Integrator's Manual

94
In addition to clicking the Syslog hyperlink at the top of any COM1000 web interface page, the
syslog data may also be accessed directly from the PairingInfo screen as discussed in Section 6.5
by clicking directly on the hyperlinks for each card‟s IP address, as seen in Figure 29.
It should be noted, however, that this particular feature will only give the results shown above if
the card you are logged into and the card you wish to access are both running a firmware version
higher than ST02.00.03. If a target card is not carrying the correct firmware, you will be
redirected to that card‟s Help page.
6.12 Using the COM24 ATSC Command
The ATSC command can control Technicolor ATSC tuner boards. There are eight tuners in each
board that can receive an ATSC channel and forward the transport stream to a QAM24. There is
a different IP address per every two tuners. This results in four different IP addresses per board.
First, the four IP addresses must be set. Specify the desired base IP address (such as
192.168.4.1) and click IP_Discover_and_Set. This will discover all of the ATSC tuners and set
their IP addresses starting with the base IP address.
Next, enter one line per tuner using this format:
HomeRun_IP Tuner_Index RF_Index Major.Minor Dest_IP Dest_Port
For example, to tune to WFYI 20-1, 20-2, and 20-3 with
ATSC Base IP address = 192.168.4.1
The Tuner_Index is either 0 or 1 for each IP address.
WFYI is carried on ATSC frequency 21.
QAM24 address is 192.168.6.2
Therefore enter the following three lines:
192.168.4.1 0 21 20.1 192.168.6.2 17
192.168.4.1 1 21 20.2 192.168.6.2 18
192.168.4.2 0 21 20.3 192.168.6.2 19