Technical data
39
Cooling down (not DW20.1)
Machines with softener : Cool down step is NOT performed during regeneration.
Drain pump 5 sec
Inlet valve 24 sec
Circulation pump 60 sec
Drain pump 25 sec
Pre-rinse
Inlet valve 170 pulse* , 14 sec, 0.9 lit EU
Circulation pump 20 sec, Lower arm low pressure**
Drain pump 25 sec
1st. Rinse
Inlet valve 605 pulse*, 47 sec, 3.1 lit***
545 pulse* 43 sec, 2.8 lit EU**
Circulation pump 4 min
Circulation pump 60 sec, Upper arm high pressure**
Drain pump 2 sec SCS stage
Circulation pump 20 sec SCS stage Upper arm high pressure**
Drain pump 25 sec
Drain pump Inlet valve 100 pulse, 8 sec, 0,5 lit
Drain pump 8 sec
Final rinse
Inlet valve 605 pulse*, 47 sec, 3.1 lit***
545 pulse* 43 sec, 2.8 lit EU**
Circulation pump 60 sec
Circulation pump, Heater 65°C (70ºC in machines without drying selection)
Temperature stop
Circulation pump 3 sec
Circulation pump, Combined dispenser 60 sec
Circulation pump 4 min
Circulation pump 50 sec Upper arm high pressure**
Pause 60 sec
Drain pump 25 sec
Drying Fan 30 min