Technical Data 1.888.KEITHLEY (U.S. only) www.keithley.
Multimeter/Switch Systems Integra Series Introduction The Integra Series of 61⁄2-digit Multimeter/Switch systems blends Keithley’s high performance DMM technology, switching expertise, and data acquisition knowledge into compact, affordable, easy-to-use packages. This technical data booklet provides a comprehensive overview of the systems and includes detailed specifications. There are three Integra systems: the Model 2700, 2701, and 2750.
Integra Series Multimeter/Switch Systems 1.888.KEITHLEY NPLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Line Cycle Synchronization . . . . . . . . . . . . . . . . . . . . . . . . .14 Autozero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Low Ohms Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Offset Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Integra Series Multimeter/Switch Systems Model 2700 Measure the ratio or average of two input channels. View a channel of interest without interrupting a scan by using the Channel Monitor feature. Built-in linearization for thermocouples, RTDs, and thermistors. Front panel input jacks simplify manual probing, troubleshooting, and calibration. Built-in signal conditioning with 1000V isolation simplifies system configuration and ensures good measurements.
Integra Series Multimeter/Switch Systems Model 2701 Built-in signal conditioning and statistical analysis is configurable per channel for maximum flexibility. Its familiar DMM-like front panel scheme makes the Model 2701 easy to use on the bench or in the rack. Select or change functions with the press of a button. Large memory buffer (450,000 readings) for storing data without tying up the network.
Integra Series Multimeter/Switch Systems Model 2750 Use mX+b or 1/x % scaling to convert sensor/transducer outputs directly into engineering units. View slot capacity and channel closure status from front panel. Built-in independently programmable alarm limits per channel. Front panel input jacks simplify manual probing, troubleshooting, and calibration. Open lead detection protects against false readings due to lead disconnections.
Multimeter/Switch Systems Integra Series Measurement Ranges for the Integra Series Systems DC Voltage AC Voltage DC Current 1m 1 100nV 100nV 10nA AC Current Frequency 1µA Period Resistance (2-Wire) 2µs 10µΩ 1µΩ 1k 1M 3A 3A 3Hz Resistance (4-Wire) 1G 1000V 750V 500kHz 333ms 120MΩ 120MΩ Logarithmic scale –500 Temperature–RTD Temperature–TC Temperature–Thermistor 0 –200°C –200°C –80°C 500 1000 1500 2000 630°C 1820°C 150°C Linear scale Model 2750 only Figure 2.
Multimeter/Switch Systems Integra Series Module Selector Guide This selector guide may prove helpful in identifying the best module for a specific application. Install up to five modules at a time in the Model 2750 mainframe or two modules in the Model 2700 or 2701 mainframe. Switch/Control Module Capabilities # Analog Module Inputs Configuration Type of Connector Max. Voltage Max.
Integra Series Multimeter/Switch Systems Channel Configuration Capabilities Channel Configuration Capabilities — Scanning Capabilities • Measurement functions: An Integra system can measure many different parameters: DC voltage, DC current, AC voltage, AC current, 2-wire Ω, 4-wire Ω, voltage clamped Ω (2750 only), temperature (using thermocouples, RTDs, and thermistors), frequency, period, and continuity.
Integra Series Multimeter/Switch Systems • Scan interval: The user can set the interval after which each succeeding scan will begin. Scan intervals can be set anywhere from 0 to 99 hours in increments of 1ms. Scanning Capabilities — Choice of Communication Interfaces • Scan sequence/omitting channels: In addition to scanning in numerical sequence, the system can be programmed to skip any channels that are not required for a particular test.
Integra Series Multimeter/Switch Systems Triggering and I/O Capabilities Trigger sources Any of the following sources can be used for triggering a reading or scan sequence: A. Immediate: An Integra Series system self-triggers automatically. This default method is the simplest way to take a measurement on a single channel. B Triggering and I/O Capabilities B. An external trigger is received via the Trigger Link connector. Triggering through Trigger Link is very precise (<0.
Triggering and I/O Capabilities — On-board Data Storage Integra Series Multimeter/Switch Systems Alarm Limits/Digital Outputs The digital output lines can trigger external alarms without the need for a PC connection. The instrument can be programmed to provide alarms when any pre-set limits are breached. Limits can be applied to all measurement functions except continuity, which has its own alarm beeper. The limit test is performed after “mX + b” and math operations.
