Instruction Manual
82
E SR-750 UM
Data port 2 settings
Function
Command
Number
Setting
value
Explanation Default
Remote IP address
(TCP communication)
300 a.b.c.d
a:0 to 255
b:0 to 255
c:0 to 255
d:0 to 255
Use when the protocol is TCP.
0.0.0.0
(Not set)
Remote port
(TCP communication)
301
1024 to
65535
Use only for TPC protocol. 5000
Protocol setting 303 0 to 5
0 : MC protocol
1 : SYSWAY
*1
2 : KV STUDIO
3:None
or TCP
*2
4 : EtherNet/IP
5:PROFINET
0
DM front address 304
MC:
0 to 32767
SYSWAY:
0 to 9999
KV:
0 to 65534
0
Control region address 305
MC:
0 to 7F
SYSWAY:
0 to 6143
KV:
1 to 599
0
Response region
address
306
MC:
0 to 7F
SYSWAY:
0 to 6143
KV:
1 to 599
0
Output data length
setting
307
001 to
100
* Set the upper limit of writing
length.
64
PLC link timing input 308 0, 1
0 : Disable
1:Enable
0
Timing/Data wait 309 00 to 99 by the 100 ms 1
Retry duration (s) 310 01 to 30 by the second 5
EtherNet/IP
data handshake setting
321 0, 1
0 : Do not handshake
1 : Handshake
0
EtherNet/IP
Input assembly data
size setting
322
0040 to
1400
by 1 500
EtherNet/IP
Output assembly data
size setting
323
0040 to
1400
by 1 500
EtherNet/IP
Byte swapping setting
324 0, 1
0 : Disable (ROCKWELL)
1 : Enable (KEYENCE/OMRON)
0
PROFINET device
name
330 nnn…
Up to 240 characters
Specify with ASCII codes
* Device naming rule
1 : PROFINET device name
length: 1 to 240 characters
2 : 1 label length: 1 to 63
characters
3 : Only [a to z] (alphabet lower
case), [0 to 9] (numbers), [-]
(hyphen), [.] (period) can be
used for a device name.
4 : [-] (hyphen) cannot be used at
the beginning of the label.
5 : [-] (hyphen) cannot be used at
the end of the label.
6 : port-xyz, port-xyz-abcde
cannot be the name of the
first label.
abcde and xyz mean [0 to 9]
(numbers).
7 : Device names cannot be
made in the IP address
format.
(n.n.n.n n=0.….999)
8 : Labels cannot start with xn-.
9 : The first character of labels
cannot be a number.
If these rules are not observed, an
error occurs.
sr-750
PROFINET handshake 331 0, 1
0 : Do not handshake
1 : Handshake
0
*1: When Data port 2
is set to Ethernet,
1 cannot be used.
*2: Depends on the
Data port 2
configuration.
FTP Communication Settings
Master/Slave function settings
Function
Command
Number
Setting
value
Explanation Default
IP address of the
connection destination
FTP server
400 a.b.c.d
a : 0 to 255
b : 0 to 255
c : 0 to 255
d : 0 to 255
For 0.0.0.0., the FTP client does
not operate.
0.0.0.0
(Not set)
User name of the
connection destination
FTP server
401 aaaa··· ASCII setting (max. 16 characters) admin
Password of the
connection destination
FTP server
402 aaaa··· ASCII setting (max. 16 characters) admin
Directory transfer at
connection
403 0, 1
0 : Disable
1:Enable
0
Directly name of the
transfer destination
404 aaaa··· ASCII setting (max. 32 characters) image
FTP connection request
transmission as
necessary
405 0, 1
0 : Disable
1:Enable
0
NOOP command
transmission
406 0, 1
0 : Disable
1:Enable
1
NOOP command
transmission interval
407 01 to 10 units: minute 1
PASV command
transmission
408 0, 1
0 : Disable
1:Enable
0
Format setting for FTP
transmission
411 0, 1
0:Bitmap
1:JPEG
1
JPEG quality for FTP
transmission
412 01 to 10 05
Binning setting for FTP
transmission
413 0 to 3
0 : No binning
1 : 1/4 skipping
2 : 1/16 skipping
3 : 1/64 skipping
1
Function
Command
Number
Setting
value
Explanation Default
Master/Slave operation
configuration
500 0 to 2
0 : Disable
1 : Multi drop link
2 : Multi head
0
Master/Slave ID during
operation
501 0 to 31 If 0 is set, it operates as Master. 0
Number of read data in
Multi Head mode
502 1 to 8 1
Master/Slave function
group name
503 nnnn…
Up to 16 characters
Specify with ASCII codes
* 0x20 to 0x7E of ASCII codes can
be used.
GROUP01