is enabled. Note: Implement only if SNAPI support is set to Available Legal Values ● Enabled ● Disabled Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.SwitchDepPartitioningSupport (Read Only) Description Indicates whether Switch Dependent Partitioning capability is supported.
NIC.VndrConfigPage.TXBandwidthControlMinimum (Read Only) Description Indicates whether Transmit (TX) Bandwidth Control Minimum capability is supported Legal Values ● Available ● Unavailable Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
Dependency Not Applicable NIC.VndrConfigPage.VirtMacAddr (Read or Write) Description Programmatically assignable MAC address. Programmatic write for support of I/O Identity feature. The supported method of reverting to the permanent MAC address is by writing 0's to the virtual MAC. If the virtual address has not been set or if it has been cleared by the defined method, its value shall be returned as 0's.
Legal Values None Default Value 00:00:00:00:00:00:00:00 Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.VirtWWPN (Read or Write) Description Programmatically assignable Fibre Channel World Wide Port Name identifier for FCoE. Virtual addresses written will also be modified by subsequent writes to the VirtFIP-MAC addesss as defined in Y741D The supported method of clearing this virtual address is by writing 0's as the address.
Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.WakeOnLanLnkSpeedAdv (Read or Write) Description Legal Values None Default Value Legacy Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigPage.
Legal Values ● True ● False Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.WakeOnLanLnkSpeedConfig.100Gbps2WoL (Read or Write) Description Speed selector for the specified link speed to be advertised to the link partner for Vaux operations including Wake On LAN and shared LOM management features.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.WakeOnLanLnkSpeedConfig.10GbpsWoL (Read or Write) Description Speed selector for the specified link speed to be advertised to the link partner for Vaux operations including Wake On LAN and shared LOM management features. If an implementation only supports one pre-OS link speed configuration for boot, WoL and management, then this speed attribute should not be implemented.
NIC.WakeOnLanLnkSpeedConfig.200Gbps1WoL (Read or Write) Description Speed selector for the specified link speed to be advertised to the link partner for Vaux operations including Wake On LAN and shared LOM management features. If an implementation only supports one pre-OS link speed configuration for boot, WoL and management, then this speed attribute should not be implemented. When WakeOnLanLnkSpeedMethod is set to Auto, then this attribute should be greyed-out.
pre-OS link speed configuration for boot, WoL and management, then this speed attribute should not be implemented. When WakeOnLanLnkSpeedMethod is set to Auto, then this attribute should be greyed-out. Note: The speed selection shall only be included if it is supported in the implementation. Legal Values ● True ● False Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.WakeOnLanLnkSpeedConfig.
Default Value True Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC Attributes 959
8 PSU Attributes This section provides details about the PSU attribute groups and objects. Topics: • • • • • • • • • • • PSU.Info.Capacity (Read Only) PSU.Info.EffCapacity (Read Only) PSU.Info.FirmwareVersion (Read Only) PSU.Info.GraphicsURI (Read Only) PSU.Info.HardwareVersion (Read Only) PSU.Info.InputVoltageType (Read Only) PSU.Info.Name (Read Only) PSU.Info.PartNumber (Read Only) PSU.Info.Redundancy (Read Only) PSU.Info.SerialNumber (Read Only) PSU.Info.State (Read Only) PSU.Info.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None PSU.Info.GraphicsURI (Read Only) Description Chassis Power SVG Graphics URI Legal Values ● String of up to 32 ASCII characters. Default Value [need to define] Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None PSU.Info.HardwareVersion (Read Only) Description Chassis Power hardware version Legal Values ● String of up to 32 ASCII characters.
PSU.Info.PartNumber (Read Only) Description [To be filled] Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Not Applicable License Required iDRAC Basic Dependancy None PSU.Info.Redundancy (Read Only) Description will be removed and replaced with System.Chassis.1#Info.
License Required iDRAC Basic Dependancy None PSU Attributes 963
9 Storage Attributes This section provides details about the Storage attribute groups and objects. Topics: • • • • Storage.Controller Storage.Enclosure Storage.PhysicalDisk Storage.VirtualDisk Storage.Controller The following sections provide information about the objects in this group Storage.Controller. Storage.Controller.AutoConfigBehavior (Read or Write) Description Indicates the current value of the auto config behavior of the controller.
