Installation Professional Built-in Hoods
Table of Contents Warnings & Important Information _________________________________________________________ 3 VWH 10”H.
IMPORTANT–Please Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first. WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 2.
IMPORTANT–Please Read and Follow! WARNING WARNING To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.) To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Dimensions & Specifications (VWH 10”H. Wall Hoods w/Standard Ventilator 30”, & 36”) 1 (30 2 ” .5 cm ) (7. 3” 6c m ) 1 (25 0 ” .4 cm ) A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) ” 21 cm) A .3 (53 NOTE: Optional duct cover sold separately. VWH 10”H. Wall Hoods w/Standard Ventilator Description 30” 36” 29-7/8” (75.9 cm) Duct cover width 35-7/8” (91.1 cm) Duct cover depth 12” (30.5 cm) Duct cover height 12” (30.
Clearance Dimensions (VWH 10”H. Wall Hoods w/Standard Ventilator) 60 24 (15 ”m 2.4 in. c 63 to m) ” (16 ma 0.0 x. cm ) (61”min .0 . c 27 to m) ”m (68 ax .6 .* cm ) ” 36 cm) .4 (91 * NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used.
Interior Ventilator Dimensions (VWH 10”H. Wall Hoods w/Standard Ventilator) Top View 30”W. 36”W. A 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) A 18” (4.6 cm) B 30”W. 36”W. B 8-1/4” (20.9 cm) 11-1/4” (28.6 cm) 30”W. 36”W. C 14-15/16” (37.9 cm) 17-15/16” (45.6 cm) 30”W. 36”W. D 3-5/8” (9.2 cm) 6-5/8” (16.8 cm) D 3-4” (1.9 cm) C 4” (10.2 cm) 3-7/8” (9.8 cm) 7” (17.8 cm) dia. duct location Interior Ventilator Installation 7 1/2” (1.3 cm) 3-1/2” (8.
Planning Information Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated. • Straight runs and gradual turns are best; for example, each 90º elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run. • Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) 2 1 Check damper for unrestricted movement, adjust if necessary. Attach transition to damper. Seal with aluminum tape. 3 WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
6 5/16” nut driver 5/16” nut driver CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary. 8 BARE OR GREEN 1 1 2 GREEN BLACK WHITE BLACK WHITE Connect black to black, white to white, and the green/bare wire under the green screw.
1 3 2 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator) 1 2 Measure distance from ceiling to canopy. Installation 2 Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. (VWH 10”H. Wall Hoods w/Recirculating Kit) 1 2 Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit.
3 4 Attach with screws and lock washers provided. Attach with screws. WARNING 5 To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
8 9 BARE OR GREEN 1 1 2 GREEN BLACK WHITE BLACK WHITE Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit. Replace electrical box cover. Make connection to breaker box. 10 11 1 2 3 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Assemble brackets to baffles and insert charcoal filters.
Service & Registration If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the problem that you are having.
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US or brigade.