WR-25 Instruction Manual Weather Report ™ Digital Weather Station WR-25 index Thank you for purchasing a Weather Report. Your package should contain a WR-25 console, wind sensor, temperature/humidity sensor, rain collector and this manual. Normal Operation When in normal operation (no buttons depressed).
WR-25 Instruction Manual C A U T I O N !! :BE EXTREMELY CAREFUL NOT TO TOUCH ANY HIGH POWER LINES DURING INSTALLATION OF THE VARIOUS SENSORS!!! The WR-25 wind direction and speed sensor is normally mounted on television type antenna masts (see Figure 1). For best results the wind sensor should be mounted at least 10 feet above the roof of the building. The higher the installation, the more accurate the readings.
WR-25 Instruction Manual OPERATION index / top FUNCTION KEYS Select The select key, when pressed at the same time as the report key, puts the unit into time/date and lunar/tide cycle set mode. When the select and scale keys are pressed at the same time, the unit enters the calibration set mode. When the select and average keys are pressed at the same time, the unit enters the printer set mode. When select and last are pressed at the same time the instrument enters rainfall history set.
WR-25 Instruction Manual English to Metric equivalents are miles per hour or Knots to Kilometers per hour, Fahrenheit to Celsius, Inches of Mercury to Millibars, Inches of rain to Centimeters of rain. Pressing the select and scale key at the same time puts the unit into calibration mode. Report Pressing the report key sends current data to the serial port. The report key, when depressed at the same time as the select key, puts the unit into its time setting function.
WR-25 Instruction Manual Press select a second time, and the month will be displayed (i.e., 1 = Jan. and 12 = Dec.). Press the maximum and minimum key to set the month. Press select a third time, and the day of the month (1-31) digits light. Press the maximum to advance the date and minimum to retard the date. Press select a fourth time, and the day of the week is displayed (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, and 7 = Saturday.
WR-25 Instruction Manual Press select a fifth time (note the colon between the hours and minutes), and the unit will display the time in military hour style. Press the maximum button to advance the hour or minimum to retard the hour. Press select a sixth time (note the colon between the hours and minutes), and the unit will display minutes. Press the maximum or minimum buttons. Press select a seventh time (note only the right two digits); the unit will display seconds.
WR-25 Instruction Manual Press select a tenth time (the single dot is now located at the top, between the hour and minute); the peak of the cycle hour (usually high tide) will be displayed. Change as desired. Press select an eleventh time (the single dot remains at the top between the hour and minute), and the minutes of the peak hour will be displayed. Change as desired. Press select a twelfth time and the unit will return to normal display mode.
WR-25 Instruction Manual Press select a second time and the unit displays the indoor temperature. Press the maximum or minimum key to enter the actual temperature. Press select a third time - the unit displays the outdoor temperature. Press the maximum or minimum key to enter the actual temperature. Press select a fourth time, and the unit displays barometric pressure. Press the maximum or minimum key to enter the actual barometric pressure. Texas Weather Instruments, Inc.
WR-25 Instruction Manual Press select a fifth time, and the unit displays in the rainfall window: 0, 1, 2, or 3. 2 is the normal display. Press the maximum or minimum key to enter the proper number (see calibration reference for more information). Press select a sixth time; the unit will display in the rainfall window a reading ranging from .01 to .1. Press the maximum or minimum button to enter the proper number. Press select a seventh time - the unit displays wind direction.
WR-25 Instruction Manual Press select a third time, and the minimum/maximum and form feed options 0 through 7 may be selected as illustrated in the table below: SETTING MIN/MAX 0 1 2 3 4 5 6 7 FORM FEED RAIN RATE OFF ON OFF ON OFF ON OFF ON OFF OFF OFF ON OFF OFF OFF ON OFF OFF OFF OFF ON ON ON ON When rain rate is off, term rain is substituted. Press select a fourth time to select the baud rate of the serial output. Press the maximum and minimum keys to change the display.
WR-25 Instruction Manual V- Firmware version number S- Firmware Serial# I- Unit ID number C- Unit responds with a daily minimum and maximum of all parameters, then clears. The rainfall rate is present rather than term rain. Sample MIN 07/24/90 SW 00MPH 070F 067F 067F 054% 30.00" 00.19"D 01.38"M 00.00"R MAX 07/24/90 SSE 25MPH 052F 071F 092F 099% 30.06" 00.19"D 01.38"M 00.72"R c- Unit responds with a daily minimum and maximum of all parameters, then clears. The term rain is present rather than rainfall rate.
WR-25 Instruction Manual index / top The TWI_LOG program. TWI_LOG is an IBM PC software utility which enables the user with special applications to communicate and set various functions of the WRL. Insert the TWI_LOG diskette into your disk drive and type TWI_LOG then press enter. Note: TWI LOG is no longer sent with the weather stations. The TWI Cal Windows program has replaced TWI_LOG and is included with the weather station.
WR-25 Instruction Manual TWI Main Menu F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Report Output Retrieve Log Data Display Log Data Purge Log Data Display Cal Data Graphic Log Data Print Log Data Get Version again Set Date/Time Exit Program Pressing F1 enables the user to communicate with the WRL using all the commands referred to in the Communicating with the WRL (page 14) Section of this manual. Pressing F2 instructs the computer to retrieve data from the WRL and place that data in a file on the disk drive.
