FCC ID: AXI11154620 IC: 10239A-11154620 EVX-539 Operating Manual 1 2 3 A 4 5 6 B 7 8 9 C 0 # D EVX-539 Programmable Functions/Features IP57 Submersible (1 m/30 min.
FCC ID: AXI11154620 IC: 10239A-11154620 Contents Introduction...............................................................1 Warning! FCC RF Exposure Requirements...........2 Before You Begin.......................................................4 Battery Pack Installation and Removal................4 Battery Charging...................................................4 Low Battery Indication.........................................5 Belt Clip Installation and Removal......................
FCC ID: AXI11154620 IC: 10239A-11154620 Introduction The EVX-539 is full-featured Hand-Held Digital/Analog Transceiver designed for business communications in the VHF/UHF Land Mobile bands. This transceiver is designed for reliable business communications in a wide variety of applications with a wide range of operating capability provided by their leading-edge design. The EVX-539 allows to 512-channel capacity and 32 groups which can each be programmed with an 8-character Alpha-Numeric Tag.
FCC ID: AXI11154620 IC: 10239A-11154620 Warning! FCC RF Exposure Requirements This Radio has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for Occupational Use/Controlled exposure environment. In addition, it complies with the following Standards and Guidelines: FCC 96-326, Guidelines for Evaluating the Environmental Effects of Radio-Frequency Radiation.
FCC ID: AXI11154620 IC: 10239A-11154620 Warning! FCC RF Exposure Requirements When transmitting, hold the radio in a vertical position with its microphone 2 inches (5 cm) away from your mouth and keep the antenna at least 2 inches (5 cm) away from your head and body. The radio must be used with a maximum operating duty cycle not exceeding 50%, in typical Push-toTalk configurations. DO NOT transmit for more than 50% of total radio use time (50% duty cycle).
FCC ID: AXI11154620 IC: 10239A-11154620 Before You Begin Battery Pack Installation and Removal To install the battery pack, align the battery pack to the radio with an offset about 1/2 inch (1.5 cm) from the top edge of battery compartment, then slide the battery pack upward until it locks in place with a “Click.” To remove the battery, turn the radio off and remove any protective cases.
FCC ID: AXI11154620 IC: 10239A-11154620 Before You Begin proper positioning of the battery pack. If charging with the transceiver attached, turn the transceiver off. The antenna jack should be at the left side when viewing the charger from the front. If the battery pack is inserted correctly, the LED indicator will glow red. A fully-discharged battery pack will charge completely in 1.5 - 3.0 hours (depending on the battery pack being charged).
FCC ID: AXI11154620 IC: 10239A-11154620 Before You Begin Belt Clip Installation and Removal To install the Belt Clip: align the Belt Clip to the groove of the Battery pack, then press the Belt Clip downward until it locks in place with a “Click.” To remove the Belt Clip: use a flat head screw driver to press the Belt Clip Tab away from the battery pack to unlock the Belt Clip, then slide the Belt Clip upward to remove it. MIC/SP CAP Installation Install the MIC/SP cap with the supplied screws.
FCC ID: AXI11154620 IC: 10239A-11154620 Note EVX-539 Operating Manual 7
FCC ID: AXI11154620 IC: 10239A-11154620 Controls & Connectors VOL (Volume)/PWR (Power) Knob LED Indicator (Programmable) Default settings are: Steady Red: Transmitting in progress (Analog) Steady Blue: Transmitting in progress (Digital) Blinking Green: Busy Channel Steady Green: Tone Squelch in defeated condition CH (Channel) Selector Antenna Jack TOP SEL (Top Select) Key LCD (Liquid Crystal Display) 16-Button DTMF Keypad PTT Switch SIDE-1 Button SIDE-2 Button 1 2 3 A 4 5 6 B 7 8 9 C 0
FCC ID: AXI11154620 IC: 10239A-11154620 LCD Icons & Indicators : “Scan” is enabled : “Priority Scan” is activated “Dual Watch” is activated “Audio Compander” is activated Low Transmit Power Mode “On” Option SW (Key Function) is activated “CALL” Indicator Receiver Monitor “Talk-Around” is enabled Battery Indicator Priority-2 Channel Group Number “Privacy” or “Encryption” is activated “Group Scan” is enabled RSSI Indicator (four steps) 8-character Alpha-numeric Display “VOX” is activated EVX-539 Operat
FCC ID: AXI11154620 IC: 10239A-11154620 Preliminary Steps Operation Install a charged battery pack onto the transceiver, as described previously. Screw the supplied antenna onto the Antenna jack. It is not recommended to operate this transceiver without an antenna connected. If you have a Speaker/Mi crophone, we recommend that it not be connected until you are familiar with the basic operation of the EVX-539. Refer to page 11 for more information about Speaker/Microphone usage.