Default Value None Write Privilege Server Configuration License Required Dependency A battery should be present on the controller. Storage.Controller.Check Consistency Mode (Read or Write) Description Check Consistency feature is used to verify the accuracy of the redundant (parity) information. Legal Values ● Normal ● Stop on Error Default Value Normal Write Privilege Server Configuration License Required Dependency None Storage.Controller.
Legal Values ● None ● Local Key Management ● Dell Key Management Default Value None Write Privilege None License Required Dependency If set to 'Local Key Management' you must set KeyID and NewControllerKey. Storage.Controller.Controller Rekey (Read or Write) Description This pseudo attribute represents whether a rekey operation needs to be performed on the RAID controller.Configurable via XML configuration feature only.
Storage.Controller.Current Controller Mode (Read Only) Description This indicates controllers current personaility mode , which could be RAID or Non-RAID. PERC9 supports RAID and HBA.Starting PERC 10, modes supported are RAID and Enhanced HBA. PERC 11 and above controllers will only support RAID mode. Legal Values ● RAID ● HBA ● Enhanced HBA Default Value None Write Privilege None License Required Dependency Controller needs to support. Storage.Controller.
Default Value Disabled Write Privilege None License Required Dependency None Storage.Controller.Key identifier (Read Only) Description This attribute represents the controller key identifier for Local Key Management or Dell Key Management controller encryption modes. Configurable via XML configuration feature only.
Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Controller.Maximum Spans in Virtual Disk (Read Only) Description This attribute represents the maximum number of spans in a Virtual Disk, as supported by the controller. Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Controller.
Write Privilege None License Required Dependency Applicable only if 'RAIDrekey' is set to True Storage.Controller.Patrol Read Iterations (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Controller.Patrol Read Mode (Read or Write) Description Patrol Read is a feature for identifying disk errors in order to avoid disk failures and data loss or corruption.
License Required Dependency None Storage.Controller.Rebuild Rate (Read or Write) Description The Rebuild Rate is the percentage of the system's resources dedicated to rebuilding a failed disk when a rebuild is necessary. Legal Values None Default Value 100 Write Privilege Server Configuration License Required Dependency None Storage.Controller.
Write Privilege None License Required Dependency Controller needs to support. Storage.Controller.Spin Down Idle Time (Read Only) Description Spindown idle time is the amount of time in seconds an uncofigured or hotspare can be idle before being spinned down by the controller. Legal Values None Default Value 30 Write Privilege None License Required Dependency None Storage.Controller.
Dependency None Storage.Controller.Supported Initialization types (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Controller.Supported RAID Levels (Read Only) Description This attribute provides a list of RAID levels supported by the controller. Legal Values ● ● ● ● ● ● Default Value None Write Privilege None RAID-0 RAID-1 RAID-5 RAID-10 RAID-50 RAID-60 License Required Dependency None Storage.Controller.
License Required Dependency None Storage.Enclosure This group contains the attributes that provides details about Storage.Controller NOTE: AssetName and AssetTag are applicable only for external enclosures. NOTE: If the enclosure is in Failed state, the information about the slots and their occupancy is not displayed. Storage.Enclosure.Asset Tag (Read Only) Description Displays the Asset Tag information for the enclosure.
Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Enclosure.Enclosure Current Configuration Mode (Read Only) Description This indicates enclosures current configuration mode setting Legal Values ● Unified Mode ● Split Mode Default Value None Write Privilege None License Required Dependency Backplane needs to support it. Storage.Enclosure.
Dependency None Storage.Physical Disk.Certified (Read or Write) Description Indicates if the drive is DELL certified or not. Legal Values ● Unknown|Yes|No Default Value Unknown Write Privilege None License Required Dependency None Storage.Physical Disk.EncryptionProtocol (Read or Write) Description The security protocol supported by the drive Legal Values ● None ● TCG Enterprise SSC ● TCG Enterprise Opal Default Value None Write Privilege None License Required Dependency None Storage.
