Integrator's Manual

56
Software Upgrade The fields in this section are covered on the next page.
Figure 30 below shows in detail the upgrade section available on the PairingInfo page.
Figure 30 COM24 Multi-card Upgrade Feature
Following is a brief description of the relevant fields on this page.
Upgrade By checking this box for a particular card, you will make each of the fields under
“Software Upgrade” heading active for that card. This method is more efficient in that it allows
you to update multiple cards to the latest software in one easy step.
Usage This field allows you to select which type of file transfer you wish to undertake for a
particular card. The available options are shown below. It should be noted that when selecting
any option other than „2‟, the card will appear to go through the usual software update cycle, but
that it will revert to the current build of code once it has rebooted.
0 = Set_Log_IP This option allows you to identify the IP address to which you wish to
send COM24 logging for monitoring by a syslog utility.
1 = NA This option is not available to new users and only exists in order to support
backward-compatibility with older builds of code.
2 = SW_Upgrade This is the only user-accessible means of updating the software in a
COM24 card.
3 = Log This option allows you to copy a COM24 card‟s internal log files to a PC.