Operator's Manual
g192607
Figure45
1.Section-bypassshutoffvalve(closedposition)
5.Formachinesoperatedintheapplication-rate
mode,ensurethatthesection-bypassshutoff
valveisclosed(Figure45).
6.Engagetheparkingbrakeandstarttheengine.
Note:Allowtheenginetowarmfor10minutes.
7.Formachinesoperatedintheapplication-rate
mode,performthestepsinUsingtheT est
Speed;refertotheSoftwareGuideforthe
MultiPro5800-Dand5800-Gturfsprayerswith
ExcelaRatespraysystem.
Note:Setthesimulatedtestspeedbetween4
km/h(2mph)and14km/h(9mph).
PerformingaCatchTest
1.Setthespraysectionswitch(es)totheON
positionforthesection(s)thatyouaretesting.
2.SetthethrottletotheFASTposition.
3.SetthemastersectionswitchtotheONposition.
4.Performa15-secondcatchtestat1oftheactive
spraynozzles.
g193177
Figure46
5.Shutoffthemastersectionswitch,setthe
throttletotheslowposition,shutoffthespray
pump,andshutofftheengine.
6.Setthegraduatedcontaineronalevelsurface
andnotetheuidvolume(Figure47).
Important:Whenyouarereadingthe
graduatedcontainer,youmustsetthe
containeronalevelsurface.
Important:Whenyouarereadingthe
graduatedcontainer,readtheuidvolumein
thegraduatedcontaineratthelowestpoint
oftheuid-surfacecurve.
Important:Smallerrorsreadingtheuid
volumeinthegraduatedcontainerwill
signicantlyimpacttheaccuracyofthe
sprayercalibration.
g193829
Figure47
1.Highestpointofthe
uid-surfacecurve(donot
measurehere)
3.Levelsurface
2.Lowestpointofthe
uid-surfacecurve
(measurehere)
7.Comparethevolumeofwaterinthegraduated
containerwiththenozzlevolumeinthe
15-secondcatchtesttable.
15-SecondCatchTestTable
NozzleColor
Milliliters
collectedin15
seconds
Ouncescollected
in15seconds
Yellow1896.4
Red37812.8
Brown47316.0
Gray
56719.2
White
757