Storage.Physical Disk.Media Type (Read Only) Description The drive media could be rotational (Hard Disk Drive) or solid state (SSD). This attribute indicates the drive media type. Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Physical Disk.Negotiated Speed (Read Only) Description Negotiated Speed shows the speed of data transfer that the disk negotiated while spinning up and upon initial communication with the controller.
Storage.Physical Disk.PCIeCapableLinkWidth (Read or Write) Description The maximum PCIe Link Width supported by the device Legal Values ● None|x4 Default Value None Write Privilege None License Required Dependency None Storage.Physical Disk.PCIeNegotiatedLinkWidth (Read or Write) Description The negotiated PCIe link width of the device Legal Values ● None|x1|x2|x4 Default Value None Write Privilege None License Required Dependency None Storage.Physical Disk.
Storage.Physical Disk.T10PI capable (Read Only) Description Legal Values None Default Value None Write Privilege None License Required Dependency None Storage.Physical Disk.UnmapCapability (Read or Write) Description This attribute applies to Physical Disk and Virtual Disk Legal Values ● Not Capable ● Capable Default Value Not Capable Write Privilege None License Required Dependency None Storage.Physical Disk.
Default Value Update Write Privilege None License Required Dependency None Storage.Virtual Disk.Cachecade State (Read Only) Description This attribute represents the cachecade state of the virtual disk. It can be modified to create a cachecaded virtual disk using XML configuration feature. Configurable via XML configuration feature only.
Storage.Virtual Disk.Initialization Operation (Read or Write) Description This pseudo attribute represents initialization configuration operation to be performed on the virtual disk via XML configuration feature. Configurable via XML configuration feature only. Legal Values ● None ● Fast Default Value None Write Privilege None License Required Dependency Applicable only if RAIDaction is 'Update' or 'Create' Storage.Virtual Disk.
Storage.Virtual Disk.RAID Level (Read Only) Description This indicates the type of RAID level on the virtual disk. Configurable via XML configuration feature only. Legal Values ● ● ● ● ● ● ● Default Value None Write Privilege None RAID RAID RAID RAID RAID RAID RAID 0 1 5 6 10 50 60 License Required Dependency Applicable only if RAIDaction is 'Create' Storage.Virtual Disk.
Dependency Applicable only if RAIDaction is 'Create' Storage.Virtual Disk.Span Length (Read Only) Description This indicates the number of physical disks per span on a virtual disk.Configurable via XML configuration feature only. Legal Values None Default Value None Write Privilege None License Required Dependency Applicable only if RAIDaction is 'Create' Storage.Virtual Disk.Stripe Size (Read Only) Description This indicates the stripe size of the virtual disk.
10 System Attributes This section provides details about the System attribute groups and objects. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • System.AcquisitionInfo System.Backplane System.ChassisInfo System.CustomAsset System.DepreciationInfo System.Diagnostics System.ExtWarrantyInfo System.IdleServerDetection System.LCD System.LeaseInfo System.MaintenanceInfo System.OpenIDConnectServer System.OutsourceInfo System.OwnerInfo System.PCIeSlotLFM System.PowerHistorical System.
Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.AcquisitionInfo.Expensed (Read or Write) Description Determines whether the cost of the system was subtracted from the budget of a particular person or department in the purchasing company. Legal Values ● Yes-0 ● No-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.AcquisitionInfo.
Dependancy None System.AcquisitionInfo.PurchaseDate (Read or Write) Description Date the transaction for acquiring the system was completed. Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.AcquisitionInfo.Vendor (Read Only) Description Company who sold the system to the purchaser. Legal Values ● String of up to 64 ASCII characters.
System.Backplane.BackplaneBusMode (Read Only) Description Enclosure serial interface type, either SGPIO or I2C Legal Values ● Unknown-0 ● I2C-1 ● SGPIO-2 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.Backplane.BackplaneSplitMode (Read or Write) Description Enclosure split mode setting Legal Values ● Integral values from 0 to 255 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.
System.ChassisInfo.ChassisModel (Read Only) Description Specifies the chassis model. Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependency None System.ChassisInfo.ChassisName (Read Only) Description Specifies the chassis name Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ChassisInfo.
