Veritas Storage Foundation 5.1 SP1 Cluster File System Administrator"s Guide (5900-1738, April 2011)
9
Review the message that the utility displays and confirm that you want to
commit the new set of coordinator disks. Else skip to step 10.
Do you wish to commit this change? [y/n] (default: n) y
If the utility successfully commits, the utility moves the /etc/vxfentab.test
file to the /etc/vxfentab file.
10
If you do not want to commit the new set of coordinator disks, answer n.
The vxfenswap utility rolls back the disk replacement operation.
Replacing the coordinator diskgroup in a cluster that is online
You can also replace the coordinator diskgroup using the vxfenswap utility. The
following example replaces the coordinator disk group vxfencoorddg with a new
disk group vxfendg.
To replace the coordinator diskgroup
1
Make sure system-to-system communication is functioning properly.
2
Make sure that the cluster is online.
# vxfenadm -d
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: 201
Fencing Mode: SCSI3
Fencing SCSI3 Disk Policy: dmp
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
3
Find the name of the current coordinator diskgroup (typically vxfencoorddg)
that is in the /etc/vxfendg file.
# cat /etc/vxfendg
vxfencoorddg
Administering Storage Foundation Cluster File System and its components
Administering I/O Fencing
90