Operation Manual
548 Organization mode of operation
8.2 Parameters
Settings for the simulation:
Parameters: Simulation / ... Meaning
... / General settings (114800) / ...
... / Restart with M99 (114801)
ON Simulation begins again at beginning of program
OFF Simulation stops
... / Traverse delay [s] (114802) Delay time after each path has been graphically
simulated. The simulation speed can thus be
influenced.
... / Software limit switches active (114803)
ON Software limit switches also active during simulation
OFF Software limit switches not active during simulation
... / Machining times for the NC functions in general (115000) / ... These times are used as nonmachining times for the
time calculation function.
... / Time allowance for tool change [s] (115001)
... / Time allowance for gear shifting [s] (115002)
... / General time allowance for M functions [s] (115003)
... / Machining times for M functions (115100) / ... Individual time allowances for a maximum of 20 M
functions
... / T01 / ...
... / Number of the M function
... / Operating time of the M function [s] The time calculation adds this time to the "General
time allowance for M functions."
... / T20
... / Specification of the (standard) window size (115200) The simulation function adapts the window size to the
workpiece blank. If no blank part is programmed, the
simulation uses a standard window size.
... / Zero point position in X [mm] (115201) Distance of the coordinate origin from the lower
window edge.
... / Zero point position in Z [mm] (115202) Distance of the coordinate origin from the left edge of
the window.
... / Delta X [mm] (115203) Vertical expansion of the graphic window
... / Delta Z [mm] (115204) Horizontal expansion of the graphic window
... / Specification of the (standard) workpiece blank size (115300) If no blank part is programmed in DIN PLUS, the
simulation uses a "standard blank."