User Manual

267
Appendices
Troubleshooting
Power supply
Power does not turn on
Is the power cable connected to an outlet? For more
information, see “Connections” on page 21.
Is the POWER switch turned on?
Turn on the rear panel POWER switch. See “Turning the
power on/off” on page 20.
Power turns off automatically
Is the Auto power-off function enabled? For more
information, see “Auto Power-Off” on page 20.
If the KRONOS is not cooled adequately, the internal
temperature will rise. The power supply may shut down
automatically to protect the device from high temperatures.
Startup does not complete
In some cases, the KRONOS will not start up properly if
certain USB storage devices are connected. In this case,
disconnect the USB devices from the KRONOS, wait about
10 seconds, and then turn on the power again. You may be
able to solve the problem by formatting the USB device on
the KRONOS (see “Formatting media” on page 206).
LCD screen
Display is blank or incorrect
The power is turned on, but nothing is shown in
the LCD screen. However, the KRONOS functions
normally when you play the keyboard or perform
other operations.
Is the LCD screen’s backlight brightness adjusted correctly?
1. Press the GLOBAL button.
2. Check that the GLOBAL button’s LED is lit.
If it is not lit:
2a.If the Sequencer START/STOP button’s LED is
flashing, press the button so that the LED turns off.
2b.Similarly, if the Sampling START/STOP button’s
LED is lit, press the button so that the LED turns off.
2c.Press the EXIT button several times to cancel any
other operations.
2d.Finally, press the GLOBAL button again.
Once the GLOBAL buttons’s LED is lit:
3. Press the EXIT switch twice.
4. Hold down the ENTER switch, and press numeric key
6.
The LCD Setup dialog will appear.
5. Use the VALUE slider or VALUE dial to increase the
brightness to an appropriate level.
You can also press the RESET CONTROLS button to reset
this to the standard value of 63.
6. Press the OK button to confirm the change.
The power is turned on, but the LCD screen does
not display normally, or an error message is
displayed. There is no sound when you play the
keyboard, and the KRONOS does not function
normally.
It is possible that the system has been damaged. Use the
included Accessory Disks to restore the KRONOS to its
factory state.
HD-1 Program P0: Play page display
The HD-1’s Program P0: Play page can display either photos
or other images representing the sound, or the
Overview/Jump graphics which show the settings of various
important parameters (such as EGs, LFOs, and so on).
The choice of which to display is controlled by a
combination of the Program P1:Program Basic page’s Play
Page MS/WS/DKit Display parameters (one for each
Oscillator) and the Program P0:Play page’s Show
MS/WS/DKit Graphics menu command. You can set these
as desired.
For more information, see “1–1h: Play Page MS/WS/DKit
Display” on page 46 of the Parameter Guide and “Show
MS/WS/DKit Graphics,” on page 154 of the Parameter
Guide.
Problems using the touch-screen
Cant operate the LCD screen correctly
On the Basic Setup tab of the Global P0 page, use the Touch
Panel Calibration page menu command to adjust the touch
panel response.
Note: If you are unable to select commands from the page
menu, do the following:
1. Press the GLOBAL switch.
2. Press the EXIT switch twice.
3. Hold down the ENTER switch and press 3 on the
numeric keypad.