Encore Multi-Fuel Heater Model 2547CE Homeowner’s Installation and Operating Manual 0971 Encore Multi-Fuel cover 9/02 Safety Notice: If this appliance is not properly installed, operated and maintained, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury or even death. Contact local building officials about restrictions and installation inspection requirements in your area.
Encore Multi-Fuel Heater Welcome Congratulations on your choice of a Vermont Castings Encore Multi-Fuel Heater. With this purchase you have made a commitment to make the hearth a place of warmth, beauty, and comfort in your home. At MHSC, we share that joy and appreciation for the hearth. You may be assured that your cast-iron Vermont Castings stove has been made with the utmost care and will provide you with many years of service.
Encore Multi-Fuel Heater Specifications Encore Multi-Fuel, Model 2547CE Wood Smokeless Fuel2 1 Nominal heat output 12.3 kW 7.7 kW1 (42,000 BTU/hr) (26,270 BTU/hr) Minimum flue draught 12 Pa 12Pa (0.048” WG) (0.048”WG) Mean flue gas temp 291°C (556°F) 267°C (513°F) Efficiency (space heating) 71.6% 66.7% Fuel size/type up to 510 mm (20”) Smokeless coal Flue mass gas flow 12.0 g/s 10.4 g/s CO Emissions (@ 13% O2) 7900 ppm 3200 ppm Area Heated............................... 129 sq. m (1400 sq.ft.
Encore Multi-Fuel Heater Installation • Your stove and chimney connector will be far • • enough from combustible material to meet all clearance requirements. The hearth is large enough and is constructed properly to meet all requirements. You have all necessary permits from local authorities. Your local building official is the final authority for approving your installation as safe and determining that it meets local and state codes.
Encore Multi-Fuel Heater What Kind of Chimney to Use Prefabricated Chimneys You must connect the Encore Multi-Fuel to a code-approved masonry chimney with a flue liner, to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney. (Fig. 3) The chimney and chimney connector must be in good condition and kept clean. These should be an internal diameter of 150 mm (6”) and be of the twin wall insulated construction that has been approved for solid fuel use (e.g.
Encore Multi-Fuel Heater Flue Pipes with a spigot and socket joint should be fitted with the socket facing upwards, to contain condensates and moisture within the flue. Joints should be made gas tight using proprietary jointing accessories, or, where appropriate, by packing joint with noncombustible rope and fire cement. Double-wall connectors must be tested and listed for use with solid-fuel burning appliances. Single-wall connectors should be made of 24 gauge or heavier steel.
Encore Multi-Fuel Heater Chimney Flue Elbow Flue Liner Without a thimble, a suitable length of chimney connector can be extended through the breech to the inner face of the flue liner, and cemented securely in place. Additional pieces of connector are then attached with sheet metal screws. Fireplace Installations Slip Pipe The chimney connector may be connected to the chimney above the fireplace opening or through the fireplace.
Encore Multi-Fuel Heater • The fireplace damper must be sealed to prevent room air from escaping up the flue. However, it must be possible to reopen the damper to inspect or clean the chimney. Through the Fireplace If your fireplace opening height is at least 26¹⁄₂" (675mm), you may install an Encore Multi-Fuel through the opening using a “positive connection” kit, available from your local dealer. These positive connection kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig.
Encore Multi-Fuel Heater Costructional Hearth Dimensions as below At least 150 mm or to a suitable heat resistant wall Appliance Appliance Doors Doors Hearth Surface Free of Combustible Material At least 150 mm Perimeter should be clearly marked e.g. edge of superimposed hearth Perimeter should be clearly marked e.g. edge of superimposed hearth At least 300 mm a) Fireplace recess b) Free standing Fig. 10 Noncombustible hearth surface dimensions.
Encore Multi-Fuel Heater in section 2 of Document J, all installations must comply with these requirements or with the relevant National or local building standards. Clearances to timber framed (studded) walls are included below. There are no specific minimum clearances to solid noncombustible surfaces (e.g. the sides and rear of Inglenook fire openings constructed from solid masonry) other than to allow safe access to the controls of the stove.
Encore Multi-Fuel Heater Assembly Set Up Your Stove Cast iron stoves are heavy, and it will take two to four people to move your Encore MF into position. Wash the protective coating of oil from the griddle with soap and water. Dry the griddle thoroughly and apply a light coating of vegetable oil to season the surface and help prevent rust. Remove all packing materials from inside the stove. Install the Optional Bottom Heat Shield 1.
Encore Multi-Fuel Heater Operation 7!2.).' A Damper Directs Air Flow Within the Stove (/4 ',!33 7),, #!53% "52.3 $/ ./4 4/5#( ',!33 5.4), #//,%$ .%6%2 !,,/7 #(),$2%. 4/ 4/5#( ',!33 The Encore Multi-Fuel Controls Two controls regulate the performance of the Encore: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove or directly up the vent. The damper handle on the left side of the stove opens and closes the damper to direct air flow within the stove.
