User guide
USER GUIDE
Extended Non-Use 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Extended Non-Use
STORAGE, VACATION AND MOVING
If not using the unit for an extended period, or otherwise
stored, follow these steps completely:
WARNING
!
Electrical Shock Hazard. Disconnect power
before servicing. Before operating, replace all
panels. Failure to do so may result in electrical
shock or death.
NOTICE
If the ambient temperature is expected to drop
below 50°F (10°C), turn off and unplug unit.
1. Remove all consumable content from the unit.
2. Disconnect the power cord from its outlet, and leave it
disconnected until the unit is returned to service.
3. If ice is on the evaporator, allow ice to thaw naturally.
CAUTION
!
DO NOT use an ice pick or other sharp
instrument to help speed up defrosting. These
instruments can puncture the inner lining or
damage the cooling unit. DO NOT use any type of
heater to defrost. Using a heater to speed up
defrosting can cause personal injury and
damage to the inner lining.
4. Clean and dry the interior of the cabinet. Ensure all
water has been removed from the unit.
5. During periods of non-use, the cabinet must remain
open to prevent formation of mold and mildew. Open
door a minimum of 2 in. (5 cm) to provide the
necessary ventilation.