Level Range
1. Place level on the oven bottom, as indicated in one of the two
figures below, depending on the size of the level. Check with
the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
®
Self-
Clean Technology.
Electrical Connection - U.S.A. Only
If your home has a 3- or 4-wire receptacle, continue with “Install
Using a Power Supply Cord.” If your home has a 3- or 4-wire
direct connection, go to “Install Using Direct Wire.”
Install Using a Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Power Supply Cord Strain Relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back of
the range. Pull the bottom of the cover toward you and out to
remove cover from range.
A. Mounting tabs (3)
B. Lower access cover
C. Screws (2)
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4. Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
Go to Section:
3-wire receptacle
(NEMA type 10-50R)
A UL listed, 250 V
minimum, 40 or 50
A, range power
supply cord
3-Wire Connection:
Power Supply
Cord
4-wire receptacle
(NEMA type 14-50R)
A UL listed, 250 V
minimum, 40 or 50
A, range power
supply cord
4-Wire Connection:
Power Supply
Cord