System.ChassisInfo.ConnectionState (Read Only) Description Specifies the chassis connection state. Legal Values ● Unknown—0 ● Disconnected/Offline—1 ● Connected/Ready—2 Default Value Unknown Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ChassisInfo.FirmwareVersion (Read Only) Description Specifies the chassis firmware version. Legal Values ● String of up to 255 ASCII characters.
System.CustomAsset.Value (Read or Write) Description Custom Asset value Legal Values ● String of up to 255 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.DepreciationInfo This group contains the attributes that provides details about System.DepreciationInfo. System.DepreciationInfo.Duration (Read or Write) Description Displays the duration for which the depreciation value is being calculated.
System.DepreciationInfo.Percentage (Read or Write) Description Indicates the portion of 100 that an asset is devalued or depreciated. If the duration of depreciation is 5 years, and the method is straight line, then the percentage is 20 percent. Legal Values ● String of up to 32 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.Diagnostics This group contains the attributes that provides details about system diagnostics. System.
License Required iDRAC Basic Dependancy None System.ExtWarrantyInfo.Provider (Read or Write) Description Displays the name of the business that is providing warranty service to the system owner. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ExtWarrantyInfo.StartDate (Read or Write) Description Displays the date that extended warranty service begins.
● Idle-1 Default Value 0 Write Privilege Not Applicable License Required iDRAC Datacenter Dependancy None System.IdleServerDetection.IdleServerThreshold (Read or Write) Description Idle server detection threshold in % Legal Values ● Integral values from 0 to 50 Default Value 20 Write Privilege Configure iDRAC License Required iDRAC Datacenter Dependancy None System.IdleServerDetection.
System.LCD.Configuration (Read or Write) Description Current LCD configuration. If this is set to User Defined, the User defined string will be displayed on the LCD.
System.LCD.FrontPanelLocking (Read or Write) Description Sets LCD button interface to Full-Access;View-Only; or No access (Locked) Legal Values ● Full-Access-0 ● View-Only-1 ● Locked-2 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None System.LCD.HideErrs (Read or Write) Description Hide or unhide errors displayed on LCD screen.
System.LCD.NumberErrsHidden (Read Only) Description The number of hidden LCD active errors Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None System.LCD.NumberErrsVisible (Read Only) Description The number of visible LCD active errors Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None System.LCD.
Legal Values ● String of up to 62 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy System.LCD.Configuration has to be set to 'User Defined' mode System.LCD.vConsoleIndication (Read or Write) Description Virtual Console Indication Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.
Legal Values ● String of up to 32 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.LeaseInfo.Lessor (Read or Write) Description Displays the name of the business entity that is leasing the system to the user. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.LeaseInfo.
Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.MaintenanceInfo.Provider (Read or Write) Description The business entity that provides maintenance on a system. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.MaintenanceInfo.
Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.OpenIDConnectServer.ClientURI (Read Only) Description Client registration URI Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.OpenIDConnectServer.DiscoveryURL (Read or Write) Description Discovery URL Legal Values ● String of up to 1024 ASCII characters.
System.OpenIDConnectServer.Name (Read or Write) Description Server name Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.OpenIDConnectServer.RegistrationDetails (Read or Write) Description Registration details Legal Values ● String of up to 1024 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.
System.OutsourceInfo.ProviderFee (Read or Write) Description Defines any additional fee invoiced by the outsource service provider. Legal Values ● String of up to 32 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.OutsourceInfo.ServiceFee (Read or Write) Description Amount of money paid for either the service contract or for corrective action on a specific problem component. Legal Values ● String of up to 32 ASCII characters.
System.OwnerInfo.InsComp (Read or Write) Description The company that insures the system against theft or other loss. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.OwnerInfo.OwnerName (Read or Write) Description The individual or business entity that holds legal title to the system. Legal Values ● String of up to 64 ASCII characters.
System.PCIeSlotLFM.CardType (Read Only) Description Type of PCIe card installed Legal Values ● String of up to 512 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.PCIeSlotLFM.