Encore Multi-Fuel Heater Two Ways to Add Fuel The Encore’s griddle lifts for convenient top-loading of fuel, and is the easiest way to regularly add fuel. In addition, however, the front doors open for adding an occasional log to a fire. The Encore is not approved in Europe for operation with the front doors open. To open the front doors, insert the handle into the door latch stub and turn it to the left and up. (Fig.
Encore Multi-Fuel Heater on Page 17 to see how the size, type, and location of your chimney will affect your stove operation. When thermometer readings drop below 175° C (350° F) it’s time to adjust the air control for a higher burn rate or to reload the stove. A temperature reading over 385° C (750° F) is a sign to cut back on the air supply to slow the burn rate. Your Encore will accept a duct to deliver outside air for combustion.
Encore Multi-Fuel Heater burning wood, continue adding split logs of this size to the briskly-burning fire until there is a glowing ember bed at least 76 mm (3”) deep. If burning coal, begin adding small amount directly on the kindling to establish a burning coal pile. 5. Close the damper when the griddle temperature reaches 230° C (450° F). 6. Adjust the air control for your desired heat output. Refuel While the Embers Are Still Hot ST263 Fig. 24 Start fire with newspaper and dry kindling. up” a fire.
Encore Multi-Fuel Heater recommended only to add briquettes to the level of the front grate. 4. Close the damper. 5. When the surface temperature reaches 230° C (450° F), adjust the air control for the amount of heat you desire. NOTE: If the remaining coal bed is relatively thick and if wood fuel is well seasoned, it is possible to add fresh fuel (smaller pieces first), close the door and damper, and reset the primary air thermostat for the desired heat output.
Encore Multi-Fuel Heater Draft Management A stove is part of a system, which includes the chimney, the operator, the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well. Wood stove or insert operation depends on natural (unforced) draft. Natural draft occurs when the smoke is hotter (and therefore lighter) than the outdoor air at the top of the chimney.
Encore Multi-Fuel Heater Creosote Creosote is a by-product of slow wood-burning. It’s an organic tar that can condense in the flue if it’s dense in the smoke, and slow-moving, and cools off to less than 143° C (290° F). Condensed creosote is volatile, and can generate chimney fires if it gets hot enough.
Encore Multi-Fuel Heater Maintenance Below you will find important information on general care, inspection and maintenance of your Vermont Castings stove. Should it become necessary, use only replacement parts recommended by your authorized dealer Keep Your Stove Looking New and Working Its Best Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure.
Encore Multi-Fuel Heater 3. Replace the doors on the stove. Remove the griddle so you can reach in through the opening to position the manifold. Move the door manifold as high as possible without actually touching the upper air manifold, and as far toward the center of the stove as possible without hitting the door manifold on the other door. Tighten all screws. 4. Open and close the doors to check that the door manifold does not interfere with either of the other manifolds. Adjust as necessary. 3.
Encore Multi-Fuel Heater Pawl Small Locking Nut Striker Screw Large Locking Nut ST560 Fig. 33 Remove gasket then clean channel with wire brush. ST560 Set Screw Handle Stub ST531 Fig. 32 Turn the door latch striker screw in or out to tighten or ST531 loosen the door latch. Door Pawl Replace the Stove Gaskets as Needed 11/00 3. Determine the correctRemove length of the appropriate-sized gasket gasket by laying it out in 11/30/00 the channel.
Encore Multi-Fuel Heater Permanent Encore Multi-Fuel Gaskets Other gaskets form seals between non-moving parts, but these are not subject to the same wear and deterioration as gaskets on moving parts. It is unlikely that you will ever need to replace these gaskets unless the involved parts are disassembled and then put back together. If this is the case, the job should be done only by a qualified service technician.
Encore Multi-Fuel Heater 1 2 5 6 7 10 8 4 12 3 13 13 62 10 14 11 25 9 15 66 11 27 26 16 23 9 24 61 20 19 22 18 29 31 32 54 28 30 65 53 33 17 59 34 21 57 52 64 56 55 36 35 33 38 37 48 39 50 49 41 40 43 45 60 42 63 52 64 51 58 44 57 47 46 0971 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Encore Multi-Fuel Heater Encore Multi-Fuel Heater Model 2547CE (continued) Item Description Part Number 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36.
Encore Multi-Fuel Heater Encore Multi-Fuel Heater Model 2547CE (continued) Shell Enamel Parts - Encore Multi-Fuel Model 2547CE Part Name Classic Green Moonlight Sand Red Blue Top 1308618 2318618 2378618 1328618 2328618 1338618 Left Side 1308623 2318623 2378623 1328623 2328623 1338623 Right Side 1308619 2318619 2378619 1328619 2328619 1338619 Flue Collar 1304280 2314280 2374280 1324280 2324280 1334280 Front 1308635 2318635 2378635 1328635 2328635 1338635 Ashlip 1307406 2317406 2377406 1327406 2327406 1337
Encore Multi-Fuel Heater 26 2000971
Encore Multi-Fuel Heater Warranty Limited 3 Year Warranty MHSC warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly, handles, glass door panels, cement, and gasketing shall be warranted as described below. MHSC will repair or replace, at its option, any part found to be defective upon inspection by a MHSC Authorized Dealer.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.