Owner manual

GOES RR Column 2 Source = Date rs
Response from XL™.
Command: GOESRRCOLUMNnSOURCE=XXXXXX
Description: Set the source of the n
th
data column of the RR GOES transmission.
Parameters: ‘n’ ranges from 1-5. The XL expects the new source of the data column
corresponding to ‘n’ (e.g. Stage, PSI, Temp).
Response: None.
Example:
-> GOESRRCOLUMN1SOURCE=Time5
Command sent to the XL.
rs
Response from the XL™.
C.12 Miscellaneous Commands
Command: OFF
Description: Turn the XL™ off. This command is also automatically executed if there has been
no user interaction for the last two minutes.
Parameters: None:
Response: The text string ‘Off’ will be sent back to the host. This is useful when the unit
times out and turns off automatically.
Example:
-> OFF5
Command sent to the XL.
OFFrs
The unit powers down to a low power mode.
Command: ECHOOFF
Description: Turn off the echoing of the commands. This is most useful if a user develops there
own interface to the logger. Not having to work with the echoing command makes
the design of the custom interface much simpler. To turn the echo back on use the
OFF command and then turn the logger back on.
Parameters: None.
C-44 Remote Operation (Command Mode)
H-5223