Datasheet

DS90LV048A
SNLS045B JULY 1999REVISED APRIL 2013
www.ti.com
Functional Diagram
TRUTH TABLE
ENABLES INPUTS OUTPUT
EN EN* R
IN+
R
IN
R
OUT
H L or Open V
ID
0V H
V
ID
0.1V L
Full Fail-safe H
OPEN/SHORT or
Terminated
All other combinations of ENABLE inputs X Z
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
2 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated
Product Folder Links: DS90LV048A