Datasheet
RM46L450
RM46L850
www.ti.com
SPNS184A –SEPTEMBER 2012–REVISED SEPTEMBER 2013
NOTE
For GIOx trigger sources, the connection to the MibSPI5 module trigger input is made from
the output side of the input buffer. This way, a trigger condition can be generated either by
selecting the GIOx pin as an output pin and selecting the pin to be a GIOx pin, or by driving
the GIOx pin from an external trigger source. If the mux control module is used to select
different functionality instead of the GIOx signal, then care must be taken to disable GIOx
from triggering MibSPI5 transfers; there is no multiplexing on the input connections.
Copyright © 2012–2013, Texas Instruments Incorporated Peripheral Information and Electrical Specifications 155
Submit Documentation Feedback
Product Folder Links: RM46L450 RM46L850