All current set-up information for individual channels and the mainframe is battery backed and the measurement data is stored in the non-volatile memory. Therefore, while the instrument is switched off, the configuration for each channel is saved in the memory, then automatically recalled when the product is switched on again.
Digital Filtering — NPLC — Line Cycle Synchronization — Autozero — Low Ohms Measurement Multimeter/Switch Systems Integra Series Digital Filtering For each major measurement function, users can employ either averaging or advanced digital filtering to reduce noise and increase the effective resolution. Averaging Filter The averaging filter operates over a range of from two to 100 readings. All readings included in the filter range are weighted equally.
Multimeter/Switch Systems Offset Compensation — Voltage Limit/Dry Circuit Ohms — Temperature Measurements Integra Series Offset Compensation For more accurate low resistance measurements, all Integra systems provide the offset compensation mode to eliminate errors from the thermoelectric EMF effects (VEMF). During the measurement cycle, the built-in ohms current source is turned off, then turned on again, and the resulting EMF error is automatically subtracted.
Integra Series Multimeter/Switch Systems Cold Junction Compensation Methods Thermocouple measurements always require that the temperature be known at the point where the thermocouple is connected to the instrument. This connection point is known as the “cold junction.” The Integra systems support three different methods for including this “cold-junction” temperature in the temperature measurements.
Integra Series Multimeter/Switch Systems Start-Up Software This free TestPoint runtime offers basic datalogging capabilities that can get a system “up & running” almost immediately. With just a few clicks of the mouse, this software can confirm the system’s hardware, wiring, communications, and software drivers are installed and operating correctly. It can also configure instrument functions and perform simple data acquisition tasks.
Integra Series Multimeter/Switch Systems Datalogging/Data Acquisition Software Custom Application Development with VISA Based IVI Driver Software ExceLINX-1A SWITCH/MEASURE SYSTEMS For advanced datalogging tasks, this powerful and economical add-in utility for Microsoft® Excel makes it simple to acquire data from the Integra Series instrument directly into Excel, then employ Excel’s graphic, charting, and analysis capabilities to turn that data into useful information.
Multimeter/Switch Systems Integra Series Specifications Integra Series Specifications are subject to change without notice. 1.888.KEITHLEY (U.S. only) www.keithley.com A G R E A T E R M E A S U R E O F C O N F I D E N C E SWITCH/MEASURE SYSTEMS Download the latest specs from www.keithley.com.
Multimeter/Switch Systems Integra Series Mainframes DC CHARACTERISTICS1 CONDITIONS: MED (1 PLC)2 or 10 PLC or MED (1 PLC) with Digital Filter of 10 FUNCTION Voltage 11 Integra Series Specifications Resistance 6, 8 Dry Circuit Resistance 21, 24 Continuity (2W) Current SWITCH/MEASURE SYSTEMS mV V V V V5 Ω24 Ω24 Ω kΩ kΩ kΩ MΩ 23 MΩ 7, 23 MΩ 7, 23 Ω Ω Ω kΩ kΩ mA mA A A 0.1 1.0 10 100 1 1 10 100 1 10 100 1.0 10 100 1 10 100 1 100 10 100 1.
Mainframes Multimeter/Switch Systems DC SPEED vs. NOISE REJECTION Rate Filter Readings/s12 10 50 0.1 (0.08) 1 Off 15 (12) 0.1 Off 500 (400) 0.01 Off 2500 (2000) 0.002 Off 3500 (2800) RMS Noise 10V Range Digits 2700,2750 2701 NMRR CMRR 14 6.5 < 1.2 µV < 2.5 µV 110 dB13 140 dB 6.5 < 4 µV < 6 µV 90 dB13 140 dB 5.5 < 22 µV < 40 µV — 80 dB 4.5 < 150 µV < 300 µV — 80 dB 3.5 — < 1 mV — 60 dB DC NOTES 1. 20% overrange except on 1000V and 3A. 2.
