Specification
VICTORY range hoods
| Q1
6
B02 |
7
To calculate the length of the duct system you require, subtract the equivalent feet for each “Vent
piece” (Table Below) used in the system from the “Recommended maximum run” (Table Below).
The longest duct run that is acceptable (if completely straight) is 50 feet. The number of vent pieces
(elbow, transition, etc.) installed in your duct run will determine the maximum length the duct run can
be. Please refer to the example below:
Duct Run Calculation:
Recommended maximum run
6” round duct 50 ft
Vent piece deduction
Each 90º elbow used 9 ft
Each 45º elbow used 5 ft
Each 6” to 3/14 x 10” transition
used
7 ft
Side wall cap with damper 7 ft
Roof cap 7 ft
Duct Run Calcuation example:
One roof cap, two 90º elbows, and one 45º elbow
used:
7ft + 9ft + 9ft + 5ft = 30ft used.
The above vent pieces used are equivalent to 30ft
of a straight duct run. Subtract 30ft from the al-
lowable 50ft. The remaining distance of 20ft is the
longest that the straight ducting (in addition to the
vent pieces) can be.
CALCULATING VENT SYSTEM LENGTH
SPECIFICATIONS*
Body Stainless Steel / Sheet Metal
Power Rating
110-120V/60Hz (USA & Canada standard)
General Input Power 230W+# of Light x Votage of Light
Motor Input Power 230W
Motor Revolution 800 RPM (±10%) to 1300 RPM (±10%)
Levels Of Speed Control
4 Levels
Maximum Airow 900 CFM
Air Pressure 150 Pa (200 Pa Maximum)
Noise Level (dB / sone) Approximately 23.5 / 0.4 to 60 / 7.0 (Lowest to highest Speed)
Control Type
Somatosensory / touch / remote control
Illumination LED 3W 120V
Venting Size Top Vent, 6 inch Round
* Subject to change without notice,
Please visit https://itylza.com