User guide

8-6
FlexPak 3000 DC Drive Software Reference
FIELD
DELTA
(P.588)
The field firing angle
in degrees.
Parameter Range:
0 to 180
DEGREE
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Field - Field Current Regulator - Field Loop Test
Points
FIELD
FEEDBACK
(P.589)
Motor field current
feedback signal after
scaling and gain.
Parameter Range:
+/-
MOTOR
HOT
FLD
AMPS
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Field - Field Current Regulator - Field Loop Feedback
Scaling
Field - Field Current Regulator - Field Loop Test
Points
FIELD
PI
LEAD
FREQ
(P.515)
Lead frequency for
the field current
PI
block.
Parameter Range:
0 to 282.70
RAD
/
S
Default Setting:
1.50 rad/s
Parameter Type:
Tun abl e
OIM Menu Path(s):
Field - Field Current Regulator - Field Loop Tuning
FIELD
PI
PROP
GAIN
(P.514)
Proportional gain
setting for the field
current
PI
block.
Parameter Range:
0.10 to 128.00
Default Setting:
0.50
Parameter Type:
Tun abl e
OIM Menu Path(s):
Field - Field Current Regulator - Field Loop Tuning