Multimeter/Switch Systems Integra Series Mainframes AC SPECIFICATIONS1 Accuracy: ±(% of reading + % of range), 23°C ± 5°C Function Voltage 2 Current 2 Range 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 750.000 V Resolution 0.1 µV 1.0 µV 10 µV 100 µV 1.0 µV 1.000000 A 3.00000 A 14 1.0 µA 10 µA Calibration Cycle 90 Days (all ranges) 1 Year (all ranges) 3 Hz–10 Hz 0.35 + 0.03 10 Hz–20 kHz 0.05 + 0.03 20 kHz–50 kHz 0.11 + 0.05 50 kHz–100 kHz 0.6 + 0.08 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.
Integra Series Mainframes Multimeter/Switch Systems 1.888.KEITHLEY TRIGGERING AND MEMORY: Window Filter Sensitivity: 0.01%, 0.1 %, 1%, 10%, or Full-scale of range (none). Reading Hold Sensitivity: 0.01%, 0.1 %, 1%, or 10% of reading. Trigger Delay: 0 to 99 hrs (1ms step size). External Trigger Delay: <2ms (2700), <1ms (2701, 2750). External Trigger Jitter: <1ms (2700), <500µs (2701), <500µs (2750). Memory Size: 55,000 readings (2700), 450,000 readings (2701), 110,000 readings (2750).
Integra Series Modules Multimeter/Switch Systems 7700 20-CHANNEL DIFFERENTIAL MULTIPLEXER W/AUTOMATIC CJC FEATURES Model 7700 Specifications • 20 channels for general-purpose measurements, plus two channels to measure current. • 2- or 4-wire measurement. • Oversize screw terminal connection blocks are standard for easier connections. • Automatic CJC sensors on the scanner card mean there are no other accessories are required to make thermocouple temperature measurements.
Integra Series Modules Multimeter/Switch Systems 7701 LOW-VOLTAGE 32-CHANNEL DIFFERENTIAL MULTIPLEXER FEATURES Model 7701 Specifications • Configurable for 32 channels of differential measurements, with up to 16 channels of 4-pole measurements. • Configurable for 32 channels of common-side 4-wire ohms. • Configurable as two independent banks of multiplexers. • Two female D-shell connectors are standard for secure hook-up and quick teardown. • 150V, 1A capacity for voltage channels; 60W, 125VA.
Integra Series Modules Multimeter/Switch Systems 7702 40-CHANNEL DIFFERENTIAL MULTIPLEXER FEATURES • There are 40 channels for general-purpose measurement, plus 2 channels to measure current. • 2- or 4-wire measurement. • Oversize screw terminal connection blocks are standard for easier connection. • Configurable as two independent banks of multiplexers. • 300V, 1A capacity for voltage channels; 60W, 125VA. • 3A capacity for current channels. • Relay closures stored in on-board memory.
Integra Series Modules Multimeter/Switch Systems 7703 32-CHANNEL HIGH SPEED DIFFERENTIAL MULTIPLEXER FEATURES Model 7703 Specifications • • • • There are 32 channels for general purpose measurement. Relay actuation time of less than 1ms for high-speed scanning. 2 or 4 wire measurement. Two 50-pin female “D-sub” connectors are standard for secure hook-up and quick teardown. Configurable as two independent banks of multiplexers. Reed relay based design with 300 volt, 500mA; 10VA.
Integra Series Modules Multimeter/Switch Systems 7705 40-CHANNEL CONTROL MODULE FEATURES • 40 channels designed for controlling power to the DUT, switching loads, controlling light indicators and relays, etc. • Two 50-pin female “D-sub” connectors are standard for secure hook-up and quick teardown. • 300V, 2A capacity. • Two mating connectors with solder cup pins (Model 7788) are supplied. • Relay closures stored in on-board memory.
Integra Series Modules Multimeter/Switch Systems 7706 ALL-IN-ONE I/O MODULE FEATURES Input • 20 channels of analog input (w/automatic CJC) for general-purpose measurement. • 16 channels of digital output. • Event counter/totalizer can monitor and control system components, such as fixturing, limit switches, pass/fail indicators, external voltage sources, loads, door closures, revolutions, etc., while performing mixed signal measurement. • 300V, 1A capacity; 60W, 125VA maximum.
