User's Manual

Table Of Contents
InterSense Doc. No. 072-00105-0I07 Rev. 4.2
IS-900 User Guide Page 24 of 177
1.5.5. Wireless MicroTrax Modules
All MicroTrax tracked stations can be operated without cabling to the IS-900 processor by using
the IS-900 Wireless Modules. The Wireless Modules have two componentsa receiver
component that plugs into the IS-900 Processor and a rechargeable, battery operated transmitter
that is either integrated into the tracked station (e.g. IS-900 Wireless MicroTrax Wand), or
connected to a small, body worn transmitter that plugs directly in to the MicroTrax Station (e.g. IS-
900 Wireless MicroTrax Head Tracker).
1.5.6. OEM Tracking Devices
InterSense works with Value Added Resellers, Systems Integrators and Partners to provide
tracked devices tailored to specific applications. InterSense uses the Inter-IC bus (I
2
C) interface
to all MicroTrax devices. The I
2
C is an industry standard interface developed by Philips nearly 20
years ago to establish a simple 2-wire communication standard between a variety of IC’s and
interface devices.
By choosing this standard board level interface, OEM’s and systems integrators have the
flexibility of integrating the InterSense’s IS-900 wireless tracking technology and device interface
into custom 3D interaction devices. InterSense can assist you with the development of a custom
device, providing technical interface details and reference designs, or be contracted to develop
the custom device to your specifications. For additional information about custom system
development, call or email us at sales@intersense.com
.