Technical data

8.4 Extension Cards
8.4.1 General Information
PCIe slots and PCI slots are available for plugging extension cards. The max‐
imum performance for all extension cards for the devices provided with a
Celeron 440 processor is a total of 100 watt. The maximum performance for all
extension cards with an Intel
®
Core2
TM
processor is 70 watt.
WARNING
Risk of damage to the control cabinet PC or to the extension cards due
to electrostatic discharges!
Comply with all ESD protective measures while working with modules and
components! Avoid electrostatic discharges!
WARNING
Risk of damage to the control cabinet PC or corruption of application
software due to the use of of non-released extension cards!
Only released extension cards are to be installed. Installation is only to be car‐
ried out by authorized personnel.
8.4.2 Inserting Extension Card
1. All required user data as well as the operating system settings of the sys‐
tem are to be stored either on an external storage medium or via the
network connection! See also chapter 9 "Software" on page 55.
2. Switch off the supply voltage.
3. Wait until the power supply unit switches off automatically after the UPS
operation.
4. Ensure that no voltage is in the control cabinet PC. Disconnect the PC
voltage supply from the X10 connection, if required, see "24 VDC voltage
supply" on page 38.
5. Remove the five marked screws at the housing side, see fig. 8-2 "Loosen
the fastening screws at the mounting frame" on page 49.
Project Planning Manual | Rexroth IndraControl VSB 40.3 Electric Drives
and Controls
| Bosch Rexroth AG 51/101
Maintenance and Installation