Integra Series Modules Multimeter/Switch Systems 7707 MULTIPLEXER-DIGITAL I/O MODULE GENERAL Model 7707 Specifications 10 CHANNELS: 10 channels of 2-pole relay input. All channels configurable to 4-pole. RELAY TYPE: Latching electromechanical. ACTUATION TIME: <3ms. FIRMWARE: Specified for Model 2700 rev. B03, 2701 rev. A01, and 2750 rev. A01 or higher. CAPACITY: Model 2700: (1) 7707 and (1) 77XX, except 7706. Model 2701: Any combination of 77XX modules. Model 2750: (4) 7707 and (1) 77XX, except 7706.
Integra Series Modules Multimeter/Switch Systems 7708 40-CHANNEL DIFFERENTIAL MULTIPLEXER MODULE FEATURES • • • • • • • 40 differential channels for general-purpose measurements. 2- or 4-wire measurements. Oversize screw terminal connection blocks are standard for easier connection. 300V, 1A capacity for voltage channels; 60W, 125VA. Configurable as two independent banks of multiplexers. Built-in CJC sensors automatically linearize thermocouples. Relay closures stored in on-board memory.
Integra Series Modules Multimeter/Switch Systems 7709 6×8 MATRIX MODULE FEATURES • Automatic 2- or 4-wire connection to DMM • 6 row×8 column matrix • Two female “D-sub” connectors are standard for secure hook-up and quick teardown. • 300V, 1A capacity. • Two mating IDC connectors for ribbon cable are supplied. • Relay closures stored in on-board memory. Model 7709 Specifications GENERAL MATRIX CONFIGURATION: 6 rows × 8 columns. CONTACT CONFIGURATION: 2 pole Form A.
Multimeter/Switch Systems Integra Series Modules 7710 20-CHANNEL SOLID STATE/LONG-LIFE DIFFERENTIAL MULTIPLEXER W/AUTOMATIC CJC FEATURES Model 7710 Specifications • Solid-state relays for long life and low maintenance (100 times longer life than mechanical relays) • Higher scanning speeds of up to 500 channels per second • Automatic CJC with no extra accessories required for thermocouple measurements • Removable screw terminals offer simple, quick connections • 20 channels for general purpose measuremen
Multimeter/Switch Systems Integra Series Modules 7711 2GHz 50Ω RF MODULE FEATURES Model 7711 Specifications • • • • • • Outstanding signal routing performance to 2GHz Dual 1×4 configuration Rear panel connections On-board switch closure counter On-board S-parameter storage Switch up to 60VDC AC PERFORMANCE (End of Life) For Zload = Zsource = 50Ω <100 MHz 500 MHz Insertion Loss <0.4 dB <0.6 dB Max. VSWR Max. <1.1 <1.2 Ch-Ch Crosstalk1 –85 dB –65 dB Max. 1 2 1 GHz <1.0 dB 1.5 GHz <1.2 dB 2 GHz <2.
Multimeter/Switch Systems Integra Series Modules 7712 3.5GHz 50Ω RF MODULE FEATURES • • • • • 3.5GHz bandwidth Dual 1×4 configuration Rear panel SMA connections On-board switch closure counter On-board S-parameter storage For Zload = Zsource = 50Ω <500 MHz Insertion Loss <0.5 dB MAX VSWR MAX <1.15 Ch-Ch Crosstalk1 –75 dB MAX 1 2 1 GHz <0.65 dB 2.4 GHz <1.1 dB 3.5 GHz <1.3 dB <1.2 –70 dB <1.452 –50 dB <1.
Multimeter/Switch Systems SWITCH/MEASURE SYSTEMS System Configuration Examples Integra Series 36 1.888.KEITHLEY (U.S. only) www.keithley.
Multimeter/Switch Systems Integra Series Simple Computer to Single Instrument Control GPIB Ethernet Maximum Distance ~15 m† 2m Maximum Speed 115.2 kb/s (2701) 19.2 kb/s (2700, 2750) 1 MB/s Hardwired: 100 m Wireless: >16 km 100 Mb/s Cable Type Null modem cable Keithley Model 7009-5 Standard GPIB cable Keithley Model 7007-* RJ-45 crossover cable † RS-232 maximum distance is heavily dependent on the baud rate setting.
