■Contents・・・・・・・・・・・・・・・・・1 ■Parts List・・・・・・・・・・・・・・・・2 ■Safety Notice・・・・・・・・・・・・・3~4 ■Before you install・・・・・・・・・・・・5 ■Installation Method ・・・・・・・・・6~9 ■Operation Method・・・・・・・・・10~15 ■Before you think breakdown・・・・・・・16 ■Contact ・・・・・・・・・・・・・・・・17 1
Parts List ※ w/ Aluminum Plate Controller Display φ6 Hose 1m 1 1 φ4 Nylon Tube 2m 1 Main Harness 1 Double Sided Tape 1 1 T Pipe Joint 1 φ4 Hose Joint 1 2 Installation Manual 1 Wire Tie 5 1 Conversion Harness 1 Solenoid Valve for Type S 1 Solenoid Fixed Parts 1 φ6 Crescent Clamp 4 CPU Unit Splice カスタマー登録方法 ココから切り取ってお送りください。 保 証 規 定 1年間保証 年間保証 □連絡先 □住 所 □T E L 株式会社ブリッツ サポートセンター 東京都西東京市新町4-7-6 東京都西東京市新町 4-7-6 0422-60-2277 Warrenty Sheet 1 ■ TYPE R Only Solenoid Valve for
- Safety Notice - In order to use the product safely, please read the " SEFETY NOTICE" thoroughly. Explanation of warning symbols Ignoring these indications may cause serious injuries or even death to the individual and (or) to a third party. 警告 Ignoring these indications may cause serious injuries or injuries to the individual and (or) to a third party. 注意 Ignoring these indications may cause injuries or minor injuries to the indicidual and (or) to a third party.
- Safety Notice - 注意 Ignoring these indications may cause injuries or minor injuries to the individual and to a third party. It may cause malfunctions and breakages to the product. ・Ask for a professional or technician to perform the installation of this product. The individual performing this installation must have technical skills and knowledge to perform this installation. ・Do NOT drop or insert extreme force to the product while installing. It would cause malfunctions.
- Before you install - ■Controller Display Select Switch UP/DOWN Switch ■CPU Unit Do not apply strong force or bending and pulling on nylon hose from the base position. It may cause damage. Connect into Controller Display Connect into Main Harness Peel off the double sided tape from alminum plate and put to the CPU Unit.
- Installation Method ① - ※This product is designed to work on 12V DC and DO NOT install on 24V DC. It may cause a fire by an electric short, breakage of electronic part and burn. ■Warning on installation 1.Remove the negative terminal of the battery. It will prevent the breakage and fire from parts by short-circuits. 2.Be careful not to make mistakes installing the hoses for the solenoid unit since it has an IN and OUT.
- Installation Method ② - ■Piping to Intake Manifold Intake Manifold Fuel Tube T pipe Joint Cut the hose Please secured by wire tie Fuel Pressur Regulator Nylon hose into the vehicle ■Piping to Valve Unit ●Solenoid Valve(TYPE S) Install the nipple follows by top plate. Actuator and Waste gate has a different installation method. Remove all the caps. Actuator Type Washer Rubber Washer Using by 1/8 taper thread cannot inseat very far.
- Installation Method ③ - ■Actuator Model(Swing Valve) <For Single Turbo> Turbo Charger IN port OUT port <For Twin Turbo> ※Needs to purchase as an optional (PN:14026) OUT port Take out factory fitting IN port 3 way joint ■Installtion of twin solenoid valve. 1.Do not install at highly heated or humid location inside the engine compartment.
- Installation Method ④ - ■Wastegate Type(Poppet Valve) 1.Take the boost pressure between the turbo charger's compressor cover and the throttle body are connected to the valve IN to make sure of using the clamps supplied from the kit. 2.Connect the valve OUT to the room A of the waste gate to make sure of using the clamps supplied from the kit. 3.The boost pressure must be connected from the compressor cover and room B of the waste gate to make sure of using the clamp supplied from the kit.
