SPM adapter for EMC® Symmetrix® VMAX®: Matrix support for automation of EMC storage operations via the HP Storage Provisioning Manager

Technical white paper | SPM Adapter for EMC Symmetrix VMAX
4
Installation
When the Matrix Operating Environment is installed from the Insight Management DVD, the HP SPM adapter for EMC
Symmetrix VMAX will be installed under the SPM install path (C:\Program Files (x86)\HP\Storage
Provisioning Manager\EMCSymmVMAX). The administrator doing the installation has the option to exclude the
installation of the adapter (for example, if the environment does not contain EMC storage). If the adapter has not been
installed initially, it can be installed from the DVD at a later time.
Enabling and Disabling the EMC adapter
The SPM adapter for EMC Symmetrix VMAX storage array will be disabled when it is installed. When the adapter is disabled,
SPM doesn’t allow the administrator to perform import operations on the EMC Symmetrix VMAX arrays. Without the EMC
Adapter enabled, any EMC management must be done via the unmanaged array path (manual editing of SPM XML files).
Enabling the adapter will allow user to import the EMC Symmetrix VMAX arrays into the SPM catalog. This will automatically
include property information regarding the arrays, including storage pools and volumes which can be chosen for import.
The following subsections provide details for enabling and disabling the adapter.
Note
SPM operations result from the manual or automated creation of a storage pool entry for fulfillment through SPM or
provisioning a logical server (directly or from a Matrix infrastructure orchestration service template) which uses SPM
storage. Enabling or disabling the adapter will result in a stop and restart of the SPM service. This may affect ongoing SPM
operations. It is recommended to enable or disable the adapter when no SPM jobs are running.
Enabling the adapter
To enable the adapter perform the following steps:
Change directory to the adapter install path (C:\Program Files (x86)\HP\Storage Provisioning
Manager\EMCSymmVMAX).
Execute the batch script adapterController.bat as below:
AdapterController.bat enable
The AdapterController.bat file will also ensure restart of the SPM service. When the SPM service starts it detects the new
adapter and allows the administrator to select it within the Import Array Wizard and thus import EMC Symmetrix VMAX
arrays. It will be necessary to configure the EMC array credentials.
The EMC adapter will be detected by SPM when the SPM service is restarted (by the batch script above).
Disabling the adapter
Before disabling the adapter, it is advised to perform following steps as applicable:
Deactivate SPM services that are bound to resources on the EMC storage.
Remove the EMC Symmetrix VMAX array from the SPM catalog if it is imported. This will avoid any errors in SPM during its
periodic RefreshResources operations on the imported array objects.
Note
When an array is removed from SPM catalog, SPM will remove all imported pools and volumes from that array.
The adapter can be disabled by running the AdapterController.bat file located at the adapter install path, as below:
Change directory to adapter install path (C:\Program Files (x86)\HP\Storage Provisioning
Manager\EMCSymmVMAX)
Execute AdapterController.bat as below:
AdapterController.bat disable
While disabling, the AdapterController.bat file will stop and restart the SPM service.