5. PCB Manual Test Mode
- PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
: Press power button -> Press "SPIN" button 3 times with pressing "WASH" button -> "X X X" will be
shown on LED display-> Whenever pressing "Signal" button 1 time, below process will be occurred.
- "X X X' : Program version display
2) More details
- When turn on 'LOCK' signal, all process is conducting normaly.
- In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
Step Display Details
1 L_C Door Lock Close
2 run 001 Running times count
3E50 E5 Error count
4E60 E6 Error count
5E70 E7 Error count
6E80 E8 Error count
7F Do not use
8H Hot Valve on
9C Cold Valve on
10 P Pre Wash Valve on
11 d Do not use
12 b Bleach Valve
13 dr Drainage pump on
14 L_O Door Lock Open