Legal Values ● Integral values from 0 to 127 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.PCIeSlotLFM.SlotState (Read Only) Description PCIe slot physically exists Legal Values ● Not-Defined-0 ● Defined-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.PCIeSlotLFM.
System.QuickSync.Access (Read or Write) Description Sets QuickSync access permission Legal Values ● Disabled-0 ● Read-only-1 ● Read-write-2 Default Value 2 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy System.QuickSync.Presence has to be Absent or Present System.QuickSync.
System.QuickSync.ReadAuthentication (Read or Write) Description Enables or disables QuickSync read authentication to the server Legal Values ● Disabled-0 ● Enabled-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy System.QuickSync.Presence has to be Absent or Present System.QuickSync.
Legal Values ● Integral values from 0 to 1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerInfo This group contains the attributes that provides details about system server info. System.ServerInfo.NodeID (Read Only) Description Specifies the system node ID. Legal Values ● String of up to 124 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerInfo.
System.ServerInfo.ServiceTag (Read Only) Description Specifies the system service tag. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerOS This group contains the attributes that provide details about system server OS. NOTE: system.serveros.productkey value is shown only if OA3.x is available, which may be available with future generations of MSFT and newer version of Windows Server OS.
System.ServerOS.OSVersion (Read Only) Description Server OS Version Legal Values ● String of up to 254 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerOS.ProductKey (Read Only) Description Windows OS Product Key associated with the server Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerOS.
System.ServerPwr.ActivePowerCapVal (Read Only) Description Set the Active Power Cap value Legal Values ● Integral values from 0 to 32767 Default Value 32767 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependancy None System.ServerPwr.
Default Value 32767 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependancy None System.ServerPwr.PSPFCEnabled (Read or Write) Description Enable the Power Supply Power Factor Correction Legal Values ● Disabled-0 ● Enabled-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependancy None System.ServerPwr.PSRapidOn (Read or Write) Description Enable the Power Supply Rapid On.
License Required iDRAC Express or iDRAC Enterprise Dependancy None System.ServerPwrMon This group contains the attributes that provide details about system server power monitor. System.ServerPwrMon.AccumulativePower (Read Only) Description Total power in energy consumed by server from start time. Legal Values ● Integral values from 0 to 2147483647 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerPwrMon.
License Required iDRAC Basic Dependancy None System.ServerPwrMon.MinPowerTimeStr (Read Only) Description The time when minimum power is recorded. Legal Values ● String of up to 128 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerPwrMon.
System.ServerPwrMon.PeakPowerStartTime (Read Only) Description Start of time period for which peak power is recorded. Legal Values ● Integral values from 0 to 2147483647 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerPwrMon.PeakPowerStartTimeStr (Read Only) Description The start time when peak power is recorded. Legal Values ● String of up to 128 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerPwrMon.PowerConfigReset (Read or Write) Description Resets the power statistics starting time. (Write only). Legal Values ● ● ● ● ● Default Value 0 Write Privilege Configure iDRAC None-0 ClrCumulaPowerAndTime-1 ClrPeaKValueAndTIme-2 ClrAll-3 ClrPeakAndCumulaValue-4 License Required iDRAC Basic Dependancy None System.ServerTopology NOTE: The System.Location group is deprecated and replaced with System.
System.ServerTopology.DataCenterName (Read or Write) Description The data center the system is located in. Legal Values ● String of up to 128 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServerTopology.RackName (Read or Write) Description Name of the rack on which the system is located. Legal Values ● String of up to 128 ASCII characters.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServiceContract This group contains the attributes that provides details about System.ServiceContract. System.ServiceContract.Renewed (Read or Write) Description Whether the service contract was renewed or not (Yes or No). Legal Values ● Yes-0 ● No-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ServiceContract.
System.Storage.AvailableSpareAlertThreshold (Read or Write) Description Displays the system level user configured threshold value for available spare value of the SSD devices connected to system. Legal Values ● Integral values from 1 to 99 Default Value 10 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.Storage.