FCC ID: AXI11154620 IC: 10239A-11154620 Operation Rotate the VOL/PWR knob to set the volume level. If no signal is present on the analog channel, press and hold in the SIDE-1 button (under the PTT switch) more than 2 seconds; background noise will now be heard, and you may use this to set the VOL/PWR knob for the desired audio level. Press and hold the SIDE-1 button more than 2 seconds (or press the SIDE-1 button twice) to quiet the noise and resume normal (quiet) monitoring.
FCC ID: AXI11154620 IC: 10239A-11154620 Operation of the Speaker/Microphone on the radio; secure the connector pin using the screws supplied with the Speaker/Microphone. Hold the speaker grille up next to your ear while receiving. To transmit, press the PTT switch on the Speaker/Microphone, just as you would on the main transceiver’s body, and speak into the microphone on a normal voice level. Note 1): Save the original plastic cap and its mounting screws.
FCC ID: AXI11154620 IC: 10239A-11154620 Advanced Operation Programmable Key Functions The EVX-539 provides the nine programmable function (PF) keys: TOP SEL, SIDE-1, SIDE-2, [A], [B], [C], [D], [Ý ] and [#] keys. These PF keys can be customized, via programming by your Vertex Standard dealer, to meet your communications/network requirements. The possible PF key programming features are illustrated on the next page, and their functions are explained beginning after page 16.
FCC ID: AXI11154620 IC: 10239A-11154620 Advanced Operation Function None Monitor Monitor -MomentarilyDimmer Low Power Privacy / Encryption SET SQL OFF SQL OFF -MomentarilySQL Set Beep Off AF Min Volume CH Announcement Whisper VOX VOX Set VOX Anti-Trip Emergency Lone Worker Group Up Group Down Channel Up Channel Down Speed Channel Up Speed Channel Down RPI-2 Set PRI-2 Disable PRI-2 Direct CH 1 Direct CH 2 Direct CH 3 Direct CH 4 Direct CH Entry Scan Group Scan Dual Watch FM-Scan 14 TOP SEL / / /--/ / / /
FCC ID: AXI11154620 IC: 10239A-11154620 Advanced Operation Function Scan Set Group Scan Set TA Scan Talk Around Reset Call 1 Call 2 Call 3 Call 4 Call 5 Code Up Code Down Code Set Speed Dial DTMF Code Set Call Status Set Status Up Status Down Status Check Duty ID Check ARTS Login TX Save Disable Lock TOP SEL / / / / / / / / / / / / / / / / / / / / / / / / / SIDE-1 / / / / / / / / / / / / / / / / / / / / / / / / / EVX-539 Operating Manual Programmable Key (Press Key / Press and Hold Key) [A] [B] [C] SID
FCC ID: AXI11154620 IC: 10239A-11154620 Advanced Operation Description of Operating Functions Monitor Press, (or press and hold), the assigned PF key to cancel any signaling features; the LED indicator will glow with a pre-defined color (Factory default: green). Monitor -Momentarily- Cancel any signaling features while pressing the assigned PF key. Dimmer Press, (or press and hold), the assigned PF key to select the brightness level of the display and keypad. Available selections are four levels.
FCC ID: AXI11154620 IC: 10239A-11154620 SQL OFF Advanced Operation Press, (or press and hold), the assigned PF key to open the SQL to hear background noise (unmute the audio). SQL OFF -Momentarily- Opens the SQL to hear background noise (unmute the audio) while pressing the assigned PF key. SQL SET You can manually adjust the squelch level using this function: Press, (or press and hold), the assigned PF key. A tone will sound, and the current squelch level will appear on the display.
FCC ID: AXI11154620 IC: 10239A-11154620 Whisper Advanced Operation Press, (or press and hold), the assigned PF key, the display indicates “WHISP ON” briefly, and increase the microphone gain; thus you can speak in a low voice (whisper) temporarily. Press again, (or press and hold again), the assigned PF key, the display indicates “WHISP OFF” briefly, and resume normal microphone gain. VOX Press, (or press and hold), the assigned PF key, the display indicates “VOX O.
FCC ID: AXI11154620 IC: 10239A-11154620 Lone Worker Advanced Operation Press, (or press and hold), the assigned PF key, the display indicates “L-WK ON” briefly, and activates the Lone Worker feature. The Lone Worker feature is designed to emit an alarm for 30 seconds when the Lone Worker Timer (programmed by your Vertex Standard dealer) has expired. Press again, (or press and hold again), the assigned PF key, the display indicates “L-WK OFF” briefly, and the Lone Worker feature is disabled.
FCC ID: AXI11154620 IC: 10239A-11154620 Direct CH Entry Advanced Operation You can recall the desired channel directly using this function: Press, (or press and hold), the assigned PF key. A tone will sound, and the current group/channel will appear on the display. Enter the desired group number (two digits) and channel number (two digits) from the keypad ([0] - [9] key). Press the [D] key to store the new setting.
