3. SPECIFICATIONS AND TECHNI-
CAL DATA
1. NAME OF PARTS
2. TOOL SPECIFICATIONS
3. FASTENER SPECIFICATIONS
TOOL AIR FITTINGS:
This tool uses a 1/4" N.P.T. male plug. The inside diameter should
be .28" (7 mm) or larger. The fitting must be capable of discharging
tool air pressure when disconnected from the air supply.
RECOMMENDED OPERATING PRESSURE:
70 to 100 p.s.i. (5 to 7 bar). Select the operating air pressure within
this range for best fastener performance.
DO NOT EXCEED 120 p.s.i. (8 bar).
4. TECHNICAL DATA
1 NOISE
A-weighted single-event sound power level
------ LWA, 1s, d 93.1 dB
A-weighted single-event emission sound pressure level at
work station
------ LpA, 1s, d 89.3 dB
These values are determined and documented in accordance
to EN12549 : 1999.
2 VIBRATION
Vibration characteristic value = 4.4 m/s
2
These values are determined and documented in accordance
to ISO 8662-11.
This value is a tool-related characteristic value and does not
represent the influence to the hand-arm-system when using
the tool. An influence to the hand-arm-system when using
the tool will for example depend on the gripping force, the
contact pressure force, the working direction, the adjustment
of mains supply, the workpiece, the workpiece support.
5. APPLICATIONS
Siding(Hardboard and Cement)
Sheathing
Fencing
Subflooring
Roof decking
Exterior deck
Exterior trim
Furring
Strapping
4. AIR SUPPLY AND CONNEC-
TIONS
Read section titled "SAFETY INSTRUCTIONS"
DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COM-
PRESSOR
The tool is designed to operate on compressed air. Do not oper-
ate the tool on any other highpressure gas, combustible gases
(e.g., oxygen, acetylene, etc.) since there is the danger of an ex-
plosion. For this reason, absolutely do not use anything other
than an air compressor to operate the tool.
OPERATE WITHIN THE PROPER AIR PRESSURE RANGE
The tool designed to operate within an air pressure range of 70
to 100 p.s.i.. (5 to 7 bar)
The pressure should be adjusted to the type of the work being
fastened. The tool shall never be operated when the operating
pressure exceeds 120 p.s.i.. (8 bar)
DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUB-
STANCE
Never operate the tool near a flammable substance (e.g., thinner,
gasoline, etc.). Volatile fumes from these substances could be
drawn into the compressor and compressed together with the air
and this could result in an explosion.
1 Frame
2 Cylinder Cap
3 Contact Arm
4 Nose
5 Magazine
6 Trigger
7 Grip
8 Exhaust Port
9 Trigger Lock Dial
0 Adjustment Dial
a Hook
HEIGHT 11-7/8" (302 mm)
WIDTH 5" (127 mm)
LENGTH 10-7/8" (275 mm)
WEIGHT 5.2 lbs.(2.4 kg)
RECOMMENDED
OPERATING PRESSURE
70 to 100 p.s.i.
(5 to 7 bar)
LOADING CAPACITY 400 Nails
AIR CONSUMPTION
0.05 ft
3
at 100 p.s.i. (1.55 at 7 bar)
operating pressure
Collation type 15 degree flat wire
welded coil nails
15 degree flat plastic
collated coil nails
Shank type Smooth Screw Ring Smooth Screw Ring
Nail length 1-1/2" to 2-1/2"
(38 mm to 65 mm)
1-1/4" to 2-1/2"
(32 mm to 65 mm)
Shank diame-
ter
.083" to .099"
(2.1 mm to 2.5 mm)
.083" to .099"
(2.1 mm to 2.5 mm)
Head diameter .197" to .236"
(5.0 mm to 6.0 mm)
.197" to .236"
(5.0 mm to 6.0 mm)
5
9
6
2
7
4
1
3
8
10
11
WARNING
Thinner