WR-25 Instruction Manual Inx Value Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 85 temp:aux 65 temp: inside 73 temp: outside 29.92 barometric pressure 0 elevation 0.750 MVP @ 0.0% HR 3.255 MVP @ 73.3% HR 8 wind dir. offset 2 rain inc flag 0.01 rain inc value 0.00 rain fall: daily 0.00 rain fall: monthly 0.
WR-25 Instruction Manual hours or minutes depending on the setting of the report interval units (19) 15) Report output interval LO, sets the automatic data dump interval to the RS232. Value can be in minutes or seconds depending on the setting of the report interval unites (19). 16) Report Min/Max turns on the min-max function for the log and the report output (for the printer). 17) Report end of day- sends a formfeed at midnight to the RS-232 (for the printer).
WR-25 Instruction Manual Pressing F10 will exit the program. Direct data retrieval from a DOS prompt may be accomplished by entering TWI_LOG ? /dl, where the ? equals the line of the unit as defined in the twi_com.dat file. For example entering TWI_LOG 1 /dl would access in our current setup the Green unit. Entering TWI_LOG 2 /dl would access the Red unit. After the data is retrieved the program will return to the DOS prompt.
WR-25 Instruction Manual The pin out on the RS-232interface is as follows: .DE 9 Plug Header Pin 1 Pin 1 . . . Pin 2 Pin 3 . . . Receive Data Pin 3 Pin 5 . . . Transmit Data Pin 4 Pin 7 . . . . Data Set Ready Pin 5 Pin 9 . . . Signal Ground Pin 6 Pin 2 . . . Data Terminal Ready (must be true to send data) Pin 7 Pin 4 . . . Clear to Send Pin 8 Pin 6 . . . Request Send Pin 9 Pin 8 . . . Modem Installation A modem may be used with the WR-25 for remote operations.
WR-25 Instruction Manual Normally, barometric pressure is the only item that needs to be recalibrated (adjusting for altitude). The proper local barometric pressure can be obtained from the local news. Set the barometric pressure reading you obtained from the local media by using the calibration mode function. Temperature If for some reason you suspect that the temperature is not calibrated properly, use a quality bulb thermometer with which to calibrate.
WR-25 Instruction Manual SETTING MIN/MAX 0 1 2 3 4 5 6 7 OFF ON OFF ON OFF ON OFF ON FORM FEED OFF OFF OFF ON OFF OFF OFF ON RAIN RATE OFF OFF OFF OFF ON ON ON ON When rain rate is off, term rain is substituted. Min/Max, when selected outputs at midnight the minimum and maximum value for the day. The report function must be on in order for the output to occur. This function must also be on if you want the minimum and maximum to be logged to memory.
WR-25 Instruction Manual to your area, any cycle that lasts between 1 and 99 hours may be displayed. Clearing the Memories When the clear button is depressed and held, the unit will display the date and time the instrument's memory was last cleared. In order to clear the memories, the clear and minimum button must be pushed at the same time. The items cleared are as follow: minimum and maximum, wind speed, temperature (indoor, outdoor, and aux), barometric pressure and humidity.
WR-25 Instruction Manual FCC RADIO FREQUENCY INTERFERENCE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15, Subpart B, of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, may cause interference to radio communications.
WR-25 Instruction Manual 1/6/96 Troubleshooting index / top Instrument display does not come on. Make sure receptacle has power by plugging another appliance into it. Check that the transformer is properly wired into instrument (the leads could be reversed or not seated properly). Check that the fuse is intact (.75 amp fuse inside the case). Try unplugging the transformer to reset the computer. Instrument display works but does not read correctly.
WR-25 Instruction Manual B Barometric Pressure, 20 Barometric pressure calibration, 16 baud rate, 17 C Calibration Method, 8 Calibration mode, 8 Calibration Reference, 20 Clear, 4 Clearing the Memories, 23 Comfort, 5 Command Characters, 12 Communicating with the WR-25, 12 Computer Interface, 20 Control Options, 18 D Daily rainfall history register, 17 daily rainfall register, 21 day, 17 Dewpoint, 22 F FCC RADIO FREQUENCY INTERFERENCE STATEMENT, 25 FUNCTION KEYS, 4 H Hold, 4 hours, 17 Humidity Sensor Calibr
WR-25 Instruction Manual lunar/tide cycle, 4 M Maximum, 4 Minimum, 4 minutes, 17 modem adapter, 19 Modem Installation, 19 month, 17 N Normal Operation, 1 O OPERATION, 4 Outside temperature calibration, 16 P pagoda, 2, 26 Print Set, 11 prn_day.???, 18 prn_rec.
WR-25 Instruction Manual Special Key Functions, 22 T Temperature, 20 temperature/humidity sensor, 2 Term rainfall history register, 17 tide clock, 23 Time display, 17 Time Setting Mode, 6 Trend indicators, 1 Troubleshooting twi_com.dat, 14 TWI_LOG, 13, 20 W Wind direction calibration, 16 Wind Speed scale, 17 Windchill, 5, 13 Y years, 17 TOP Texas Weather Instruments, Inc.