Owner manual

--- GOES Main Menu —--
Time: HH:MM:SS
M - Mode: Off
A - Address: ABCD1234
S - Self Timed Options
R - Random Options
D - Diagnostics
Enter Option >
Time
This is the DCP time and is automatically set to international standard time by the GPS
system. The user cannot set or change the time manually. The data logger time clock is
separate from this time clock and is can be set to local time.
M - Mode
This allows the user to define the GOES Radio mode of operation. Options include Off, Self
Timed Transmissions Enabled, Random Transmissions Enabled, and both Self Timed and
Random transmissions enabled. This option should only be turned on after all other GOES
options are defined.
NOTE: The GOES mode cannot be turned on if the GOES clock has not been set by the
GPS system.
A - Address
This is the 8 character DCP ID assigned by NESDIS.
3.7.2.1. S - Self Timed Options
This screen shows the “Self Timed Transmissions” options:
--- Self Timed Options —--
C - Channel Number:
000
R - Transmit Rate:
HH:MM:SS
O - Tx Offset Time:
HH:MM:SS
W - Self Timed Window: 1
Min
S - Self Timed Baud Rate:
100
D - Data Format Options
T - Transmit Options
Enter Option >
H-5223 Remote Operation (Menu Mode) 3-17