SDS

1480043
-
Celxpert Lithium Ion Battery A
-
4a
Revision Date
02-Oct-
2018
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page
5
/
13
protective equipment as required. Evacuate personnel to safe areas. Attention! Corrosive
material. Keep people away from and upwind of spill/leak.
Other Information
Refer to protective measures listed in Sections 7 and 8.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Take off contaminated clothing and wash before
reuse. In case of insufficient ventilation, wear suitable respiratory equipment. Handle
product only in closed system or provide appropriate exhaust ventilation. Do not eat, drink
or smoke when using this product.
Conditions for safe storage, including any incompatibilities
Storage Conditions Keep containers tightly closed in a dry, cool and well-
ventilated place. Keep out of the reach
of children. Store locked up. Protect from moisture. Store away from other materials.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Lithium Cobalt Oxide (CoLiO2)
12190-79-3
TWA: 0.02 mg/m
3
-
Graphite
7782-42-5
TWA: 2 mg/m
3
respirable
particulate matter all forms
except graphite fibers
TWA: 15 mg/m
3
total dust
synthetic
TWA: 5 mg/m
3
respirable
fraction synthetic
(vacated) TWA: 2.5 mg/m
3
respirable dust natural
(vacated) TWA: 10 mg/m
3
total
dust synthetic
(vacated) TWA: 5 mg/m
3
respirable fraction synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m
3
TWA: 2.5 mg/m
3
respirable
dust
Phosphate(1-), hexafluoro-,
lithium
21324-40-3
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
(vacated) TWA: 2.5 mg/m
3
IDLH: 250 mg/m
3
F
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
IDLH: 100 mg/m
3
dust, fume
and mist
TWA: 1 mg/m
3
dust and mist