FCC ID: AXI11154620 IC: 10239A-11154620 Group Scan Advanced Operation The Scanning feature is used to monitor multiple channels programmed into the transceiver. While scanning, the transceiver will check each channel of the programmed group for the presence of the signal, and will stop on a channel if a signal is present. Press, (or press and hold), the assigned PF key, the display indicates “GRP SCAN” briefly, and activate the scanning on the selected groups.
FCC ID: AXI11154620 IC: 10239A-11154620 FM Scan (Follow-Me Scan) Advanced Operation The FM Scan feature checks a user-assigned priority channel regularly as you scan other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available channels) are designated for “Scanning”, the user may nonetheless assign Channel 2 as the “user-assigned” priority channel via the FM Scan.
FCC ID: AXI11154620 IC: 10239A-11154620 Advanced Operation hold), the assigned PF key again (the “” icon will disappear from the display). TA Scan Press, (or press and hold), the assigned PF key to toggle the TA (Talk Around) scan feature “On” and “Off”. While TA scan is proceeding, the transceiver will search both the transmit and receive frequencies (the “ ” icon will blink on the display).
FCC ID: AXI11154620 IC: 10239A-11154620 RESET Advanced Operation Press (or press and hold) the assigned PF key to reset the RFC (Ready for Communication) condition. Call 1 to Call 5 Press, (or press and hold), the assigned PF key to send a pre-defined 2-tone Sequential Tone Group (on an analog channel) or a pre-defined Digital Contact List (on a digital channel). Code Up/Down Press, (or press and hold), the assigned PF key to select a 2-Tone or 5-Tone encode code from the preprogrammed encode list.
FCC ID: AXI11154620 IC: 10239A-11154620 Call Advanced Operation Press, (or press and hold), the assigned PF key to send a 2-tone or 5-tone sequential tone. Status Set You can change the 5-tone status code using this function: Press, (or press and hold), the assigned PF key to change the 5-tone status code. Enter the 5-tone status code directly from the keypad ([0] - [9] key). Press the [D] key to store the new number to the 5-tone status code.
FCC ID: AXI11154620 IC: 10239A-11154620 ID Check Advanced Operation This function allows logged ID of the DTMF Signaling and 5-tone Signaling to be reviewed and relayed (5-tone Signaling only) to a specific station: Press, (or press and hold), the assigned PF key to display the logged ID of the DTMF Signaling and 5-tone Signaling. Press the [A] key to select the category (“DTMF Signaling” or “5-tone Signaling”) to be reviewed, then press the SIDE-1/SIDE-2 buttons to select the ID.
FCC ID: AXI11154620 IC: 10239A-11154620 TX Save Disable Advanced Operation The Transmit Battery Saver helps extend battery life by reducing transmit power when a very strong signal from an apparently nearby station is being received. Under some circumstances, though, your hand-held radio may not be heard well at the other end of the communication path, and high power may be necessary at all times.
FCC ID: AXI11154620 IC: 10239A-11154620 LOCK In order to prevent accidental channel change or inadvertent transmission, various aspects of the CH Selector knob, Programmable keys, and PTT switch may be locked. The precise lockout configuration is programmed by your Dealer. To locked out the key locking, turn the radio off. Now, press and hold the PTT and SIDE-2 key while turning the radio on again. To cancel locking, repeat this process.
FCC ID: AXI11154620 IC: 10239A-11154620 User Set Mode The EVX-539 includes a “User Set” (Menu) Mode which allows the user to define or configure various settings, such as Squelch, Display contrast, etc. To activate the “User Set” (Menu) Mode: Press the assigned PF key assigned to the “SET” function. Select the User Set Mode item you wish to change using the [ A ] / [ B ] keys, then use the SIDE-1/SIDE-2 keys to adjust the setting of the selected item.
FCC ID: AXI11154620 IC: 10239A-11154620 FNB-V133LI-UNI FNB-V134LI-UNI CD-58 PA-55 MH-360S MH-450S MH-37A4B MH-66A4B MH-81A4B ATV-16A ATV-16B ATV-16C ATV-16XL ATU-16B ATU-16C ATU-16D ATU-16F ATU-16BS ATU-16DS CN-2A 30 Optional Accessories 7.4V, 1380 mAh Li-Ion Battery Pack 7.
FCC ID: AXI11154620 IC: 10239A-11154620 Note EVX-539 Operating Manual 31
FCC ID: AXI11154620 IC: 10239A-11154620 Warranty Policy Vertex Standard warrants, to the original purchaser only, its Vertex Standard manufactured communications products against defects in materials and workmanship under normal use and service for a given period of time from the date of purchase. Limited Warranty Details: North America customers (USA and Canada): http://www.vertexstandard.com/lmr/warranty-term.aspx Customers outside of North America: contact the authorized dealer in your country.
FCC ID: AXI11154620 IC: 10239A-11154620 The AMBE+2TM voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment.
FCC ID: AXI11154620 IC: 10239A-11154620 Vertex Standard LMR, Inc. Copyright 2013 Vertex Standard LMR, Inc. All rights reserved. No portion of this manual may be reproduced without the permission of Vertex Standard LMR, Inc.