SPM adapter for EMC® Symmetrix® VMAX®: Matrix support for automation of EMC storage operations via the HP Storage Provisioning Manager
Technical white paper
SPM adapter for EMC®
Symmetrix® VMAX®
Matrix support for automation of EMC storage operations via the
HP Storage Provisioning Manager
Table of contents
Introduction .................................................................................................................................................................................... 2
Requirements ................................................................................................................................................................................. 2
Hardware Requirements ......................................................................................................................................................... 2
Software Requirements .......................................................................................................................................................... 2
Installation ...................................................................................................................................................................................... 4
Enabling and Disabling the EMC adapter ............................................................................................................................. 4
Uninstall........................................................................................................................................................................................... 5
Upgrade ........................................................................................................................................................................................... 6
Configuration .................................................................................................................................................................................. 6
Setting EMC SMI-S Credentials ............................................................................................................................................... 6
Setting HTTP Timeout .............................................................................................................................................................. 6
Setting EMC Director Ports ...................................................................................................................................................... 6
Setting Flags on EMC Director Ports ..................................................................................................................................... 7
Using Suitable EMC Ports for Provisioning .......................................................................................................................... 8
Pre-Provisioning of Volumes and Thin Pools on EMC Symmetrix VMAX ...................................................................... 8
Importing an EMC Symmetrix VMAX storage array into SPM .............................................................................................. 9
Troubleshooting .......................................................................................................................................................................... 12
Unable to connect to the remote server ............................................................................................................................ 12
The remote server returned an error: (401) Unauthorized ........................................................................................... 13
The operation has timed out ................................................................................................................................................ 13
Failed to refresh resources from adapter 'EMCSymmVMax' ......................................................................................... 13
Storage pool setting does not exist for the given RAID.................................................................................................. 13
Growing thin volume feature is not supported ................................................................................................................ 13
Specified target ports cannot be used for presentation ................................................................................................ 15
The operation will result in consistent LUN violation ...................................................................................................... 15
The LUN value is invalid because VSA is enabled............................................................................................................. 16
Summary ....................................................................................................................................................................................... 17
For more information ................................................................................................................................................................. 17
Glossary ......................................................................................................................................................................................... 17