INSTALLATION GUIDE & USER’S MANUAL ISLAND MOUNT RANGE HOOD Model: Pro-X Series PX06-I36 / I42 / I48 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL & INDOOR USE ONLY www.XtremeAirUsa.
TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS ......................................................................................................................... 2 2 HEIGHT & CLEARANCE ............................................................................................................................................ 3 3 VENTING REQUIREMENT ..........................................................................................................................................
2. HEIGHT & CLEARANCE 3. VENTING REQUIREMENTS IMPORTANT: NEVER exhaust air or terminate ductwork into crawl spaces, between walls, ceiling, attics or garages. All exhaust must be ducted to the outside. Hood mounted too low could result in heat and/or fire hazard. Hoods mounted too high will be hard to reach and will lose its performance and efficiency. Use metal ductwork only. DO NOT use plastic ventilation. DO NOT use 4” (10.2 cm) laundry-type wall caps.
8. GENERAL INSTALALTION DIAGRAM 7. PARTS SUPPLIED PART SKETCH DESCRIPTION P CEILNG MOUNT 1 BRACKET (W/18 ATTACHED BOLTS P (4) MULTI-HOLE 2 BRACKET (W/ 16 ATTACHED BOLTS) P (4) LOWER 3 CHIMNEY BRACKET (W/ 16 ATTACHED BOLTS) (4) 1 ¾” SCREWS P ALUMINUM PIPE 5 (2) DUCT CLAMP REMOTE CONTROL G U S C U H C UPPER “SLOT” CHIMNEY DIMENSION TABLE UPPER “HOOK” CHIMNEY L S C LOWER “SLOT” CHIMNEY L H C LOWER “HOOK” CHIMNEY D1 11.3 inch Ceiling mount bracket depth D2 3.
9. INSTALLATION STEP #2: INSTALLING “CEILING BRACKET” A. Cut out a hole in the ceiling where the ducting will go. B. Prepare support framework for ceiling bracket. C. Place chimney bracket against ceiling & screw it into place. D. Drop the ducting and electrical work through the ceiling. STEP #1: MARKING “CEILING BRACKET” A. Put a thick, protective covering over counter top, cook top or Range to protect from damage or debris. B. Find and mark the center point directly above your cook top. C.
10. OPEN & REMOVE BAFLE FILTERS 1 TO REMOVE: While a baffle filter is open, use both hand to hold both end of it then use your index finger (either left or right) to push baffle filter hinge pin toward to middle of baffle filter to release it. TO INSTALL: Please reverse the process. OPEN: While holding a baffle filter, pull baffle filter lock down. 11. RANGE HOOD OPERATION IMPORTANT: BEFORE YOU BEGIN 1. This unit is equipped with TOUCH SENSITIVE CONTROLS so please DO NOT PRESS.
C. Activating Power-Off Delay Function: 1. While the range hood is on and the blower is running in normal mode, touch Power-Off Delay button to activate delay off timer. 2. Adjust to desired period of delay of timer by touching (-) or (+) button quickly (1-15 minutes). Timer begins to countdown immediately, when it reaches 0, the blower will shut off. 3. Display screen will show flashing clock if timer is working. D.
3. The blower or fan seems weak: Check that the duct sized used is at least 6”. Range hood WILL NOT function efficiently with insufficient duct size & loosely secured. Check if duct is clogged or if damper unit (half-circular flapper) is not installed correctly or opening properly. A tight mesh on a side wall cap unit might also cause restriction to the air flow. 4. The lights work but the blower is not spinning at all, is stuck or is rattling.
15. LIMITED WARRANTY www.XtremeAirUsa.