User Manual
23
CASSETTE CLOSE / CASH REPLENISHMENT
VERIFY OPERATION
1. After completion of the “CASSETTE CLOSE” procedures, close and lock the security cabinet.
2. Verify the cassettes are I
N SERVICE, (TDM-250).
3. In Management Functions, select DIAGNOSTICS > DISPENSER.
4. Select the TEST DISPENSE option. Select either individual cassettes that are installed: “A” or “B” or
“All Cassettes”. A prompt appears asking how many notes to dispense. The Test Dispense operation
will start.
5. The Test Dispense command instructs the dispenser to dispense, minimum, one note from each
installed and operational cassette into the reject vault. This test exercises the dispenser without
sending notes to the exit.
6. After completion of the Test Dispense, the following prompt is displayed. “Test Dispense Completed
Successfully - Dispense Count , A: (# of notes), B: #, etc.
Enter # of notes.
If you use the REAR SERVICE PANEL:
1. After completion of the “CASSETTE CLOSE” procedures, close and lock the security cabinet.
2. Verify the cassettes are IN SERVICE, (TDM-250).
3. In the MAIN MENU screen, press DIAGNOSTICS, then DISPENSER. Select the TEST DISPENSE option.
Select either individual cassettes that are installed: “A” or “B” or “All Cassettes”. A prompt appears
asking how many notes to dispense. The Test Dispense operation will start.
4. After completion of the Test Dispense, a prompt is displayed - “Test Dispense Completed Successfully
- Dispense Count , A: (# of notes), B: #.