- Operation Method ① - ■Set for Boost Pressure 1.While display is flashing, use ▼▲ to adjust desired boost level, then press button to set. 2.Hold the button for 2 seconds while in“boost”mode. 3.When“SET”is flashing, use ▼▲ to adjust “DUTY”then press button to set. 4 Use ▼▲ to adjust“GAIN”then press to set. 5.Use ▼▲ to adjust“P-GAIN”then press button to set. If“P-GAIN”is set to“0”, then“P-GAIN”will be disabled. 6.When the“SET”turns off, the boost setting will be displayed.
- Operation Method ②- ■Peak Mode <After Peak> 1.Use ▼▲ to adjust THE peak when the display flashes, then press to set.”PK” will flash. 2.Boost will be displayed in real time. If maximum boost achieved is equal to or greater than the PEAK setting, This level will flash for 3 seconds. If maximum boost achieved is lower than the set level, the display will return to the PEAK setting. 3.Press the button to display boost.
- Operation Method ③- ■Set for Warning and Boost limiter 1.Use ▼▲ to choose warning when the display brinks, then press to decide. (SET shows and WR brinks) 2.Use ▼▲ to choose the boost pressure, then press Off~3.00hkPa(43.5PSI) to decide. WR ON … WR shows WR OFF … WR not shows 3.Use ▼▲ to choose boost limiter, then press (-99~100) 0 ……………… Limiter Off -99~-1 1~100 … When the set pressure of boost hits control of decreasing until the set pressure of DUTY.
- Operation Method ④ - ■Set for scramble 1.Use ▼▲ to select when“S”shows, then press button. 2.Use ▼▲ to select“DUTY”on the scramble time, then press button.(0~100) (SET on, S brinks and DUTY brinks) 3.Use ▼▲ to select“GAIN”on the scramble time, then press button.(0~100) (SET on, S brinks and GAIN brinks) 4.Use ▼▲ to select“P-GAIN”on the scramble time, then press button.(0~100) (SET on, S brinks and P-GAIN brinks) 5.
- Oparation Method ⑤ - ■Set for Remote Control Opt 15042 Wireless Remote Switch as optinal can be used to control some functions of the SBC. 1.Use ▼▲ to select“R”.“R”should flash, then press to set. 2.Use ▼▲ to select“CH”or“SC”. If CH is selected, the Optional Remote can select between LO or HI. If SC is selected, the Optional Remote can activate SCRAMBLE mode. 3. Press then boost level will be displayed. Connecting the Optional Wireless Remote Switch 1.
- Operation Method ⑥ - ■General Settings 1.Use ▼▲ to select SET then press when SET flashes. 2.While SET flashes, a bar graph will display brightness level. Use ▼▲ to select brightness level then press to set. 3.Use ▼▲ to select BEEP“ON”or“OFF” then press to set. 4.Use ▼▲ to select“hkPa”or“PSI”, then press to set. 5.Use ▼▲ to select“GT”ONLY when using SBC R (15039) with an external wastegate. Select "AC" when using acuator type. Select "AC" when using SBC S (15040) regardless if actuator or wastegate.
- Before you think breakdown - Case No POWER No control of boost No boost Always working warning Cause Answer Power line is not connected Wire is not connected Ground is not connected Connector is not connected Check on the tester Check the wire with the tester Make sure to get ground. Re-connect the connector AC/GT is wrong IN/OUT hose connects opposite Hose may broke or leaking the air Intake manifold is not connect correct. Check the setting. Check the hose on right place.
- Contact - ■Part Number and Product Name Part Number:15039 Part Number:15040 Product Name:SBC TYPE R Product Name:SBC TYPE S ■Inquiry about the product BLITZ Co., Ltd. 4-7-6 SHIN-MACHI, NISHITOKYO-CITY, TOKYO 202-0023 JAPAN TEL:+81-422-60-2277 FAX:+81-422-60-0066 URL:http://www.blitz.co.jp ■Sold by BLITZ Co., Ltd.