Handbook

Table Of Contents
800MHz BDA (Pasadena Figuero Tunnel)
Maintenance Handbook
H/book Number:-60-056100HBKM
Issue No:-1
Date:-21/10/2003
Page:-
52 of 52
APPENDIX A INITIAL EQUIPMENT SET-UP CALCULATIONS
GENERAL INFORMATION
Site Name: Client Name:
Date: AFL Equip. Model Nō.
ANTENNA SYSTEMS
Model Gain Azimuth Comments
A - Service Antenna
B – Donor Antenna
Type Loss Length Comments
C – Service Feeder
D – Donor Feeder
INITIAL PARAMETERS
E – CE Output Power
dBm
F – Antenna Isolation
dB
G – Input signal level from donor BTS
dBm
Operating Voltage V
DOWNLINK CALCULATIONS
Parameter Comments Value
Input signal level (G)
dBm
CE max. o/p power (E)
dBm
Gain setting
E - G
dB
Isolation required (Gain + 10dB) dB
Service antenna gain (A)
dB
Service antenna feeder loss (C)
dB
Effective radiated power (ERP)
E+A-C
dBm
Attenuator setting CE gain-gain setting dB
If the input signal level in the uplink path is known and steady, use the following calculation
table to determine the gain setting. If the CE features Automatic Gain Control the attenuator
should be set to zero and if not, then the attenuation setting for both uplink and downlink
should be similar.
UPLINK CALCULATIONS
Parameter Comments Value
Input signal level dBm
CE max. o/p power (E)
dBm
Gain setting dB
Required isolation dB
Donor antenna gain (B)
dB
Donor antenna feeder loss (D)
dB
Effective radiated power (ERP)
E+B-D
dBm
Attenuator setting (CE gain-gain setting) dB