Multimeter/Switch Systems Integra Series Thermocouple Configuration Example Using Internal CJC Thermocouple connections Thermocouple Configuration Example Using External CJC Thermocouple connections HI Externally supplied cold junction reference* *Connect Thermistor or RTD (see Note) HI Channel 1 System Configuration Examples Channel 1 LO LO (Channels 2–19) Thermocouple HI HI Channel 2 Channel 20 LO LO (Channels 3–39) NOTE: The red lead is the LO signal on all thermocouples.
Multimeter/Switch Systems Integra Series 7708 Configuration Examples (continued) Using internal DMM and external instruments HI Ch. 45 Internal DMM LO Card Input Ch. 1 . . . Scope LO See Model 7708 specifications. Channel 43 .....Open Channel 44 .....Open Channel 45 .....Closed Ch. 20 DUT Ch. 43 HI Card Sense Counter Ch. 21 . . . LO Ch. 40 NOTE: This configuration example can be duplicated with the 7700, 7701, 7702, 7703, 7706, 7707, and 7708 modules.
Multimeter/Switch Systems Integra Series 7705 Configuration Examples (continued) Variable AC line/load test connections System Configuration Examples Model 7705 IN 1 OUT 1 IN 2 OUT 2 DUT 90% Load Resistor 10% Load Resistor AC Source LO AC Source HI IN 4 IN 3 Model 7705 OUT 3 OUT 4 CAUTION: Maximum switch current is 2A. Source is impedance limited from mains (Safety Category I signals).
Integra Series Multimeter/Switch Systems 7705 Configuration Examples (continued) 7705 independent switch and 7701 multiplexer example 7705 – DUT 1 DC to DC Converter Input Power . . . + DUT 16 DC to DC Converter 48VDC 48VDC – Output Ch. 1 Ch. 2 Ch. 31 Ch. 32 System Configuration Examples + Output 7701 Screw Terminals HI HI Ch. 35 Ch. 1 LO LO Chs. 1–32 To Internal DMM HI Ch. 2 LO . . . Ch. 16 See Model 7701 specifications. Channel 33 .....Closed Channel 34 .....Open Channel 35 ....
Multimeter/Switch Systems Integra Series Analog Output and Digital I/O Examples Typical digital output w/external power supply SWITCH/MEASURE SYSTEMS System Configuration Examples Digital Output The 7706 module has two non-isolated 8-bit output ports that can be used for outputting digital patterns. The two ports can be combined to output a single 16-bit word or a dual 8-bit byte. A simplified diagram of a single output bit is shown here.
Multimeter/Switch Systems Integra Series Analog Output and Digital I/O Examples (continued) Connecting the Model 7707 Digital I/O module to industry standard solid-state relays (SSRs) to switch high VA (up to 980VA). Dig. I/O Ch. 11 DB-50 8 Dig. I/O Ch. 12 Dig. I/O Ch. 13 Dig. I/O Ch. 14 Industry Standard PB-24SM 24 SSR Baseboard . 50-Pin . Card Edge . SSR1 1. .. 8 1. .. 8 1 .. . 4 5. .. 8 1. .. 4 5. .. 8 8 SSR2 Cable User Supplied Switch or Sense SSR3 . . Optically .
Integra Series Multimeter/Switch Systems 7701 Configuration Example 7701 32-Channel common-side 4-wire Ohms configuration example D-Sub Connectors User Configurable Screw Terminals DMM Input HI User Installed Jumpers DUT1 *Common Side Bus System Configuration Examples DMM Sense HI Sense HI DUT2 Ch. 35 Input HI **Ch. 33 (Open) 2750 DMM DUT3 Sense LO Ch.
Multimeter/Switch Systems 1.888.KEITHLEY (U.S. only) www.keithley.
SWITCH/MEASURE SYSTEMS Integra Series 46 Multimeter/Switch Systems Specifications are subject to change without notice. All Keithley trademarks and trade names are the property of Keithley Instruments, Inc. All other trademarks and trade names are the property of their respective companies. Keithley Instruments, Inc. 28775 Aurora Road • Cleveland, Ohio 44139 • 440-248-0400 • Fax: 440-248-6168 1-888-KEITHLEY (534-8453) • www.keithley.