Dependancy None System.SupportInfo.Outsourced (Read or Write) Description Indicates whether you have contracted with an outside business entity to provide technical support for your system. Legal Values ● Yes-0 ● No-1 Default Value 1 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.SupportInfo.Type (Read or Write) Description Indicates whether a support request is for a problem with your system's network connectivity or with a particular system component.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.SystemInfo.PrimaryUser (Read or Write) Description Text that provides the name for the person responsible for managing the system. Legal Values ● String of up to 64 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.SystemInfo.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalConfig.CriticalEventGenerationInterval (Read or Write) Description Indicates time interval in days for critical events to be generated Legal Values ● Integral values from 0 to 365 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalConfig.
Write Privilege Not Applicable License Required iDRAC Basic Dependancy Not shown if system.embedded.1#thermalsettings.1#systemCFMsupport is not supported. System.ThermalConfig.ValidFanConfiguration (Read Only) Description Valid Fan Configuration Legal Values ● No-0 ● Yes-1 ● NotApplicable-2 Default Value 2 Write Privilege Server Configuration License Required iDRAC Basic Dependancy None System.ThermalHistorical This group contains the attributes that provide details about System.
● 65-5 ● 70-255 Default Value 255 Write Privilege Configure iDRAC License Required iDRAC Datacenter Dependancy Feature must be supported to set the value. System.ThermalSettings.AirExhaustTempSupport (Read Only) Description Specifies if the Average Air Exhaust Temperature is supported Legal Values ● Not Supported-0 ● Supported-1 Default Value 0 Write Privilege Server Configuration License Required iDRAC Datacenter Dependancy None System.ThermalSettings.
System.ThermalSettings.CurrentSystemProfileValue (Read Only) Description Displays current system profile value Legal Values ● String of up to 32 ASCII characters. Default Value None Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalSettings.DriveTemperaturePolling (Read or Write) Description Specifies if drive temperature polling is enabled, disabled, or set to default for drives attached to an HBA.
System.ThermalSettings.FanSpeedMaxOffsetVal (Read Only) Description Specifies the Fan Speed Max Offset Value Legal Values ● Integral values from 0 to 65535 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalSettings.FanSpeedMediumOffsetVal (Read Only) Description Specifies the Fan Speed Medium Offset Value NOTE: This attribute is platform dependent.
License Required iDRAC Datacenter Dependancy Feature must be supported to set the value. System.ThermalSettings.MaximumPCIeInletTemperatureLimitSup port (Read Only) Description Defines if the Maximum PCIe Inlet Temperature Limit configuration is supported. Legal Values ● Not Supported-0 ● Supported-1 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Datacenter Dependancy None System.ThermalSettings.
Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalSettings.PCIeSlotLFMSupport (Read Only) Description Specifies if the PCIe LFM feature is supported Legal Values ● Not Supported-0 ● Supported-1 Default Value 0 Write Privilege Server Configuration License Required iDRAC Datacenter Dependancy None System.ThermalSettings.ReportConfigError (Read or Write) Description Specifies if unsupported configuration errors should be reported.
Write Privilege Configure iDRAC License Required iDRAC Datacenter Dependancy Feature must be supported to set the value. System.ThermalSettings.SystemCFMSupport (Read Only) Description Specifies if the System CFM is supported Legal Values ● Not Supported-0 ● Supported-1 Default Value 0 Write Privilege Server Configuration License Required iDRAC Datacenter Dependancy None System.ThermalSettings.SystemExhaustTemperature (Read Only) Description Indicates the current system exhaust temperature.
System.ThermalSettings.TargetExhaustTemperatureLimit (Read Only) Description Indicates the current effective target exhaust temperature limit. Legal Values ● Integral values from 0 to 127 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.ThermalSettings.ThermalProfile (Read or Write) Description Specifies the Thermal Profile NOTE: Restart the system to activate the power and thermal settings.
System.WarrantyInfo This group contains the attributes that provides details about System.WarrantyInfo. System.WarrantyInfo.Cost (Read or Write) Description The total cost of the warranty service on a system. Legal Values ● String of up to 32 ASCII characters. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None System.WarrantyInfo.Duration (Read or Write) Description The number of days or months that the warranty is to be in force.