Integrator's Manual

55
Following is a detailed list of information available on the PairingInfo page.
Chassis This field reports a unique identifier for the chassis. In systems that contain multiple
chassis, this can be used to identify each card in the system. See Section 4.1 on how to assign
unique identifiers to multiple chassis within a system.
Slot This field identifies the card‟s location within a chassis, numbered 1 through 12.
CardIP This field shows the IP address of the COM24 card that resides in the chassis and slot
combination to its left. This field is also a link to see the Syslog for that card.
RID This field reports the DIRECTV Receiver ID, or RID. This value is the first of two
parameters required to obtain authorization on the DIRECTV network.
CAM_ID This field reports the DIRECTV CAM ID. This value is the second parameter
required to obtain authorization on the DIRECTV network. For any card running a software
version above ST02.00.09, you can click on the hyperlink in this column to be taken directly to
that card‟s CAM Log (see Section 6.8.7 for more information on reading a card‟s CAM log).
Authorized This field reports whether the COM24 card‟s CAM has been authorized. A value
of „1‟ indicates that the card has been authorized, thereby enabling the card to receive DIRECTV
programming. A value of „0‟ indicates that the card has not been authorized.
Paired This field reports the pairing status of the CAM card. In order to be capable of
receiving an authorization to the DIRECTV network, the RID and CAM data must first be
paired. If this has not happened, then the card cannot be authorized until the pairing is resolved.
A value of „1‟ indicates that the RID and CAM are successfully paired; a value of „0‟ indicates
that they are not.
Note: Refer to Section 10.4 for more information if you notice a
card that has a value of „1‟ under both the “Authorized” and
“Paired” columns but is not streaming video properly.
SW_Version This field reports the software version that currently resides on the COM24 card.
All cards that have a similar web interface to the one described in this document will have a
version number of at least ST01.00.25. The examples given have been taken from cards that are
running the ST02.05.11 software release.
Up_Time This field gives an indication of how much time has elapsed since the card was last
rebooted or powered up.
Upgrade By checking this box for a particular card, you will make each of the fields at the
bottom of the screen active for that card. This allows you to upgrade multiple cards at a time.