Operating Guide
ITEM #0140599
MODEL #TM-055
IN-WALL
COUNTDOWN TIMER
1. Wiring Layout
* Tools required
2. Installation
1. Turn OFF power at the main in-wall junction box.
2. Using wire nuts (B), connect each line
coming out of the timer (A) to the wires coming
out from the in-wall junction box. Connect the
black wire to the power-in wire and the red wire to
the power-out wire.
3. Carefully put the connected wires and the timer
unit into wall box.
4. Secure the timer (A) to the wall box using the
screws (C).
Call customer service at 1-866-994-4148,
8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
WARRANTY
TROUBLESHOOTING
• For information on product warranty please call
customer service at 1-866-994-4148, 8 a.m. - 6 p.m.,
EST, Monday - Thursday, 8 a.m. - 5 p.m., EST,
Friday.
• This product is guaranteed to be free of defects for
a limited period of one year form the date of
purchase.
• If the product suddenly malfunctions and is not
damaged by external factors or personal reasons
within the one year warranty limit from the day of
purchase, the product maybe considered for repair.
If the product is damaged due to natural disaster like
fire, lightning, flood, hurricane, etc., the product will
not be considered for repair.
PROBLEM POSSIBLE
CAUSE
CORRECTIVE
ACTION
The
attached
device turns
off
immediately
after being
turned on.
The timer is
wired incorrectly.
Disconnect wires,
remove timer,
re-install per the
instruction manual.
If problem persists,
contact certified
electrician.
HELPFUL TIPS
SAFETY INFORMATION
CARE AND MAINTENANCE
• To avoid fire, shock, or death, turn off power at circuit
breaker and test that power is off before wiring.
Please read and understand this entire manual before
attempting to assemble, operate or install the product.
RATINGS:
20 A, 125 V general purpose
10 A, 250 V general purpose
10 A, 277 V general purpose
1,875 W tungsten, 15 A resistive
1 HP, 125 V AC
2 HP, 250 V AC
125 V AC, 500 W electronic ballast
• Store indoors in dry location.
• Installation by a licensed electrician is recommended.
Installation and use of this equipment should be in
accordance with provisions of the U.S. National
Electrical Code, applicable local codes and pertinent
industry standards.
• These timers are not to be used in precision timing
applications when inaccurate timing could have
dangerous consequences such as with sun lamps or
in tanning booths.
• Do not use to control receptacles.
• For indoor use only unless installed in a, NEMA type
3R enclosure.
• Use only copper wire.
• High Voltage – Disconnect power supply before
servicing.
• The device is to be used in conjunction with a
UL Listed Cover Plate for field installation.
CAUTION
3. Set the countdown time
1. Turn the knob switch clockwise until the slot of
knob aligns with dial mark of cover plate.
2. Turn on the main power.
You may turn OFF the load at any time while it is ON
by simply moving the knob switch counterclockwise to
the OFF.
To turn the load ON again, just turn switch to the
desired time.
The timer may be reset at any time by turning the load
OFF and back the desired time.
INSTALLATION INSTRUCTIONS
1. Knob Switch
2. Black Wire
3. Red Wire
4. Mounting screws
1
3
1
2
4
4
PACKAGE CONTENTS
A B
C
PART DESCRIPTION QUANTITY
1
2
A
B
Timer
Wire nuts
2C
Mounting screws
OFF
Turn
Past
10
20
30
40
50
60
minutes
AB13549 Printed in China
3.3833” 3.3833” 3.3833” 3.3833” 3.3833” 3.3833”
Item: 140599(TM-055-1)
Page size: 11”(W)x8.5”(H)
Dieline: ______
Layout area: ______
Version Submitted by KAB: R5
Submission date: 2013/07/02
11”
8.5”
Page 1 Page 2
11”
8.5”
ITEM #0140599
MODEL #TM-055-1
INSTALLATION INSTRUCTIONS
IN-WALL
COUNTDOWN TIMER
1. Wiring Layout
2.Installation
1. Turn OFF power at the main in-wall junction box.
2. Using wire connectors, connect each lines
coming out of the timer to the wires coming out
from the in-wall junction box. Black wire is
connected with the wire of power-in, Red wire is
power-out.
3. Carefully put the connected wires and the timer
unit into wall box
4. Screw the unit with two mounting screws D into
the wall box.
Call customer service at 1-866-994-4148,
8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
A. Knob Switch
B. Black Wire
C. Red Wire
D. Mounting screws
HELPFUL TIPS
SAFETY INFORMATION
CARE AND MAINTENANCE
• To avoid fire, shock, or death, turn off power at circuit
breaker and test that power is off before wiring.
Please read and understand this entire manual before
attempting to assemble, operate or install the product.
RATINGS:
20 A, 125 V general purpose
10 A, 250 V general purpose
10 A, 277 V general purpose
1875W tungsten, 15A resistive
1 HP, 125 VAC
2 HP, 250 VAC
125Vac 500W electronic ballast
• Store indoors in dry location.
• Installation by a licensed electrician is recommended.
Installation and use of this equipment should be in
accordance with provisions of the U.S. National
Electrical Code, applicable local codes and pertinent
industry standards.
• These timers are not to be used in precision timing
applications when inaccurate timing could have
dangerous consequences such as with sun lamps or
in tanning booths.
• Do not use to control receptacles.
• For indoor use only unless installed in a, NEMA type
3R enclosure.
• Use only copper wire.
• High Voltage – Disconnect power supply before
servicing.
• The device is to be used in conjunction with a
UL Listed Cover Plate for field installation.
CAUTION
2. Set the countdown time
1. Turn the knob switch clockwise until the slot of
knob aligning with dial mark of cover plate.
2. Turn on the main Power.
You may turn OFF the load at any time while it is ON
by simply moving the knob switch counterclockwise to
the OFF.
To turn the load ON again, just turn switch to the
desired time.
The timer may be reset at any time by turning the load
OFF and back the desired time.
1
C
A
B
D
D
xxxxxx