Instruction Manual
86
E SR-750 UM
Configuring the KV Series
RS-232C Interface
*1 To use port2, set the interface to "RS-232C".
*2 For KV BUILDER/KV STUDIO mode, a fixed value is used.
Ethernet Interface
MELSEC Series Configuration
RS-232C Interface
QJ71C24N/-R2
Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")
("Option configuration" under "I/O assignment settings" in "PC parameters")
("Switch configuration" under "I/O assignment configuration" in "PC parameters")
Operation KV BUILDER/KV STUDIO mode
Interface RS-232C
*1
Division 0
Baud rate Automatic
*2
Data bit length 8 bits
*2
Parity Even (e)
*2
Stop bit length 1 bit
*2
Checksum None
*2
RS/CSFlow control Disable
IP address 192.168.0.10 (default)
Subnet mask 255.255.255.0 (default)
Port (VT) 8502 (default)
Type Intelligent
Type name Name of the unit to be installed
Points 32 points
First XY First output signal of the target unit (hexadecimal number)
Unit type Serial communication/modem interface unit
Unit type name Name of the unit to be installed
Setting item Value
Operation configuration Independent
Data bit length 8 bits
Parity bit Present
Odd/even parity Odd (o)
Stop bit length 1 bit
Checksum code Present
Writing during RUN Allowed
Configuration change Allowed
Communication rate
configuration
9600 bps
Communication protocol
configuration
MC protocol (format 5)
Division configuration 0
Ethernet Interface
QJ71E71-100/-B5/-B2
Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")
(Target unit number for "Ethernet/CC IE/MELSECNET" in "Network parameters")
("Operation configuration" for "Ethernet/CC IE/MELSECNET" in "Network
parameters")
*1 Configure so that it matches the network.
* The port number is 5000.
Q03/04/06/10/13/20/26/50/100UDECPU
Set communication conditions with the GX-Developer.
("Built-in Ethernet port configuration" in "PC parameters")
*1 Configure so that it matches the network.
("Built-in Ethernet port configuration" in "PC parameters")
* The port number of the SR-750 Series must be specified in decimal number while
the Q Series port number with Ethernet module installed is specified in
hexadecimal number.
L02CPU/26CPU-BT
Set communication conditions with the GX-Works2.
("Built-in Ethernet port configuration" in "PC parameters")
*1 Make the configuration appropriate to the network.
("Built-in Ethernet port configuration" in "PC parameters")
* The port number of the SR-750 Series must be set in decimal numbers.
Type Intelligent
Type name Name of the unit to be installed
Points 32 points
First XY First output signal of the target unit (hexadecimal number)
Network type Ethernet
First I/O No.
Number specified in "I/O assignment configuration" in PC
parameters
Network No. Any number
Group No. Any number
Division Any number
Mode Online
Communication data code
configuration
Binary code communication
Initial timing configuration Always waiting for OPEN (Communication possible during STOP)
IP address 192.168.0.20
*1
Writing permitted during
RUN
Check
Send frame configuration Ethernet (V2.0)
TCP living confirmation
configuration
KeepAlive is used.
IP address 192.168.0.20 *1
Subnet mask patterns 255.255.255.0
*1
Default router IP address 192.168.0.254
*1
Communication data code
configuration
Binary code communication
Writing permitted during
RUN
(FTP and MC protocol)
Check
Protocol UDP
Open system MC protocol
Port number with Ethernet
module installed
232C (hexadecimal number) * Any number
Example)
Hexadecimal number Decimal number
232C 9004
IP address 192.168.0.20
*1
Subnet mask patterns 255.255.255.0
*1
Default router IP address 192.168.0.254
*1
Communication data code
configuration
Binary code communication
Writing permitted during
RUN
(FTP and MC protocol)
Check
Protocol UDP
Open system MC protocol
Port number with Ethernet
module installed
232C (hexadecimal number) * Any number