Datasheet
TLC1514, TLC1518
5-V, 10-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER,
SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN
SLAS252 – DECEMBER 1999
11
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
read cycle (read FIFO or read CFR) (continued)
FIFO read cycle
The first command in the active cycle after INT is generated, if the FIFO is used, is assumed as the FIFO read
command. The first FIFO content is output immediately before the command is decoded. If this command is
not a FIFO read, then the output is terminated but the first data in the FIFO is retained until a valid FIFO read
command is decoded. Use of more layers of the FIFO reduces the time taken to read multiple data. This is
because the read cycle does not generate EOC or INT nor does it carry out any conversion.
SCLK
CS
FS
SDI
INT
EOC
SDO
ID15 ID14 ID13 ID12 ID14
OD6 OD5 OD3 OD0
12 345 6
7111215
16
1
10
OD9 OD8 OD7
ID15
OD4
Command
FIFO Data
Figure 4. TLC1514/TLC1518 Continuous FIFO Read Cycle (FS = 1)
(controlled by SCLK, SCLK can stop between each 16 SCLKs)